Gilian Gilibrator 3

®

 Dry Cell Calibrator – Operation Manual 

 

This product uses rechargeable Lithium Iron Phosphate (LiFePO

4

) batteries. 

Always 

fully charge before use

DO NOT

 

attempt to deeply discharge the internal battery 

pack.  The  internal  LiFePO

battery  pack  should  be  drained  to  25%  prior  to 

shipping. 

  

DO NOT open the Gilibrator 3 Dry Cell Calibrator, charge or replace batteries in 

an explosive atmosphere. 

Use only the charging cable provided for the Gilibrator 3 

Dry Cell Calibrator as specified in the Parts List. Battery Pack is nominal 3.2V (3.6V 

max.). 

Caution: 

Both base and battery may become warm during charging.  

 

Gilibrator 3 batteries may only be replaced by an authorized Sensidyne Service 

Center. 

LiFePO

4

 batteries must be promptly disposed of in a manner that corresponds 

to local regulatory requirements for Lithium Batteries.

 

Keep away from children.  The 

battery used in this device may present a risk of fire or chemical burn if mistreated. Do 

no  disassemble,  heat  above  140

  F  (60

⁰ 

C),  or  incinerate.  Replace  battery  with 

Sensidyne  Battery  Pack  (P/N  615-1703-011-R)  only.  Use  of  another  battery  may 

present a risk of fire or explosion. 

 

Do  not  disassemble  or  reconstruct  battery  pack. 

The  battery  pack  has  safety 

functions and a protection circuit to avoid danger. If those have serious damage, the 

pack may generate heat, smoke, rupture, or burn.  

 

Do not short-circuit battery pack. 

Do not connect the + and - terminals with metals 

(such as wire). Do not carry or store the battery pack with metal objects (such as wire, 

necklace, or hairpins). If the battery pack is short-circuited, excessive large current will 

flow and then heat generation, smoking, rupture, or burning will occur. In addition, it 

causes heat generation at metals.  

 

Do not incinerate or heat the battery pack. 

These cause the melting of insulator, 

damage of gas release vent or safety function, or ignition of electrolyte. The above 

mentioned actions cause heat generation, smoking, rupture, or burning.  

 

Do not reverse-charge or reverse-connect. 

The battery pack has polarity. In case 

the battery pack is not connected with charger or equipment smoothly, do not force 

them to connect, but do check polarity of battery pack. If the battery pack is connected 

to opposite polarity with charger, it will be reverse-charged and abnormal chemical 

reaction will occur. It causes heat generation, smoking, rupture, or burning.  

 

If the Gilibrator 3 Dry Cell Calibrator comes into contact with a destructive substance(s) 

it is the responsibility of the user to take suitable precautions that prevent the unit from 

being adversely affected. Destructive substances include acidic liquids or gases that 

may  attack metals,  solvents  that may  affect  polymeric  materials, other  solvents, or 

corrosives. Suitable precautions are regular checks as part of routine inspections and 

establishing from material data sheets that chemicals known to be present do not have 

an  adverse  effect  on  the  material  of  the  pump  (polycarbonate,  polyester,  silicone, 

Buna-N, Neoprene, Stainless steel, brass and epoxy).  

Содержание Gilian Gilibrator STABLFLOW

Страница 1: ...ual This Manual Covers All Gilibrator 3 Kit Models Sensidyne Document No 360 0213 01 Rev B 1000 112TH Circle N Suite 100 St Petersburg FL 33716 USA 800 451 9444 1 727 530 3602 www Sensidyne com info S...

Страница 2: ......

Страница 3: ...or 3 Dry Cell Calibrator Operation Manual Gilibrator 3 Identifiers A LCD Display B Status and Notification LED C Ambient Light Sensor and Charge Indicator LED D SD Card Port E Power Switch F Power Por...

Страница 4: ...d manufactured and calibrated in accordance with standards ISO 9001 2015 ISO IEC 17025 2017 ISO IEC 80079 34 ATEX Directive 2014 34 EU and IECEx where applicable Through ongoing review of our designs...

Страница 5: ...uct s operating specifications or 2 is not properly maintained in accordance with its maintenance manual or specifications or 3 has been repaired or modified by persons other than authorized Sensidyne...

Страница 6: ...brator 3 Dry Cell Calibration Kit Descriptions 8 SECTION THREE Set Up 9 3 1 System Components 9 3 2 Base Unit Components 10 3 3 Flow Cell Components 12 3 4 Preparation 13 3 5 System Set Up 14 3 6 Conn...

Страница 7: ...ed without the prior written permission of Sensidyne LP Trademark Notice Sensidyne the Sensidyne logo Gilian and Gilibrator names and logos are registered trademarks of Sensidyne LP Other trademarks a...

Страница 8: ...STORAGE OF THIS PRODUCT BY THE USER PERSON FIRM ENTITY CORPORATION OR PARTY NOT ADHERING TO THE INSTRUCTIONS AND WARNINGS IN THIS MANUAL OR OTHERWISE PROVIDED BY THE SELLER OR FROM NOT ADHERING TO ALL...

Страница 9: ...r draw liquids of any type into the unit Pump failure faulting or user injury may result Do Not operate this unit with corrosive gasses or gasses that condensate Do Not pressurize the calibrator The G...

Страница 10: ...y pack Do not connect the and terminals with metals such as wire Do not carry or store the battery pack with metal objects such as wire necklace or hairpins If the battery pack is short circuited exce...

Страница 11: ...ications Approvals and Compliances The Gilibrator 3 is EN 61010 1 CE RoHS and EMC compliant The Gilibrator 3 contains an internal battery which has been approved for shipping and transport per UN DOT...

Страница 12: ...tor 3 Dry Cell Calibration System include an easy to read color touch screen LCD display multi screen user interface with drop down menus and screen keyboard input capabilities corrections for standar...

Страница 13: ...ent accuracy determines the overall accuracy of the unit The Gilibrator 3 Dry Cell Calibration System consists of two elements the Dry Flow Cell Assembly and the Control Unit Base The function of the...

Страница 14: ...Single Cell Kit 1 Choose 1 Dry Cell 910 1702 US R Gilibrator 3 Low Flow Dry Cell 910 1703 US R Gilibrator 3 Standard Flow Dry Cell 910 1704 US R Gilibrator 3 High Flow Dry Cell Yes Two Cell Kit 1 Cho...

Страница 15: ...timing system This type of microprocessor used in conjunction with the built in software provides an extremely accurate method for calculating the flow rate parameters The Gilibrator 3 Dry Cell Calibr...

Страница 16: ...Light Sensor is located adjacent to the lower right corner of the LCD Display The LED indicates the status of battery charging The sensor allows the LCD backlight to increase to full brightness when...

Страница 17: ...cle The Inlet Fitting is located on the side of the base unit towards the top The inlet is used for makeup air when calibrating a device in suction mode The inlet fitting can also be used to connect a...

Страница 18: ...it takes the puck to travel between a pair of calibrated detectors White LED lights can be seen through the Viewing Window on Dry Cell These lights will illuminate when connected to the base and the b...

Страница 19: ...arrives assembled and has interchangeable Flow Cells that connect into the base unit Figure 3 5 IMPORTANT Before proceeding you MUST charge the battery to full capacity prior to using the calibrator T...

Страница 20: ...a complete Gilibrator 3 Dry Cell Calibration System may be configured Prior to setup make certain you have properly connected the battery charger to the power port on the backside of the Base Control...

Страница 21: ...ure device i e suction pump Tubing must be selected based on the flow range and fittings The calibration base unit comes standard with a 3 8 inch OD fitting Step down adapters are provided with the ki...

Страница 22: ...he base is powered down or when flow cells are disconnected all air paths are bridged to allow free flow of air from the inlet to the outlet and the puck is allowed to drop to the bottom of the cell O...

Страница 23: ...ell type with flow range Reports Screen Reports Screen displays most recent calibration reports by date allows for preview and export of reports and for deletion of single or all reports Settings Scre...

Страница 24: ...ecting Reference Temperature and Pressure Touch the button on the Screen adjacent to the STP icon The Input Keyboard will appear Note User may change from F to C on Settings Display Page Use keyboard...

Страница 25: ...n an averaging set Choose from one of four pre selected values or select to open a keyboard window and select a value from 3 to 20 Type the number ranging from 3 20 of samples you wish to have average...

Страница 26: ...glish Spanish French Portuguese German Dutch Italian Chinese Polish Turk Selecting Screen Brightness Touch the slider along the graduated marks to manually adjust screen brightness Furthest right is B...

Страница 27: ...me Screen and corresponding records Selecting the Ambient Pressure Units Touch the buttons adjacent the Pressure icon to select from four units of pressure in H2O mmHg kPa or hPa Note The Ambient Pres...

Страница 28: ...Description Step 1 Enter the Hour 0 23 Touch Next button Step 2 Enter the Minute 0 59 Touch Next button Step 3 Enter the Month 0 12 Touch Next button Step 4 Enter the Day 1 31 Touch Next button Step 5...

Страница 29: ...tton to initiate the test This may take up to 5 hours do not unplug or turn off the unit while test is in progress A Please Wait window will appear while the test is in progress The unit will need to...

Страница 30: ...t hose barbs Press the OK button Turn the calibrator upside down Wait for the piston inside of the flow cell to fall completely reach the top of the flow cell while upside down Return the unit to upri...

Страница 31: ...the button with the Firmware Update icon A Firmware Update instruction window will appear Press OK button to begin update Do not turn off unit until the update is complete Set Sleep Timer Touch the bu...

Страница 32: ...ned with the SmartCal format on the GilAir Plus Pump Prepare To Ship Touch the button with the Ship Gilibrator icon A Prepare to ship instruction window will appear Disconnect USB Cables Disconnect Po...

Страница 33: ...splayed in the top left corner of the Home Screen The time and date can be edited on the Settings Display page Home Screen Sampling Mode is displayed on the top right corner of the Home Screen Averagi...

Страница 34: ...ays the number of samples within an averaging set Note The sample count window does not appear in Continuous Mode Home Screen Battery Life is displayed in the bottom left corner of the Home Screen The...

Страница 35: ...he averaging sample count data set Note The Gilibrator may take several cycles to stabilize Home Screen Flow Rate displays the live flow rate measurement from the Flow Cell Reset Sample Set Touch the...

Страница 36: ...ord detail Recently Used Pump Screen This screen will populate with recently used pump information If unpopulated or the flow source name is not present touch the button labeled Skip to continue to in...

Страница 37: ...nter in the unique sample identification Touch the button labeled Next to advance to the Operator ID keyboard Pump Operator ID Keyboard Enter in the operator information Touch the button labeled Done...

Страница 38: ...sv If a post cal record is created and exported to the SD card the files will also appear in the same sub folder The post cal files will be denoted with a _ behind the sample ID ex D REPORTS Test 1 Te...

Страница 39: ...port line highlighted touch the Delete button on the display screen Delete record window appears Touch the YES button to delete the single report Preview a Report With the report line highlighted touc...

Страница 40: ...A Please Wait window will appear during data transfer Do not remove the SD card unitl transfer is complete If the file already exists on the SD Card a window will appear asking Overwrite Existing File...

Страница 41: ...rom the unit by attaching it to a null model cable and using a terminal program like PuTTY The DB9 is a standard RS232 port and sends data in the familiar Gilibrator2 format at 2400baud 8N1 A header i...

Страница 42: ...ollowing procedures to keep the unit in proper working order 1 Disconnect all cables from the Base Control Unit 2 Place black caps on both inlet and outlet fittings of Base Control Unit 3 Place black...

Страница 43: ...uck inside the flow cell due to moisture aspiration it must be returned to Sensidyne for service Direct sunlight on the unit may trigger the internal optical sensors and cause the cell to be reset or...

Страница 44: ...2018 Sensidyne LP Sensidyne Document No 360 0213 01 Rev B Page 38 Gilian Gilibrator 3 Dry Cell Calibrator Operation Manual NOTES...

Страница 45: ...S A 800 451 9444 1 727 530 3602 fax 1 727 539 0550 www Sensidyne com info Sensidyne com Authorized EU Representative Schauenburg Electronic Technologies GmbH Weseler Str 35 45478 M lheim Ruhr Germany...

Страница 46: ...1000 112th Circle N Suite 100 St Petersburg FL 33716 USA 800 451 9444 1 727 530 3602 www Sensidyne com info Sensidyne com...

Отзывы: