1.1
Intended Audience
This document is written for plant maintenance personnel or those personnel who
will configure and/or collect continuous gas level and status text streams from the SEC
3500 OI, using the StatCast Feature.
Purpose
This document describes the StatCast RS232 Text Output Feature of the SEC
3500 OI, beginning with version 2.1. It will describe how to configure it, establish the
best balance of performance vs. reasonable data update rate, and what the format of the
text data broadcast stream is. This feature is very similar to the output that can be
obtained from the SEC Supervision Plus monitoring system, yet enhanced, more
configurable and more efficient for Modbus-based SEC Gas Monitor networks.
Overview
StatCast is not a new feature to the SEC product line, however it is a new addition
to the SEC 3500 Operator Interface (OI) Panel, when used with SEC 3100 Gas
Transmitters and Relay Modules.
StatCast is a broadcast server built into the SEC 3500 OI Panel Software starting
in version 2.1. It broadcasts Sensor, Zone and Global gas level and status records
continuously as formatted text over a standard RS232 Serial Port. Virtually any terminal
can capture this text, or application such as Microsoft HyperTerminal. Database
applications may desire to capture the broadcast to monitor ambient gas levels and
provide trending, as well as track alarm events.
StatCast provides Plant Floor Maintenance with the ability to configure which
data to broadcast, how fast, how many records per scan, and at what baud rate. Plant
Maintenance can decide to enable or disable the feature, and determine the appropriate
balance of data update rate vs. performance impact on the Gas monitoring loop of the
SEC 3500 with real time on-screen parameters, so that when it is finally established, there
are no hidden performance hits or unexpected or unplanned excessive data latency.
In short, the customer is in control, and in the driver’s seat. So let’s dive in and
examine more about this feature and how to use it!
Содержание SEC 3000
Страница 15: ...Doc 1460003 Rev A Operation Manual SEC 3000 Electro Chemical Gas Sensor Page 12 of 13 ...
Страница 54: ...Part Number 3100 EXP MANUAL REV 11 20141007 FIGURE 4 SEC 3100 SEC Millenium Mounting ...
Страница 55: ...Part Number 3100 EXP MANUAL REV 11 20141007 FIGURE 5 SEC 3100 SEC 3000 Mounting ...
Страница 56: ...TB 1 J1 TB 2 J2 1 6 1 6 1 4 1 6 TB 5 J5 TB 6 J6 ...
Страница 100: ...Operator Manual Page 39 of 40 P N 1580281 SEC3120 Digital Transmitter Sensor Electronics Corporation Rev 10 20150707 ...
Страница 101: ...Operator Manual Page 40 of 40 P N 1580281 SEC3120 Digital Transmitter Sensor Electronics Corporation Rev 10 20150707 ...
Страница 148: ...SEC 3120 Wiring TB 1 P3 TB 2 P6 1 6 1 6 1 2 3 4 1 2 3 4 7 6 5 4 3 2 1 TB 3 P1 TB 4 P5 ...
Страница 156: ......
Страница 158: ......
Страница 159: ......
Страница 160: ......
Страница 161: ......
Страница 399: ...SEC P N 1460014 Rev ECO A 000209 Page 11 of 26 ...
Страница 400: ...SEC P N 1460014 Rev ECO A 000209 Page 12 of 26 ...
Страница 431: ...Part Number 1460005 Revision C ...
Страница 433: ...Part Number 1460005 Revision C ...
Страница 434: ...Part Number 1460005 Revision C ...
Страница 435: ...Part Number 1460005 Revision C ...
Страница 448: ...10 VII Drawing Section Figure Title Figure 1 Wiring Diagram SEC MILLENIUM Figure 2 SEC Sensor Separation Kit ...
Страница 473: ...10 VII Drawing Section Figure Title Figure 1 Wiring Diagram SEC MILLENIUM Figure 2 SEC Sensor Separation Kit ...