background image

EN61000-6-4 Electromagnetic emission,
industrial environment
EN61000-6-2 Electromagnetic immunity,
industrial environment
EN61010-1 Safety

.

Linearity error

0.05%

Electromagnetics interferance

<1%

ENVIRONMENTAL CONDITION:

Operating

temperature

-20..+65°C

Storage temperature

-30..+85° C

Humidity

30..90% non-condensing

Altitude

Up to 2000 m above the sea level

CONNECTION

Terminal block

2-way removable screw terminals, 5.08 mm pitch

CASING

Size (L xW x H)

Weight

Protection index

Case material

96 x 48 x 40 mm

200 g

IP 65

Plastic

NORMS / STANDARDS

Standards

MI001943-E

ENGLISH - 3/9

Содержание S315

Страница 1: ...Page General characteristics 2 Installation instructions 4 Electrical connections 4 Parameter menu 5 Types of errors 6 Menu parameter modification 7 Parameter configuration example 8 Position of buttons and terminals 8 Programming menu diagram 9 Dimension and size 10 Disposal 10 ENGLISH 1 9 Installation manual E 4 digit display loop powered digital panel indicator ...

Страница 2: ... displayed on the 4 digit display S315 provides excellent resolution high accuracy and temperature stability The instrument is compact size Power supply from measure loop Current 4 20mA Input oop voltage drop Max 7 5 V L ADC 16bit 30V Max Measure loop powered navigation on the programming menu using the three buttons Easy on front panel the P65 wit the provided seal Protection index I h Input para...

Страница 3: ...rferance 1 ENVIRONMENTAL CONDITION Operating temperature 20 65 C Storage temperature 30 85 C Humidity 30 90 non condensing Altitude Up to 2000 m above the sea level CONNECTION Terminal block 2 way removable screw terminals 5 08 mm pitch CASING Size L xW x H Weight Protection index Case material 96 x 48 x 40 mm 200 g IP 65 Plastic NORMS STANDARDS Standards MI001943 E ENGLISH 3 9 ...

Страница 4: ...l point 1 one decimal point 2 two decimal points 0 No filter 1 5 Active Adds an offset Default settings 1 Ovenwrite the set parameter with default value and exit from menu Exit from menu By confirming with all the set OK MENU parameters will be saved on a flash memory The module is ready for use with the new setting without the need for restart Integer values between minimun and maximum Parameter Func...

Страница 5: ... lower than the set B The tha value n to be s own is ower h l MI001943 E ENGLISH 5 9 4 20mA 2 1 Electrical connections CURRENT SUPPLY AND MEASURE Installation instructions The is des gned to insta ed in the electrical switchboard n order to ensure module be i ll I optimum performance and the longest working ife the module s be supplied with l must adequate ventilation Do not install the module abo...

Страница 6: ...rameter Increases the value by o e it n un Decrease the value by one unit Confirms the value and moves the next to At the last digit press once to confirm the value and press again to return to the parameter just set Value setting notes Negative va ues l in the last field it is also possible to enter a sin or a value of 1 NOTES ANY VALUES ENTERED OUTSIDE THE RANGE ARE AUTOMATICALLY BROUGHT BACK WITHI...

Страница 7: ...99 Access DOWN MENU OK for 3 seconds until menu the menu by pressing DOWN appears is the password to lf necessary Press after entering display the next submenu Access the menu and set F 9 or a complete map of the programming menu see page Position buttons and terminals REAR REMOVABLE SCREW TERMINALS FRONTA BUTTONS L MI001943 E ENGLISH 7 9 ...

Страница 8: ...separate waste collection procedure This symbol found on your product or on its packaging indicates that this product should not be disposed of as household waste Instead it should be handed over to an authorised collection point for the recycling of electrical and electronic equipment By ensuring that this product is disposed of correctly you will help prevent potential negative consequences for ...

Страница 9: ...Programming menu diagram E Esquema del menú de programación S F Schéma du menu de programmation Premere i due tasti contemporaneamente per alcuni secondi ACCESSO AL MENÙ DI PROGRAMMAZIONE ACCESO AL MENÚ DE PROGRAMACIÓN Mantenga presionados los dos botones al mismo tiempo durante 3 segundos Push the two buttons at the same time for 3 seconds ACCESS TO THE PROGRAMMING MENU ACCÈS AU MENU DE PROGRAMMA...

Отзывы: