Attaching the sensor cable
FiberPatrol sensor cable is attached to the fence fabric with stainless steel cable ties.
is
an overview of the recommended cable attachment procedure.
•
Install the sensor cable on the secure side of the fence (the side opposite the threat).
•
Keep the sensor cable straight and taut while attaching it to the fence fabric.
•
Attach the cable to the fence fabric at the junction of two fence wires.
•
The maximum allowable spacing between cable ties is 60 cm (2 ft.).
•
Attach the sensor cable at both sides of each fence post approximately 30 cm (1 ft.) away from
the post.
1. Beginning approximately 30 cm away from the start point post, attach the sensor cable to the
fence at the junction of two fence wires at the specified height above ground (point a).
2. Hold the cable straight and level just past the second post and attach it to the fence at the
junction of two fence wires app. 30 cm away from the second post (point b).
3. Attach the sensor cable at the junction of two fence wires app. 60 cm past point b (point c).
4. Attach the sensor cable at the junction of two fence wires app. 30 cm before the second post
(point d).
5. Attach the sensor cable at 60 cm intervals on the first fence panel (points e, f, g).
6. Hold the cable straight and level just past the third post and attach it to the fence at the
junction of two fence wires app. 30 cm away from the third post (point h).
7. Attach the sensor cable at the junction of two fence wires app. 60 cm past point h (point i).
8. Attach the sensor cable at the junction of two fence wires app. 30 cm before the third post
(point j).
9. Attach the sensor cable at 60 cm intervals on the second fence panel (points k, l).
10. Proceed along the perimeter, attaching the cable to the fence one panel at a time.
Attaching the sensor cable at protected swinging gates
Before attaching the sensor cable to a swinging gate, ensure that there is a sufficient amount of
sensor cable laid out to:
•
cover the gate
Figure 50 Cable installation procedure
second post
start point post
fence-mounted
third post
conduit to sensor unit
isolation loop