![Sentiotec IS1 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/sentiotec/is1/is1_instructions-for-installation-and-use-manual_1244680027.webp)
13 Technical data
Power supply
230V ~ 1N PE
Maximum switching load radiator
16A, AC1
Maximum switching load light
0,8A, AC1
Power
consumption
3W
Standby power consumption
1W
Dimensions of cover
179.5mm x 134.5mm x 10mm – see also Fig. x
Installation depth countersunk mounting 39.5mm – see also Fig. x
Wall cutout countersunk mounting
102mm x 160mm – see also Fig. y
Ambient conditions
0°C – 70°C, maximum 99% relative air humidity, non-condensing
36
99
179,5
134,5
158
39,5
48,5
102mm
160mm
max. R5mm
14 Accessories and spare parts
IR-IS-A
Adapter lead for the connection of sentiotec radiators and hotplates
IR-1P2
2-pole
T-distributor
IR-1P3
3-pole
distributor
IR-1P5
5-pole
distributor
P-ISX-FF
Film sensor incl. 3 m cable
P-ISX-FUSE
Fine fuse tray for light
O-F2
Room
sensor
Fig. 11: Dimensions
WE DO IT FIRST.
Instructions for installation and use
P. 13/14
EN
Содержание IS1
Страница 57: ...Infraroodregeling IS1 P IS1 T MONTAGE EN GEBRUIKSAANWIJZING Nederlands 36 Version 01 13 Ident Nr 50950078 NL ...
Страница 71: ...Infrarödstyrning IS1 P IS1 T MONTERINGS OCH BRUKSANVISNING svenska 36 Version 01 13 Ident Nr 50950078 SV ...
Страница 85: ...Infračervená ovládací jednotka IS1 P IS1 T NÁVOD K MONTÁŽI A POUŽITÍ česky 36 Verze 01 13 Ident č 50950078 CS ...
Страница 113: ...WE DO IT FIRST BELEŽKE APPUNTI NOTES NOTE NOTITIES str 15 16 ...
Страница 114: ...BELEŽKE APPUNTI NOTES NOTE NOTITIES WE DO IT FIRST str 16 16 ...
Страница 115: ...WE DO IT FIRST BELEŽKE APPUNTI NOTES NOTE NOTITIES str 17 16 ...