Sensopart SmartRange FR 90 ILA Скачать руководство пользователя страница 5

Operating manual Fx9x 

 

.   

III. Operation 

 
The

 Fx9x SmartRange 

sensors are equipped with an LCD display and 3 operating buttons which control all 

instrument functions. All parameters can be adjusted and measured values can be read via the integrated serial 
interface using PC software or your own special application programme. (Parameters of RS422 interface can only 
be altered on the device) 
 
In 

measuring mode

:  

 

the text “DIST mm“ or “DIST INCH“ (depending on unit selected)  
and the actual measured value are displayed on the screen. 

 
 
 

 
 

 

      

ESC 

DIST mm 

123456

 

 
 
 
 

The three operating buttons have the following general functions  
Button 

Name 

General operating functions 

 

Enter button 

General:  

Selects function and switches one menu level down  –  

or 

records value and switches one menu level up 

 
In operating mode: Switches to menu level   
(If password function is active, switches to password entry. Measuring mode 
remains active until correct password has been entered).  
When editing e.g. switching points: switches cursor position from right to left 
or ends entry when cursor is at the far left.  
 

 

Right arrow button  General: scrolls to the next function (right), or increases current digit by 1 

when editing.  
In “QuickSet“ menu, it enables the teach-in of Q2 
In measuring mode, press this button to make the display light up. 

 

Left arrow button 

General: scrolls to the next function (left), or reduces current digit by 1 when 
editing 
In “QuickSet“ menu, it enables the teach-in of Q1 
In measuring mode, press this button to make the display light up. 

 ESCape 

function 

Left and right 
arrow buttons 
simultaneously

Cancels active function and switches to next menu level above 
(important: buttons must be pressed simultaneously, previous value is 
maintained unaltered)  

 ESC 

 

 

Selecting menu items: 

 
Menu items are displayed in two forms:  
 
1.  

 

< Menu item>

 , with this display, it is possible to switch to another menu item with            , or select the menu 

point with       . 

 

2. 

 Menu item

 , with this display, the           keys can be used to alter the value. 

 

 
 

Note:  
The red pilot laser and the display’s background lighting are always active in set-up mode.  

 
When the sensor is switched on, the following message appears for  approx. 2 sec.: 

 
 

 

      

ESC 

Fx9x 

Rev. nnnnn

The software revision number must always be quoted when contacting the 
manufacturer with technical queries. 
 

SensoPart Industriesensorik GmbH, D-79695 Wieden, Tel. +49 (0)7673 821-0 Fax +49 (0)7673 821-30   www.sensopart.de 

Page 5 

Status 21.10.2004    Software 1.51 and higher                068-13621 

 

Содержание SmartRange FR 90 ILA

Страница 1: ...easuring device FR 91 ILA Reflector distance sensor FT 90 ILA Distance measuring device FT 91 ILA Distance sensor SensoPart Industriesensorik GmbH D 79695 Wieden Tel 49 0 7673 821 0 Fax 49 0 7673 821...

Страница 2: ...be detected or measured over long distances The FT90ILA and FT91ILA devices differ in performance data see the chapter on technical data SmartRange sensors are equipped with the following LCD display...

Страница 3: ...ight spot is in the centre of the reflector at a very short distance e g 1 m The reflector is then moved to its final position with the longest range and the position of the light spot is checked agai...

Страница 4: ...the information pictured below when aligning the devices Aussparung Farbwechsel Erh hung Ok Ok Drehende Welle Rotating shaft Dimensions of light spot Fx9xILA 27 5mm 4m 6m 10m 3mm x 10mm 4mm x 12mm 10...

Страница 5: ...tion right or increases current digit by 1 when editing In QuickSet menu it enables the teach in of Q2 In measuring mode press this button to make the display light up Left arrow button General scroll...

Страница 6: ...1 Teach1 2 HYST 1 4564mm Q1 q2 Offset 0 OFFSET nnnn OFFSET CLEAR UNIT MM UNIT MM UNIT INCH SERIAL SSI SERIAL EXT BUS SERIAL RS422 SERIAL RS422 SSI Gray25 Ext Bus Search Parameter Setup Factory OK Pass...

Страница 7: ...I EXT_BUS With Serial Select it is possible to select the interface from RS422 SSI1 10 SSI1 8 compatible or EXTernal BUSadapter When EXT BUS is selected SEARCH BUS appears in the display until the con...

Страница 8: ...nt range is valid as upper limit Analog output 0 to 20 mA only FT9x detector Mode 1 rising characteristic curve Mode 2 falling characteristic curve COPY Q A Q1 Q2 Switching point Q1 1 becomes 0 point...

Страница 9: ...hen PASSWORD active delivery status inactive Increases current digit by 1 Reduces current digit by 1 Jumps one digit further or confirms input when the far left digit has been reached and is pressed M...

Страница 10: ...EE INV ON OFF Q2 AA MODE BB LIMIT1 CC LIMIT2 DD HYST EE INV ON OFF proximity switch only Qana VALUE FF LIMIT1 CC LIMIT2 DD INV ON OFF output GG offset YYYY password dis enabled Error Status DDDDDDDD a...

Страница 11: ...g points of Q2 in mm or INCH 100 IL1 input limit Q1 1 Offset 12000 Offset or Offset 48000 Offset ACK Setting the first switching point of Q1 in mm or INCH 100 IL2 input limit Q2 1 Offset 12000 Offset...

Страница 12: ...error status can be questioned via the GSI command In principle a combination of several errors can exist e g too low a supply voltage can cause a counter error In this case the GSI command would repo...

Страница 13: ...5mm 0 1mm or 0 125mm Repeatability 2 mm 4 mm 5 mm 5 mm Linearity 10 mm 10 mm 15 mm 15 mm Response time 12 ms 12 ms 12 ms 12 ms Temperature drift 0 5 mm K 0 5 mm K Thermal response 5mm absolute 5mm abs...

Страница 14: ...ue White Signal output Q2 M GND Blue Blue 0 V GND Cable lengths shield Cable length RS422 The RS422 interface is defined as a reliable serial interface in full duplex mode with transfer rates up to 10...

Страница 15: ...12 wires 20m 12 pin connector M16 90 angle 902 51665 Connection cable 12 wires 30m 12 pin connector M16 90 angle 902 51666 Cables 12 wires Connection cable 5 wires 3m 12 pin connector M16 straight 90...

Страница 16: ...aid The aligning aid allows to see the spot of the pilot laser at large distances Using the aligning aid Mount the aligning aid on Fx9x front side Activate any menu item Pilotlaser on Look into the s...

Страница 17: ...248 218 218 6 5 4 5 RL 460 460 460 430 430 6 5 4 5 RL 660 660 660 630 630 6 5 4 5 RL 540 540 540 510 510 6 5 6 8 RL 700 700 700 670 670 6 5 6 8 SensoPart Industriesensorik GmbH D 79695 Wieden Tel 49 0...

Страница 18: ...Bit 6 Receiver blinded or faulty Bit 5 Temperature warning T 10 C or T 70 C Bit 4 No stop signal target out of range or receiver faulty Bit 3 Temperature error T 85 C Bit 2 Supply voltage too low Bit...