Operating manual Fx9x
.
Operating mode
(DIST mm)
When in operating mode, “DIST mm“ or “DIST INCH“ appears in the first line, depending on the active unit, and
the current measured value is displayed in the second line.
When the buttons are pressed, the screen lights up.
QuickSet
The current measured value is displayed in the top line. In the centre of the bottom line, the energy value is
displayed as an alignment aid in the form of a bar graph.
Q1 and Q2 can be “taught“ directly by pressing the appropriate button
(Teach function not if SSI mode is active.)
Depending on the selected mode of signal outputs (see Teach-in menu), the rising or falling edge of the signal
output is taught with the set hysteresis in “Single switching“ mode. In “Double switching“ mode, the teach point
marks the centre of the switching points positioned 100 mm symmetrically either side (= rising or falling edge)
with the set hysteresis.
These display symbols have the following meaning:
Q1
= output 1
ON
;
q1
= output 1
OFF
Q2
= output 2
ON
;
q2
= output 2
OFF
(also indicated by yellow LEDs on the front of the device)
Quit the menu with the Enter button or ESCape function.
ESC
4564mm
Q1 ||||||| q2
Example
: QuickSet menu; current measured value 4564mm,
Q1 ON, Q2 off, receiving energy approx. 50%
Unit
( mm)
Unit makes it possible to choose between millimetres and inches as the display and output unit. The inch
display and output via the interface is in 1/10 MIL or *100 Inch (1 MIL = 1/1000 inch) , i.e. display value:
“123456“ (/100 Inch) corresponds with 1234.56 inch or 1234560 MIL.
Serial Select
(RS422 / SSI / EXT_BUS)
With
Serial Select
it is possible to select the interface from RS422, SSI1/10, SSI1/8 -compatible or EXTernal
BUSadapter. When EXT BUS is selected, “SEARCH BUS ...“ appears in the display until the connection is
established. (Bus adapters are available as accessories). Once the connection has been successfully
established, the above-mentioned text disappears. If the connection cannot be established, the text remains in
the display and the process must be cancelled with the ESCape buttons and the process can be restarted once
electrical connection has been restored.
RS422 or SSI-compatible or BUS-ADDR
(RS422 / SSI / EXT_BUS)
Depending on the setting made in
Serial Select
, the appropriate interface parameters are displayed or altered.
The following settings are possible: (delivery status = underligned)
•
RS422
Baud rate:
4.8 or 9.6 or 19.2 or 38.4 or 57.6 kBaud
Data bit:
8 or 7
Stop bit:
1 or 2
REPEAT or SINGLE: REPEAT means that the sensor continuously sends measured data via the serial
interface without waiting for a request. In SINGLE mode, a string of measured data
is only supplied on request
•
SSI:
1/10
= LSB = 0.1mm (10MIL) or
1/8
= LSB = 0.125mm (8MIL)
Different codes:
BINARY24 or BINARY25 or GRAY24 or GRAY25 are possible
•
BUS-ADDR:
Address for external
bus adapter:
Here it is possible to adjust the address for the external bus adapter, e.g.
Profibus. The address range stretches from 3 to 124. The addresses 0-2 are as
a rule reserved for the Profibus master and are therefore disabled.
The factory setting must be selected for connection with ProgSensor! (original PC Software)
SensoPart Industriesensorik GmbH, D-79695 Wieden, Tel. +49 (0)7673 821-0 Fax +49 (0)7673 821-30 www.sensopart.de
Page 7
Status 21.10.2004 Software 1.51 and higher 068-13621