Page 38
FiberPatrol Site Planning & Installation Guide
•
Ensure that the minimum bend radius (dynamic and static) is not exceeded during or after
installation.
Figure 43 Cable tie spacing around corners
Figure 44 Static and dynamic bend radius limits
60 cm (2 ft.)
secure cable at any
changes in direction
with a cable tie at
each 45º point
110 mm (4.3 in.)
min. bend radius
30 cm (1 ft.)
30 cm (1 ft.)
60 cm (2 ft.)
60 cm (2 ft.)
smallest allowable bend
radius for installed sensor
cable = 110 mm (4.33 in.)
smallest allowable bend
radius when installing sensor
cable = 220 mm (8.66 in.)