SENS MicroGenius S2/S4 Technical Manual
8
Abuse
protection
Reverse polarity
Charger self-protects without fuse clearing; indication via LED and
LCD; charger recovers automatically after removal of fault condition
Wrong voltage battery Charger-battery voltage mismatch shuts down charger after 5
minutes; indication via LED and LCD
Overvoltage shutdown Selective; shutdown only operates if charger causes the overvoltage
condition. Overvoltage caused by an external voltage source does not
shut down the charger.
Over temperature
protection
Gradual output power reduction if heatsink temperature becomes
excessive
Regulatory
compliance
North America
C-UL-US Listed: CSA 22.2, No. 107.2;
UL 1012, File E114117, category
QQIJ;
UL 1236, File E109740 for category BBGQ and File EX6409 for
categories BBHH, BBJY and QWIR; certified to UL 1236 supplements
SB (marine), SC (fire pump) and SE (emergency generator)
NFPA-70; NFPA-110 when annunciating to the genset control panel
the charger’s output voltage, current, and alarm status via J1939 or
with alarm relays
FCC: Part 15, Class A commercial use and ICES-003 (Canada).
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
Seismic: rigid and non-structure wall mount; max S
DS
of 2.5G; IBC
2000-2015; California BC 2007-2016
American Bureau of Shipping: Type Approved
California Energy Commission: Title 20 Appliance Efficiency
Regulations
European Union (CE)
EMC: 2014/30/EU
EN 61000-6-4 (Emissions – Class A)
CISPR 11 – Class A
EN 61000-6-2 (Immunity – Industrial Environments)
EN 61000-4-2 Electro Static Discharge 4 kV contact, 8 kV air
EN 61000-4-3 Radiated Immunity – at 10V/m
EN 61000-4-4 Electrical Fast Transients – 2kV AC, 1kV I/O
EN 61000-4-5 Surge Immunity – 2 kV cm, 1 kV diff
EN 61000-4-6 Conducted power line immunity – 10 V r.m.s.
EN 61000-4-8 Power frequency magnetic field testing – 30 A/m
EN 61000-4-11 Voltage dips and interruptions – per the standard
LVD: 2014/35/EU
EN 60335-1 & EN 60335-2-29
RoHS 2: 2011/65/EU
EN 50581
WEEE: 2012/19/EU
This charger is considered electrical and electronic equipment (EEE)
for non-household use and should be recycled accordingly. Do not
dispose as unsorted municipal waste. See SENS website (
www.sens-
usa.com
) for information on how to properly recycle.
Construction Housing/configuration
Aluminum with powder coated finish
S2 case size: includes three ¾ inch conduit opening
S4 case size: includes one each ¾ inch, 1 inch and 1-¼ inch conduit