DMG 3200/3100/3000 – User Manual
Page 299 (306)
When all the new modules have been inserted into the chassis, make sure that the front of the
chassis is completely closed with the front panels. Leaving a slot position open without a
module or front panel will cause the unit to draw false air and consequently result in over-
heating of the modules in the chassis.
To permanently remove modules from a specific slot position, the modules should first be
removed from the chassis. Next, go to the
About
page from the
Navigation Pane
. Click to
remove the modules. Modules flagged for removal will be crossed out. Click again to deselect
a module. Finally click
Apply Changes
to permanently remove the configuration of the module
from the chassis.
When replacing an existing module, note that a module configuration always follows the slot
position and not the module itself. Consequently, if a module is moved from one slot in the
chassis to a new slot, the unit will report the original slot position as hardware missing, while the
new slot position will be configured as a new module with default configuration. Hence if a
module is to be replaced it is important that the same slot is used.
When replacing a module with a different module type, a mismatch will occur. This will be
shown both in the alarms and in the
About
page. A DVB-S/S2 module however, can replace a
QPSK module. When this happens, a convert button will show up in the
About
page along
with the remove button. Clicking this button will enable the DVB-S/S2 module to inherit the
configuration of the old QPSK module.
It is not possible to undo this process from the web GUI.
Содержание DMG 3000
Страница 36: ...DMG 3200 3100 3000 User Manual Page 36 306 Figure 4 7 IPv6 Address in Admin Page Figure 4 8 Manual IPv6 Address...
Страница 65: ...DMG 3200 3100 3000 User Manual Page 65 306 Figure 5 24 QAM Status View...
Страница 69: ...DMG 3200 3100 3000 User Manual Page 69 306 Figure 5 27 COFDM Status View...
Страница 74: ...DMG 3200 3100 3000 User Manual Page 74 306 Figure 5 29 Edit IP Port...
Страница 80: ...DMG 3200 3100 3000 User Manual Page 80 306 Figure 5 35 T2MI De Encapsulation for IP Input configuration...
Страница 119: ...DMG 3200 3100 3000 User Manual Page 119 306 Figure 6 28 Adding an EIS...
Страница 167: ...DMG 3200 3100 3000 User Manual Page 167 306 Figure 7 57 Packets dropped in Output View...
Страница 277: ...DMG 3200 3100 3000 User Manual Page 277 306 Figure 10 28 Encoder redundancy topology...
Страница 303: ...DMG 3200 3100 3000 User Manual Page 303 306 Figure 12 4 DIP switch ON DMG 3200...
Страница 306: ...Sencore Inc 3200 Sencore Drive Sioux Falls SD 57107 USA www sencore com Copyright 2014 Sencore Inc 1 605 978 4600...