To configure advance functions, simply use the 
"

F

"

 

button to set parameters. The sequential 

operations and the corresponding explanations 
are shown in the following flow-chart.

4-4 

Advance Function

6                      

Gun-Type Professional Infrared Thermometer         

SCAN

AUTO

DATA

MAX

Data Mode

MIN

EMS

Parameter Setup mode

Scan and display the 
temperature during 
measurement.

Continuously measure and 
display the temperature 
without pulling the trigger.

Activate the data record 
function when pull the trigger 
and recall the stored data by 
using      or      button.

The maximum temperature 
during one measurement.
The minimum temperature 
during one measurement.

The temperature differential 
during one  measurement.

Highest alarm temperature 
setting.
Lowest alarm temperature 
setting.

( *The parameters are adjusted 
by using       or       buttons.)

T

AVG

.

The average  temperature 
during one measurement.

LAL

HAL

Adjustable emissivity for 
better accuracy on all surfaces.

(Note: While triggering to 
record, the new data will 
replace the existing data on 
the next storage space!)

Содержание ST 653

Страница 1: ...Gun Type Professional Infrared Thermometer MODEL ST 653 Instruction Manual...

Страница 2: ...Gun Type Professional Infrared Thermometer Instruction Manual...

Страница 3: ...2 Safety symbols 3 Specifications 4 Operation Instructions Unit Diagram Advance Function 5 Techniques ofInfrared Thermometer 6 Maintenance 1 1 Features 2 1 Cautions 4 1 Quick Start 4 2 4 3 C F and Ba...

Страница 4: ...ce Air conditioner Science experiment Manufacturing processes of semiconductor technology Test terminalson circuits Food safety and processing Perform HVAC energyaudits 1 2 Applications Thank you for...

Страница 5: ...using the meter CE Certification Laser Warning Note Do not point laser directly at eye Use caution a round reflective surfaces Keep out of reach of children This instrument conforms to the followings...

Страница 6: ...99 3 C 5 F From 32 20 C 25 4 F 5 14 m 1 C 2 F 0 1 C 0 1 F 500 ms Automatically after approx 6s 9V 006P IEC6F22 NEDA1604 187g Approx 170x133x45mm 6 69 x5 23 x1 77 Laser Sight Switchable Max Min Avg T A...

Страница 7: ...s or Fahrenheit The unit will HOLD the last reading for about 6 seconds after the trigger is released the word HOLD appears Be sure to consider the target area inside the angle of vision of this instr...

Страница 8: ...w battery symbol will appear To change the 9V battery pull open the unit s handle under the trigger After replacing the battery push back and snap in place LCD Display Scan Hold Auto mode indication D...

Страница 9: ...ut pulling the trigger Activate the data record function when pull thetrigger and recall the storeddata by using or button The maximum temperature during one measurement The minimum temperature during...

Страница 10: ...the optics of the unit The FOV is the ratio of the distance from the target to the target diameter The smaller the target the closer you should be to it When the target diameter is small it is import...

Страница 11: ...Thermometer 8 6 Maintenance Cleaning the lens Blow off loose particles using clean compressed air Gently brush remaining debris away with a camels hair brush Carefully wipe the surface with a moist co...

Страница 12: ...03 Brass hard rolled polished w lines 21 70 0 04 Iron galvanized bright 0 13 Iron plate completely 20 68 0 69 Rolled sheet steel 21 71 0 66 Oxidized iron 100 212 0 74 Wrought iron 21 70 0 94 Molten i...

Страница 13: ......

Отзывы: