Transducer Control 5 User Manual (RWT3746IM)
Revision 7, September 2020 - Page 12
User Configuration
Analog Setup
The
“Analog Setup” tab of the user configuration allows the user to configure the
transducers analog outputs.
All transducers have dual analog outputs with equal capability on both.
Analog Data Select
The Analog Data Select section allows the user to assign an internal data variable to
the output, and select a data range to be applied to the Analog Voltage Scaling.
Data Select
The following list details the available internal data variables that can be assigned
to the output. Speed and Power items are dependent on the relevant options being
fitted:
Torque
– Auto Assign
The “Torque – Auto Assign” data option will switch between Torque – Actual
and Torque
– Peak based on the state of the external peak switch input (see
the Transducer Manual for pin out and control information). If the Peak input is
switched ON, Torque
– Peak is selected, otherwise Torque – Actual is selected.
Torque
– Actual
Current torque value.
Содержание RWT440
Страница 23: ......
Страница 32: ......
Страница 33: ...Transducer Control 5 User Manual Version 5 6 Revision 7 September 2020 ...