background image

M2MNV

P.  / 4

EM-5095 Rev.

ANALOG SWITCHING MODULE

MODEL

M2MNV

INSTRUCTION MANUAL

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If  you  have  any  problems  or  questions  with  the  product, 
please contact M-System’s Sales Office or representatives.

 PACKAGE INCLUDES:

  Signal conditioner (body + base socket) ...................... (1)

 MODEL NO.

Confirm  Model  No.  marking  on  the  product  to  be  exactly 
what you ordered.

 INSTRUCTION MANUAL

This  manual  describes  necessary  points  of  caution  when 
you use this product, including installation, connection and 
basic maintenance procedures.

POINTS OF CAUTION

 CONFORMITY WITH EC DIRECTIVES

• This equipment is suitable for use in a Pollution Degree 

2 environment and in Installation Category II, with the 
maximum operating voltage of 300V.

  Basic  insulation  is  maintained  between  signal  channel 

and  switching  command  contact.    Prior  to  installation, 
check  that  the  insulation  class  of  this  unit  satisfies  the 
system requirements.

• Altitude up to 2000 meters
• The equipment must be mounted inside a panel.
• The  equipment  must  be  installed  such  that  appropriate 

clearance and creepage distances are maintained to con-
form  to  CE  requirements.    Failure  to  observe  these  re-
quirements may invalidate the CE conformance.

 POWER INPUT RATING & OPERATIONAL RANGE

• Locate the power input rating marked on the product and 

confirm its operational range as indicated below:

  85 – 264V AC rating: 85 – 264V, 47 – 66 Hz, approx. 3 – 5VA
  100 – 240V AC rating: 85 – 264V, 47 – 66 Hz, approx. 3 – 5VA
  24V DC rating: 24V ±10%, approx. 2W
  11 – 27V DC rating: 11 – 27V, approx. 2W
  110V DC rating: 85 – 150V, approx. 2W

 GENERAL PRECAUTIONS

• Before you remove the unit from its base socket or mount 

it, turn off the power supply for safety.

 ENVIRONMENT

• Indoor use
• When heavy dust or metal particles are present in the air, 

install the unit inside proper housing with sufficient ven-
tilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -5 to +55°C     

(23 to 131°F) with relative humidity within 30 to 90% RH 
in order to ensure adequate life span and operation.

• Be sure that the ventilation slits are not covered with ca-

bles, etc.

 WIRING

• Do not install cables (power supply, signal line and switch-

ing command contact) close to noise sources (relay drive 
cable, high frequency line, etc.).

• Do  not  bind  these  cables  together  with  those  in  which 

noises are present.  Do not install them in the same duct.

 AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 10 minutes is required for 
satisfying  complete  performance  described  in  the  data 
sheet.

COMPONENT IDENTIFICATION

 FRONT PANEL CONFIGURATION

Body

Base Socket

Fixing Screw

Connection
Diagram

Specifications

Model

• Channel 2
  Status LED 2

• Channel 1
  Status LED 1

Power LED

Rugghölzli 2
CH - 5453 Busslingen

Tel. +41 (0)56 222 38 18

Fax +41 (0)56 222 10 12

[email protected]

www.sentronic.com

Produkte, Support und Service

SENTRONIC

AG

Содержание M-SYSTEM M2MNV

Страница 1: ...Operational voltage range 11 27 V ripple 10 p p max Select N for Standards Approvals code P 110 V DC Operational voltage range 85 150 V ripple 10 p p max 4 OPTIONS multiple selections Standards Approv...

Страница 2: ...Switching response time 5 msec Leakage current at open circuit 1 A Line voltage effect 0 1 over voltage range Insulation resistance 100 M with 500 V DC signal channel to switching command contact to p...

Страница 3: ...32 11 M3 SCREW 72 2 83 29 5 1 16 2 4 2x5 17x 20 MTG HOLE 6 24 deep When mounting no extra space is needed between units 21 5 85 70 5 2 78 84 3 31 10 39 DIN RAIL 35mm wide 4 16 114 4 49 4 16 Ruggh lzli...

Страница 4: ...with the input code 2 Current signal receiving resistor 50 2 Provided only with the input code 1 Current signal no receiving resistor 1 2 Not provided with the input code 3 A1 B1 channel is connected...

Страница 5: ...signal channel is switched only after all photo MOS relays turn on closed When the switching command contact is switched from OFF to ON or from ON to OFF the signal channel is switched only after all...

Страница 6: ...V Specifications are subject to change without notice Ruggh lzli 2 CH 5453 Busslingen Tel 41 0 56 222 38 18 Fax 41 0 56 222 10 12 mailbox sentronic com www sentronic com Produkte Support und Service S...

Страница 7: ...e as indicated below 85 264V AC rating 85 264V 47 66 Hz approx 3 5VA 100 240V AC rating 85 264V 47 66 Hz approx 3 5VA 24V DC rating 24V 10 approx 2W 11 27V DC rating 11 27V approx 2W 110V DC rating 85...

Страница 8: ...the upper hook at the rear side of base socket on the DIN rail and push in the lower When removing the socket push down the DIN rail adaptor utilizing a minus screwdriver and pull WALL MOUNTING Refer...

Страница 9: ...1 2 4 5 7 8 Power ON Switching command ON short Current Signal receiving resistor 50 Voltage Signal Current Signal no receiving resistor Transition ON to OFF OFF to ON Status Power ON Switching comma...

Страница 10: ...A2 1 A2 2 3 6 9 SWITCHING COMMAND SW1 INTERLOCKING SWITCHING CONTROL single pole contact U V POWER 10 11 1 7 8 2 4 5 B1 1 B1 2 A1 1 A1 2 A2 1 A2 2 3 6 9 SWITCHING COMMAND SW1 INDEPENDENT SWITCHING CON...