![Sencore DMG 3000 Скачать руководство пользователя страница 99](http://html1.mh-extra.com/html/sencore/dmg-3000/dmg-3000_user-manual_1239213099.webp)
DMG 3200/3100/3000 – User Manual
Page 99 (306)
6.1.7
Error Handling
When a situation results in an error and does not permit proper communication with the
CAM Module, an error message will be displayed. There are different conditions that can
lead to errors. Table 1 lists the possible error messages and their descriptions.
Error Message
Description
Error: No session.
Refresh to recover
communication
The user is trying to answer a menu or enquiry and the session has
been closed.
Error: Session ID.
Refresh to recover
communication.
The user is trying to access a session that is no longer available.
Error: Status. Refresh
to recover
communication.
The status count value received from GUI is not the same as the one
in the CAM Interface. This means that the GUI could be in another
level of the menu which can lead to a non desired operation.
Error: Invalid message
format.
The message parsing process is not successful.
Error: CAM No
response. Refresh to
recover
communication.
Within a specified timeout, the CAM Interface failed to respond.
No CAM/PC Card in
slot.
There is no CAM Card in the slot.
CAM not identified, or
identified as non-CAM.
The PC Card is not identified, or identified as non-CAM.
Table 2 - Error Messages and their Descriptions
When an error message is displayed, the Back/Exit button is replaced by Refresh. The
operator can either close the CAM Interface, or try to Refresh the session. If a
synchronization error occurs, Refresh is the ideal solution. Otherwise, the operator can
wait for the CAM Interface to request a Refresh automatically.
Содержание DMG 3000
Страница 36: ...DMG 3200 3100 3000 User Manual Page 36 306 Figure 4 7 IPv6 Address in Admin Page Figure 4 8 Manual IPv6 Address...
Страница 65: ...DMG 3200 3100 3000 User Manual Page 65 306 Figure 5 24 QAM Status View...
Страница 69: ...DMG 3200 3100 3000 User Manual Page 69 306 Figure 5 27 COFDM Status View...
Страница 74: ...DMG 3200 3100 3000 User Manual Page 74 306 Figure 5 29 Edit IP Port...
Страница 80: ...DMG 3200 3100 3000 User Manual Page 80 306 Figure 5 35 T2MI De Encapsulation for IP Input configuration...
Страница 119: ...DMG 3200 3100 3000 User Manual Page 119 306 Figure 6 28 Adding an EIS...
Страница 167: ...DMG 3200 3100 3000 User Manual Page 167 306 Figure 7 57 Packets dropped in Output View...
Страница 277: ...DMG 3200 3100 3000 User Manual Page 277 306 Figure 10 28 Encoder redundancy topology...
Страница 303: ...DMG 3200 3100 3000 User Manual Page 303 306 Figure 12 4 DIP switch ON DMG 3200...
Страница 306: ...Sencore Inc 3200 Sencore Drive Sioux Falls SD 57107 USA www sencore com Copyright 2014 Sencore Inc 1 605 978 4600...