The iGas Detector CO
₂
is a portable single gas detector designed to detect the presence
of carbon dioxide gas in ambient environment. When activated, iGas Detector CO
₂
continuously monitors ambient air for the presence of carbon dioxide gas and alerts the
user to potentially unsafe exposure with LED, vibrating, and audible alarms in the event
that gas concentration exceeds alarm setpoints. The settings value can be adjusted
manually or by connecting to a PC software.
•
Any unauthorized attempt to repair or modify the product, or any other cause of
damage beyond the range of the intended use, including damage by fire, lightening,
or other hazard, voids liability of the manufacturer.
•
Activate this product only if sensor, visual, detection, and audible cover are clear
from contaminants such as dirt and debris that could block the area where gas is to
be detected.
•
Do not clean and rub the LCD screen of the products with a dry cloth or hands in
hazardous environment to prevent the static electricity.
•
Perform cleaning and maintenance of the products in fresh air that is free of
hazardous gases
•
Test the response of a sensor regularly by the gas concentration exceeding alarm set
points.
•
Test LED, audio and vibration manually.
•
If the temperature changes sharply during use of the device (e.g., indoors vs
outdoors), the value of the measured gas concentration can suddenly change.
Please use the detector after the gas concentration value has stabilized.
•
Severe vibration or shock to the device may cause a sudden reading change. Please
use detector after the value of gas concentration has stabilized. Excessive shock to
the detector can cause the device and/or sensor to malfunction.
•
Alarm value should be set based on the international standard. Therefore, alarm
values should be changed only under the responsibility and approval of the
administration of the work site where the instrument is used.
•
Use IR communications in the safety zone which is free of hazardous gases.
•
Replace the battery and sensor in clean environment, which is free of hazardous gas.
•
If the CO2 concentration reaches 0ppm, the calibration should be performed.
WARNING
•
Before operating this device, please read the manual carefully.
•
This device is not an analyzer, but a gas detector.
•
If calibration and self-test fails continuously, please do not use the device.
•
Clean detectors with a soft cloth and do not use chemical substances for cleaning.
CAUTION
Product Overview
Содержание iGas Detector CO2
Страница 1: ...Portable Single Gas Detector User s Manual...