background image

ENGLISH - 3/8

 

 MODULE LAYOUT 

PRELIMINARY WARNINGS

 

17.5 mm 

111 mm 

Dimensions: 

17.5 x 102.5 x 111 mm, 

Weight: 

120 g; 

Enclosure: 

PA6, black

 

The word 

WARNING

 preceded by the 

 symbol indicates conditions or actions that put the user's 

safety at risk.

 The word 

CAUTION 

preceded by the symbol

 

indicates conditions or actions that 

might damage the instrument or the connected equipment.

 

The warranty shall become null and void in the event of improper use or tampering with the device 

or any accessories supplied by the manufacturer required for its correct operation, and if the 

instructions contained in this manual are not followed.

 

WARNING: The full content of this manual must be read before operation. 

The 

module must only be used by qualified electricians.

 

Specific documentation is available from www.seneca.it/prodotti/ Z204-1

 

The module must be repaired and damaged parts replaced by the Manufacturer. The 

product is sensitive to electrostatic discharges. Take appropriate measures during any 

operation.

 

Important: Obstructing ventilation slots with any object is prohibited. 

Installing the module next to devices that generate heat is prohibited.

 

Electrical and electronic waste disposal (applicable in the European Union and other 

countries with recycling). The symbol on the product or its packaging shows that the 

product must be disposed of at a collection centre authorised to recycle electrical and 

electronic waste.

 

 ASSEMBLY STANDARDS 

The module has been designed for vertical installation on an IEC EN 60715 omega guide.       For 

optimal operation and long life, adequate ventilation must be provided. Avoid positioning channels or 

other objects that obstruct the ventilation slots. Avoid mounting modules over equipment generating 

heat. Installation in the bottom part of the switchboard is recommended.

 

102.

5 m
m

 

t

Содержание Z109TC2-1

Страница 1: ...ponds to the described products and technologies Stated data may be modified or supplemented for technical and or sales purposes INSTALLATION MANUAL Z109TC2 1 Galvanic separation thermocouple converte...

Страница 2: ...NECTIONS Removable 3 way screw terminals 5 mm pitch for cable up to 2 5 mm2 front microUSB POWER SUPPLY Voltage 10 40 Vdc or 19 28 Vac 50 60 Hz Power supply Class 2 Absorption 1 6 W 24 Vdc with 20 mA...

Страница 3: ...prodotti Z204 1 The module must be repaired and damaged parts replaced by the Manufacturer The product is sensitive to electrostatic discharges Take appropriate measures during any operation Important...

Страница 4: ...ous damage to the module Switch the module off before connecting inputs and outputs To meet the electromagnetic immunity requirements use shielded signal cables connect the shield to a preferential in...

Страница 5: ...ltage Applied current 1 External power supply current 2 V output mA output mA output 1 Already powered active output to be connected to passive inputs 2 Non powered passive output to be connected to a...

Страница 6: ...d by the yellow LED t SW1 SELECT THE THERMOCOUPLE TYPE POSITION INPUT POSITION INPUT 1 2 3 4 TYPE 1 2 3 4 TYPE Tc J Tc T Tc K Tc B Tc R Tc E Tc S Tc N KEY ON OFF Tc J Tc K Tc R Tc S Tc T Tc B 2 Tc E T...

Страница 7: ...generator 5 Press START for at least 3 seconds The green LED at the front of the device will flash to indicate that the value has been saved 6 Repeat 4 and 5 for the desired END value 7 Disconnect th...

Страница 8: ...Status LED meaning PWR FAIL Green On The device is powered correctly Flashing 1 flash sec Out of scale Burn Out or internal fault Flashing 2 flashes sec DIP switch setup error ACCESSORIES Code Descrip...

Отзывы: