background image

1

2

3

4

Ex.

Do not stare into 
the laser emitter or 
the visible laser 
beams.

Do not open the 
sensor. Warranty is 
void if opened.

The sensor should 
only be installed 
and adjusted by 
authorized and 
trained staff.

After installation 
enter an access 
code to secure the 
sensor.

Caution! Use of controls, 

adjustments or performance of 

procedures other than those 

specified herein may result in 

hazardous radiation exposure.

The device contains IR and visible red laser diodes.

IR laser (CLASS 1): 

wavelength 905nm
max. output pulse power 75W

Red laser (CLASS 3R): 

wavelength 650nm
max. output CW power 3mW

Fasten the sensor 

firmly to avoid 

vibrations.

If the sensor is used in 

environments where 
the temperature can 

descend below 

0°C, keep the sensor 

permanently powered.

Avoid exposing the 

sensor to sudden and 

extreme temperature 

changes.

Smoke and fog may 

cause unwanted 

detections.

Do not cover 

the front screens.

Avoid moving objects 

in the detection field.

Avoid all types of light 

sources in the 

detection field.

Wipe the front screens  

regularly with a clean 

and damp cloth.

Do not use aggressive 
detergents or abrasive 

cleaning agents to 

clean the front screens.

Avoid condensation.

SAFETY INSTRUCTIONS

INSTALLATION TIPS

Содержание LZR-RS300

Страница 1: ...ORANGE LED LED FLASHES QUICKLY LED FLASHES NORMALLY LED FLASHES SLOWLY LED OFF DETECTION POWER ON ERROR NO DETECTION Adjustable bracket Cable conduit LED signal Visible laser beams Laser sweep recept...

Страница 2: ...x output pulse power 75W Red laser CLASS 3R wavelength 650nm max output CW power 3mW Fasten the sensor firmly to avoid vibrations If the sensor is used in environments where the temperature can descen...

Страница 3: ...r the cable if possible Drill 4 holes as indicated on the mounting template Use the adhesive mounting template to position the sensor correctly The grey area indicates the detection range Position the...

Страница 4: ...the bracket to avoid malfunctioning To unlock use a screwdriver The beams will stay activated for 15 minutes or can be turned off the same way Mounting side 1 LEFT with background 2 RIGHT with backgro...

Страница 5: ...d 0 5 m 5 0 m Field 1 Field 2 0 5 m 5 0 m for a field width of 3 5 m only for field 2 1 Indoor 2 Outdoor LOW 3 Outdoor MEDIUM 4 Outdoor HIGH 1 Active NO 2 Passive NC 3 Passive NC 4 Active NO Passive N...

Страница 6: ...arameter Set value RED RED RED OFF Power supply OFF ON How to delete an access code RED RED OFF Select code 1 4 digits How to save an access code Enter code RED OFF RED RED 1 4 digits REMOTE CONTROL H...

Страница 7: ...ial in proximity to the sensor Verify the field size Check the position of the sensor Launch a new teach in Check mounting side setting If there is no background set the mounting side to value 3 to 5...

Страница 8: ...erminal 5 W 1 8 A max 80 ms 35 V 2 m typ 20 ms max 80 ms 2 electronic relays galvanic isolated polarity free 35 V DC 24 V AC 80 mA resistive t 5 ms t 5 ms ON OFF typ 30 0 7 V 20 mA 10 A 1 blue LED pow...