background image

REMOTE CONTROL

00
05-50

00
05-50

05-50

50

50

00
05-50

5

5.0 m

5.0 m

0.5 m - 5.0 m

1   
2   
3   
4
5
6
7
8
9  

C1

C2

C3

C4

C1

C4

0     5 cm
1   10 cm
2   15 cm
3   20 cm
4   25 cm

No field
0.5 m - 5.0 m

*approximate values, not guaranteed

RELAY 1

RELAY 2

*approximate values, not guaranteed

Object size*

for a field height of 4 m

No field
0.5 m - 5.0 m

Field 1 = Field 2
0.5 m - 5.0 m

for a field width of 3.5 m

*only for field 2

1   Indoor 
2   Outdoor LOW
3   Outdoor MEDIUM
4   Outdoor HIGH

1   Active - NO
2   Passive - NC
3   Passive - NC
4   Active - NO

Passive - NC
Active - NO
Passive - NC
Active - NO

0   size filter deactivated
1   >   5 cm
2   > 10 cm
3   > 15 cm
4   > 20 cm

Uncovered zone

recommended in case of 
snow, dead leaves etc.

Field height

Field width

REMOTE CONTROL

Field height

Field width

ADJUSTMENTS

FIELD 1

NOT USED

FIELD 2

Immunity filter

Number of curtains*

Relay configuration

Содержание LZR-RS300

Страница 1: ...ORANGE LED LED FLASHES QUICKLY LED FLASHES NORMALLY LED FLASHES SLOWLY LED OFF DETECTION POWER ON ERROR NO DETECTION Adjustable bracket Cable conduit LED signal Visible laser beams Laser sweep recept...

Страница 2: ...x output pulse power 75W Red laser CLASS 3R wavelength 650nm max output CW power 3mW Fasten the sensor firmly to avoid vibrations If the sensor is used in environments where the temperature can descen...

Страница 3: ...r the cable if possible Drill 4 holes as indicated on the mounting template Use the adhesive mounting template to position the sensor correctly The grey area indicates the detection range Position the...

Страница 4: ...the bracket to avoid malfunctioning To unlock use a screwdriver The beams will stay activated for 15 minutes or can be turned off the same way Mounting side 1 LEFT with background 2 RIGHT with backgro...

Страница 5: ...d 0 5 m 5 0 m Field 1 Field 2 0 5 m 5 0 m for a field width of 3 5 m only for field 2 1 Indoor 2 Outdoor LOW 3 Outdoor MEDIUM 4 Outdoor HIGH 1 Active NO 2 Passive NC 3 Passive NC 4 Active NO Passive N...

Страница 6: ...arameter Set value RED RED RED OFF Power supply OFF ON How to delete an access code RED RED OFF Select code 1 4 digits How to save an access code Enter code RED OFF RED RED 1 4 digits REMOTE CONTROL H...

Страница 7: ...ial in proximity to the sensor Verify the field size Check the position of the sensor Launch a new teach in Check mounting side setting If there is no background set the mounting side to value 3 to 5...

Страница 8: ...erminal 5 W 1 8 A max 80 ms 35 V 2 m typ 20 ms max 80 ms 2 electronic relays galvanic isolated polarity free 35 V DC 24 V AC 80 mA resistive t 5 ms t 5 ms ON OFF typ 30 0 7 V 20 mA 10 A 1 blue LED pow...

Отзывы: