Sensopart SmartRange FR 90 ILA Скачать руководство пользователя страница 4

Operating manual Fx9x 

 

.   

 

Aligning

 

FT9xILA (Measurement of distance to object) 

 

Alignment can be carried out with the aid of the integrated visible pilot laser (see chapter “Operation”).  
The fine adjustment set, available as an accessory with part no. 599-91003, can be used for finer adjustment. 
Observe the information pictured below when aligning the devices. 
 

Aussparung

Farbwechsel

Erhöhung

Ok

Ok

Drehende Welle 

Rotating shaft 

 
 

 

 

 

 

 

Dimensions of light spot

 

Fx9xILA  

 

 

 
 

27,5mm

4m

6m

10m

3mm x 10mm

4mm x 12mm

10mm x 20mm

10mm x 5mm

27,5mm

10m

200mm x 200mm

10mm x 5mm

100m

250m

50m

20mm x 20mm

100mm x 100mm

500mm x 500mm

FR 9x

FT 9x

SensoPart Industriesensorik GmbH, D-79695 Wieden, Tel. +49 (0)7673 821-0 Fax +49 (0)7673 821-30   www.sensopart.de 

Page 4 

Status 21.10.2004    Software 1.51 and higher                068-13621 

 

Содержание SmartRange FR 90 ILA

Страница 1: ...easuring device FR 91 ILA Reflector distance sensor FT 90 ILA Distance measuring device FT 91 ILA Distance sensor SensoPart Industriesensorik GmbH D 79695 Wieden Tel 49 0 7673 821 0 Fax 49 0 7673 821...

Страница 2: ...be detected or measured over long distances The FT90ILA and FT91ILA devices differ in performance data see the chapter on technical data SmartRange sensors are equipped with the following LCD display...

Страница 3: ...ight spot is in the centre of the reflector at a very short distance e g 1 m The reflector is then moved to its final position with the longest range and the position of the light spot is checked agai...

Страница 4: ...the information pictured below when aligning the devices Aussparung Farbwechsel Erh hung Ok Ok Drehende Welle Rotating shaft Dimensions of light spot Fx9xILA 27 5mm 4m 6m 10m 3mm x 10mm 4mm x 12mm 10...

Страница 5: ...tion right or increases current digit by 1 when editing In QuickSet menu it enables the teach in of Q2 In measuring mode press this button to make the display light up Left arrow button General scroll...

Страница 6: ...1 Teach1 2 HYST 1 4564mm Q1 q2 Offset 0 OFFSET nnnn OFFSET CLEAR UNIT MM UNIT MM UNIT INCH SERIAL SSI SERIAL EXT BUS SERIAL RS422 SERIAL RS422 SSI Gray25 Ext Bus Search Parameter Setup Factory OK Pass...

Страница 7: ...I EXT_BUS With Serial Select it is possible to select the interface from RS422 SSI1 10 SSI1 8 compatible or EXTernal BUSadapter When EXT BUS is selected SEARCH BUS appears in the display until the con...

Страница 8: ...nt range is valid as upper limit Analog output 0 to 20 mA only FT9x detector Mode 1 rising characteristic curve Mode 2 falling characteristic curve COPY Q A Q1 Q2 Switching point Q1 1 becomes 0 point...

Страница 9: ...hen PASSWORD active delivery status inactive Increases current digit by 1 Reduces current digit by 1 Jumps one digit further or confirms input when the far left digit has been reached and is pressed M...

Страница 10: ...EE INV ON OFF Q2 AA MODE BB LIMIT1 CC LIMIT2 DD HYST EE INV ON OFF proximity switch only Qana VALUE FF LIMIT1 CC LIMIT2 DD INV ON OFF output GG offset YYYY password dis enabled Error Status DDDDDDDD a...

Страница 11: ...g points of Q2 in mm or INCH 100 IL1 input limit Q1 1 Offset 12000 Offset or Offset 48000 Offset ACK Setting the first switching point of Q1 in mm or INCH 100 IL2 input limit Q2 1 Offset 12000 Offset...

Страница 12: ...error status can be questioned via the GSI command In principle a combination of several errors can exist e g too low a supply voltage can cause a counter error In this case the GSI command would repo...

Страница 13: ...5mm 0 1mm or 0 125mm Repeatability 2 mm 4 mm 5 mm 5 mm Linearity 10 mm 10 mm 15 mm 15 mm Response time 12 ms 12 ms 12 ms 12 ms Temperature drift 0 5 mm K 0 5 mm K Thermal response 5mm absolute 5mm abs...

Страница 14: ...ue White Signal output Q2 M GND Blue Blue 0 V GND Cable lengths shield Cable length RS422 The RS422 interface is defined as a reliable serial interface in full duplex mode with transfer rates up to 10...

Страница 15: ...12 wires 20m 12 pin connector M16 90 angle 902 51665 Connection cable 12 wires 30m 12 pin connector M16 90 angle 902 51666 Cables 12 wires Connection cable 5 wires 3m 12 pin connector M16 straight 90...

Страница 16: ...aid The aligning aid allows to see the spot of the pilot laser at large distances Using the aligning aid Mount the aligning aid on Fx9x front side Activate any menu item Pilotlaser on Look into the s...

Страница 17: ...248 218 218 6 5 4 5 RL 460 460 460 430 430 6 5 4 5 RL 660 660 660 630 630 6 5 4 5 RL 540 540 540 510 510 6 5 6 8 RL 700 700 700 670 670 6 5 6 8 SensoPart Industriesensorik GmbH D 79695 Wieden Tel 49 0...

Страница 18: ...Bit 6 Receiver blinded or faulty Bit 5 Temperature warning T 10 C or T 70 C Bit 4 No stop signal target out of range or receiver faulty Bit 3 Temperature error T 85 C Bit 2 Supply voltage too low Bit...