15
INSTALLATION AND OPERATION INSTRUCTIONS — PERSONAL ALARM SYSTEM
2.5
LAP Local Annunciation Panel
2.5.1
The LAP Local Annunciation Panel is an auxiliary device which permits alarm
annunciation of up to four personal alarm zones in a compact package for mounting
in a standard double-gang box. Thus, nearby personnel can be notified of an alarm
situation at the same time the alarm is indicated at the central control location.
2.5.2
The LAP indicates alarms with flashing red LED’s for the respective zones and
a beeping alert tone. Separate push-button controls (one for each zone) allow the
operator to acknowledge each alarm and silence the audio tone. A subsequent push
of the button resets the zone. Secure zones are indicated by a green LED.
Acknowledging and resetting alarms on the LAP does not affect the central control
alarm annunciation and command functions. Figure 2-4 illustrates the faceplate of
the LAP.
2.5.3
When used in a PAS 120 system, the LAP draws power and receives alarm
information from the remote alarm outputs of a PARC-3, requiring a 6 conductor
interconnecting cable. As supplied, LAP zones are labeled on their respective control
buttons as zones one through four. Custom zone designations can be easily applied
to the clear plastic front control buttons.
1
2
3
4
Figure 2-4 LAP Local Annunciator Panel