Housing Features

Battery Pack

The battery pack is located on the back side of the 

instrument housing.  The batteries are Lithium Ion 

rechargeable.  The batteries are only available from 

Sensit Technologies. 

To remove the battery pack turn the retaining screws 

¼ turn.  Pull the bottom of the pack away from the 

main housing.  Recharging of the battery pack requires 

removal from the main housing.

To replace slide the top tabs of the battery pack into 

the retainers at the top of the main housing.  Push the 

bottom into place and turn and lock the retaining screws.

Charge

Complete

(Green)

Charging

(Red)

Status

(Yellow)

Charger

Connection

The battery pack has LED’s to indicate charge status.  Charging should only be performed in an area 

know to be free of combustible gases.

The battery pack may also be charged while operating in a vehicle. Connect the 12vdc adapter into 

the vehicle power outlet and the external port on the battery housing. This can be connected and 

disconnected while the IRED is operating.

When the charger is disconnected, the words “WARM UP”, “PLEASE WAIT” (flashing) are displayed 

and a 180 second countdown is started/displayed. During the 180 second countdown, the user can 

not perform a measurment until the countdown expires. The instrument will only operate when on 

battery power.

Содержание IRED

Страница 1: ...instructions before use Patented SENSIT IRED INFRARED ETHANE DETECTOR 851 Transport Drive Valparaiso IN 46383 8432 MADE IN USA SENSIT Technologies is in compliance with ISO 9001 2008 Phone 888 4SENSI...

Страница 2: ...to use Always start the IRED in an area known to be gas free Tampering with this product may void the warranty Use only Sensit Technologies approved parts and accessories Never use an instrument known...

Страница 3: ...cription 4 Parts and Accessories 5 Product Specifications 6 Product Features 6 Electronic Features 7 Display Features 8 Housing Features 9 Filters 10 Field Operations 11 12 Bump Test 13 Calibration 14...

Страница 4: ...an output that is changed when certain gases absorb the light output The filter only allows specific light wavelengths to be monitored and measured The concentration of gas is proportional to the amo...

Страница 5: ...Part 873 00024 Survey Probe Filter Blue 1 Filter Part 360 00064 SENSIT IRED Calibration Kit IRED Calibration Kit Part 881 00100 Kit includes 1 Regulator 1 Cal Adapter 1 100pm Ethane Nitrogen 58L SENS...

Страница 6: ...ic Sensor Specifications IR Sensor Method Advanced Infrared Absorption Spectroscopy Detection Range 250ppb 1000ppm Warm up 30 min Calibration required 3 months Product Features The IRED is constructed...

Страница 7: ...ghting IR communication port LCD Button Operation The Sensit IRED is operated with the use of three buttons below the display They are labeled A B C The A button Activates Deactivates the instrument A...

Страница 8: ...once for manual data save GPS Connected GPS enabled not connected 8 Display Features The display provides all information including Gas concentration in PPB and PPM Battery voltage status Pump Status...

Страница 9: ...taining screws Charge Complete Green Charging Red Status Yellow Charger Connection The battery pack has LED s to indicate charge status Charging should only be performed in an area know to be free of...

Страница 10: ...r shoulder strap attachment Clips on the strap will attach securely Hydrophobic Filter Assembly WARNING Do not operate without proper filter Damage may occur to the pump and other internal parts Only...

Страница 11: ...nd Time d Warm up is indicated PLEASE WAIT with a 600 second countdown timer The countdown timer will begin after an initial warm up of 5 10 minutes e Calibration due date indicating when calibration...

Страница 12: ...imer c The measuring of ethane is indicated by the MEASUREMENT heading and the ppb ppm readings During a measurement 4 consecutive 10 second readings are taken Each reading is averaged over the 10 sec...

Страница 13: ...stable reading must occur before the process automatically continues 5 If the reading is not stable the zeroing process will automatically re initiate indicated by a RE ZEROING message This process r...

Страница 14: ...stable reading must occur before the process automatically continues 5 If the reading is not stable the zeroing process will automatically re initiate indicated by a RE ZEROING message This process r...

Страница 15: ...mplemented 10 ALARM PPM This is not implemented 11 PURGE TIME Time in Sec unit should purge system before shutting down 12 ERASE BUMP LOG Allows you to erase bump logs 13 ERASE CAL LOG Allows you to e...

Страница 16: ...Proof of purchase may be requireds before warranty is rendered Units out of warranty will be repaired for a service charge Internal repair or maintenance must be performed by a Sensit Technologies au...

Отзывы: