background image

ENGLISH 8/8

Layout

5

6

7 8

1

1

1 0 mm

.

17.5 mm

100 mm

13 14 15 16

1 2 3 4

5 6 7 8

9 10 11 12

1

2

3 4

Disposal

Disposal of Electrical & Electronic Equipment (Applicable throughout the European Union and other European countries with separate
collection programs). This symbol, found on your product or on its packaging, indicates that this product should not be treated as household
waste when you wish to dispose of it. Instead, it should be handed over to an applicable collection point for the recycling of electrical and
electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences to the
environment and human health, which could otherwise be caused by inappropriate disposal of this product. The recycling of materials will
help to conserve natural resources. For more detailed information about the recycling of this product, please contact your local city office,
waste disposal service or thè retail store where you purchased this product.

Front LED indications

LED

STATUS

Description

PWR Green

On

The device is powered correctly.

FAIL Yellow

On

Fault: Low supply, faulty channel, faulty sensor, internal communication
error (

can be deactivated via software).

they

RX Red

On

It indicates data receiption on RS485 communication port.

TX Red

On

It indicates the data transmission on RS485 communication port.

Accessories

CODE

DESCRIPTION

Z-PC-DINAL1-35

DIN rail support with screw terminals and 1 slot P = 35 mm

Z-PC-DINAL2-

DIN rail support with screw terminals and 2 slots P = 17.5 mm

Z-PC-DIN1-35

DIN rail with 1 slot support for rear connector P = 35 mm

Z-PC-DIN2-17.5

DIN rail with 2 slots support for rear connector P = 17.5 mm

CU-A-MICROB

USB-A Micro USB-B 5 P cable

MI00441

-3

-E

N

Содержание Z-4RTD2

Страница 1: ... duplication and reproduction are forbidden The content of the present documentation refers to products and technologies described herein Such data can be modified and supplemented for technical and orcommercialreasons SENECA s r l Via Austria 26 35127 PADOVA ITALY Tel 39 049 8705355 8705359 Fax 39 049 8706287 Configuration software and manuals on our site www seneca it Technical support support s...

Страница 2: ...hms for resistance Three selectable acquisition speeds two with 13 bit resolution one with 14 bit resolution Programmable value in case of fault or freezing of last reading Compensationofthreewireresistorontheaveragevalueoftheconnectionresistor Technical Specifications Input PT100 EN 60751 A2 ITS 90 Input PT500 EN 60751 A2 ITS 90 Measuring range 200 650 C Measuring range 200 750 C Resistance range...

Страница 3: ... a s l Storage temperature 20 85 C Protection index IP20 Connections Removable 4 way screw terminals max 1 5 mm 3 5 mm pitch 2 Rear IDC10 connector for DIN rail IEC EN 60715 Micro USB on the front Overall dimensions Box Dimensions and weight W 17 5 mm H 102 5 mm D 112 mm 120g Box PA6 black Insulations Standards The instrument complies with the following standards EN61000 6 4 electromagnetic emissi...

Страница 4: ...maximum performance we recommend the use of special shielded cables such as the BELDEN 9841 Installation rules The module is designed to be installed in vertical position on a In rail DIN IEC EN 60715 order to ensure optimum performance and the longest working life the module s must be supplied with adequate ventilation and no raceways or other objects must obstruct the ventilation slots Never ins...

Страница 5: ...ances 10 m between module and probe Remember that this connection introduces a measurement error equal to the resistance of the connection cables 3 WIRES A connection to be used for medium distances 10 m between module and probe The instrument compensates the connection of the resistance cables To ensure correct compensation the cables must have the same resistance 4 WIRES A connection to be used ...

Страница 6: ...ase the noise rejection from the mains power line and to reduce measuring noise Filter IIR exponential with programmable time constant able to dampen fluctuations If an input variation is higher than threshold then both filters are forced to quickly adapt to T the new value stabilising it only later on The filter is set with the three least significant bits of registers MODBUS 40037 40 refer to se...

Страница 7: ...neca it prodotti z 4rtd2 CU A MICRO OTG CU A MICROB Connection with micro USB port for configuration via APP Connection with micro USB port for configuration via PC CU A MICROB PC Z 4RTD2 FAIL RX TX USB PWR 1314 15 16 1 2 3 4 5 6 7 8 9 10 1112 Factory Configuration Configuration of the default parameters in the module The instrument is configured at the factory with all the DIP switch in position ...

Страница 8: ...ycling of materials will help to conserve natural resources For more detailed information about the recycling of this product please contact your local city office wastedisposalserviceorthèretailstorewhereyoupurchasedthisproduct Front LED indications LED STATUS Description PWR Green On The device is powered correctly FAIL Yellow On Fault Low supply faulty channel faulty sensor internal communicati...

Отзывы: