Figure 5 Terminals and jumpers on aSENSE

.

 The darker positions are default settings. The start point 

jumper is not mounted on some models.

 

 

WARRANTY AND LIMITATION OF LIABILITY 

 

1

. SenseAir warrants that for a period of twenty-four (24) months following receipt by 

Buyer

 

the Product

 

supplied by SenseAir to Buyer

 

will be, under normal use and care, 

free from defects in workmanship or material and to be in material conformity with 
SenseAir's specifications. Units returned to SenseAir for warranty repairs shall be 
shipped to SenseAir

at

 

Buyer’s expense, according to SenseAir's instruction. Within 

ninety (90) days of the receipt of product, SenseAir shall replace or repair such units 
and shall ship them to Buyer’s

 

designated return destination freight pre-paid. 

 

2

. Warranty Limitations. This warranty does not extend to any unit that has been 

subject to misuse, neglect or accident; that has been damaged by causes external to 
the unit; that has been used in violation of SenseAir's instructions; that has been 
affixed to any non-standard Accessory attachment; or that has been modified, 
disassembled, or reassembled by anyone other than SenseAir. 
 

3.

 The retailer is not responsible for any consequential loss or damages, which may 

occur by reason of purchase and use of this product. The warranty is, in any event, 
strictly limited to the replacement/repair of the product 
 
This product is in accordance with the 
EMC 2004/108/EC, 92/31/EEG  
including amendments by the CE-marking Directive 93/68/EEC 
The product fulfils the following demand:  
EN 61326-1:2006, Class B equipment, Table 1 - 

Basic immunity test requirements

  

 

Содержание aSENSE

Страница 1: ...well as for duct mounting The unit is designed for connecting to Direct Digital Control DDC The linear output functions are pre programmed as CO2 and temperature transmitters with jumper selected outp...

Страница 2: ...o F CO2 value mA 4 2000 16 Temperature value in o C mA 4 50 16 Temperature value in o F mA 4 16 122 32 32 a b c d Value reading a b a d c c a lowest value of the configuration b highest value of the...

Страница 3: ...erature measurements accuracy is valid only for units configured in voltage outputs mode Table II Configuration jumpers for aSENSE Self diagnostics The system contains complete self diagnostic procedu...

Страница 4: ...of Range Error Accompanies most of other errors Resets automatically after source of error disappearance Try sensor in fresh air Check connections of temperature and relative humidity probe Check deta...

Страница 5: ...e cable is to be connected to the UART port slide connector see Fig 5 For change of control parameters and re calibration CO2 and temperature this PC tool has to be used The check can be done on site...

Страница 6: ...n must be taken in order not to damage the temperature probe in the sampling tube When putting the PCB back in the protective housing the probe must be gently positioned in the sampling tube Figure 3...

Страница 7: ...hall ship them to Buyer s designated return destination freight pre paid 2 Warranty Limitations This warranty does not extend to any unit that has been subject to misuse neglect or accident that has b...

Отзывы: