background image

FUNCTION #8: RESTORE FACTORY DEFAULTS

To return a wall switch controller to its original factory default settings, follow the below steps:

1

 Enter programming mode by pressing and holding the button for at least 

6 seconds

 until the LED begins flashing 

blue only

, then release. 

2

 Press and release the unit’s pushbutton 

8 times

, wait 2 seconds, then press the button 

3 times

.

3

 To 

Execute

 the command and 

Exit

 programming mode, press and holding the button until the LED changes to 

blue

, then release. The LED will then blink white twice as confirmation of 

success. 

Note: 

To Exit without saving during any step, release button and wait until the unit double flashes blue.

FUNCTION #7: LED BEHAVIOUR

When the load controller has switched the lights off, the unit’s LED will be solid blue as a locator. To disable this locator LED functionality, follow the below steps.

SETTING #

DESCRIPTION

 2

Locator LED enabled 

(default)

3

Locator LED disabled

CHANGING THE LED BEHAVIOUR
1

 Enter programming mode by pressing and holding the button for at least 

6 seconds

 until the LED begins flashing 

blue only

, then release. 

2

 Press and release the unit’s pushbutton 

7 times

, wait 2 seconds, then press the button 

3 times 

to disable location functionality (or 2 times to enable).

3

 To 

Execute

 the command and 

Exit

 programming mode, press and holding the button until the LED changes to 

blue

, then release. The LED will then blink white twice as confirmation of 

success. 

Note: 

To Exit without saving during any step, release button and wait until the unit double flashes blue.

FUNCTION #5: RELAY ENABLE/DISABLE

If the wall switch load controller is being used as a remote switch for another load controller and not controlling a lighting load of its own, the relay can be disabled. To disable, follow the 
below steps.

SETTING #

DESCRIPTION

 2

Relay enabled 

(default)

3

Relay disabled (i.e. always closed)

DISABLING THE RELAY
1

 Enter programming mode by pressing and holding the button for at least 

6 seconds

 until the LED begins flashing 

blue only

, then release. 

2

 Press and release the unit’s pushbutton 

5 times

, wait 2 seconds, then press the button 

3 times 

to disable the relay (or 2 times to enable).

3

 To 

Save

 the setting and 

Exit

 programming mode, press and holding the button until the LED changes to 

blue

, then release. The LED will then blink white twice as confirmation of 

success. 

Note: 

To Exit without saving during any step, release button and wait until the unit double flashes blue.

CONFIGURATION SETTINGS 

(CONT.)

Содержание SWX-851 Series

Страница 1: ...40 with obstruction walls floors FREQUENCY 915 MHz ISM Band WIRELESS LINKING Simple 3 sec Push Button Process SECURITY All Wireless Data is Encrypted PHYSICAL SIZE 2 74 H x 1 68 W x 1 39 D 6 96 x 4 27 x 3 53 cm 1 Wallbox Mounting Depth WEIGHT 4 5 oz MOUNTING Single Gang Switch Box LED STATUS INDICATOR Bi color White Blue CODE COMPLIANCE These load controllers can be used to meet ASHRAE 90 1 IECC T...

Страница 2: ...ations where Neutral connection is available as well as installations where only Ground connection is present à If no neutral is present remove the white sleeve from the wire connect the now Green Yellow wire to Ground à Note either the white wire or green yellow wire must be connected The all green wire is just for safety BASIC WIRING WARNING TURN POWER OFF AT THE CIRCUIT BREAKER BEFORE WIRING LI...

Страница 3: ...troller is quickly done via the following procedure Step 1 Enter pairing mode by holding down the wall switch s button for 3 seconds until the LED starts alternating blue and white then release Step 2 At the sensor or other remote device hold down the programming button for 3 seconds until the LED starts alternating blue and white Releasing will link the sensor with the switch in pairing mode see ...

Страница 4: ... saving during any step release button and wait until the unit double flashes blue ADDITIONAL NOTES ON OCCUPANCY TIME DELAY à By default every 60 seconds wireless sensors transmit a status message whether or not occupancy was detected during the previous period à Referred to as the sensor s heartbeat this period can be reduced to 30 seconds although this will decrease expected battery life à If a ...

Страница 5: ...he number of times equal to the current setting e g 3 times for Automatic On Occupancy Mode Following a short pause this blink back sequence will repeat 3x before exiting Interrupt blink back by pressing the button the number of times equal to the new desired setting e g 2 Vacancy Mode The LED will blink back white the new setting number as confirmation 6 To Save and Exit programming mode press an...

Страница 6: ...ton 7 times wait 2 seconds then press the button 3 times to disable location functionality or 2 times to enable 3 To Execute the command and Exit programming mode press and holding the button until the LED changes to blue then release The LED will then blink white twice as confirmation of success Note To Exit without saving during any step release button and wait until the unit double flashes blue...

Страница 7: ...s equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that ...

Отзывы: