6.3.1 Scrambler Module Configuration
The scrambler module runs both the SCS functionality and the scrambler functionality on one
single card. The Scrambler supports both the DVB-CSA and AES scrambling algorithms – but
only one at a time.
The scrambler card supports up to 250 scrambled services, with a maximum total bitrate of
850Mbps.
An overview of the scramblers present in the unit is available in the
Conditional Access
node
in the
Navigation Tree
.
Figure 6.18- Scramblers Overview
This configuration page gives a general overview of how many ECMs and EMMs have been
configured as well as providing a dialog to select which scrambling algorithm to run on the card
(available algorithms depend on the licenses and SW version installed). The options provided
here are based on the information reported by the scrambler card during startup.
6.3.1.1 Configurable crypto period on the scrambler
It is possible to configure a user definable minimum crypto period (CP) per scrambler card,
under Conditional Access → Scrambling (Figure 6.18). The minimum crypto period default is
10 seconds, which is the minimum crypto period supported, but can be set as high as 6553
seconds.
If the nominal CP duration is changed as a consequence of a user changing the minimum CP,
the change takes effect the next CP. Thus, the current CP is not interrupted (neither shortened
nor lengthened in time).
6.3.1.2 Selective Scrambling/Partial Scrambling
The scrambler card supports both selective and partial scrambling, implying that parts of the
content are sent in clear. Selection is done per service and is enabled during the configuration
of the output stream. Selective scrambling is only available for selected CA systems and
requires a license.
6.3.1.3 Configuring an ECM Generator Channel
A connection to an ECM generator is defined in the
ECMG
node located under the
Conditional
Access
SCS
node in the
Navigation Tree
. The connection to an ECMG establishes a
channel over which ECMs will be sent.
Содержание DMG 3000
Страница 36: ...DMG 3200 3100 3000 User Manual Page 36 306 Figure 4 7 IPv6 Address in Admin Page Figure 4 8 Manual IPv6 Address...
Страница 65: ...DMG 3200 3100 3000 User Manual Page 65 306 Figure 5 24 QAM Status View...
Страница 69: ...DMG 3200 3100 3000 User Manual Page 69 306 Figure 5 27 COFDM Status View...
Страница 74: ...DMG 3200 3100 3000 User Manual Page 74 306 Figure 5 29 Edit IP Port...
Страница 80: ...DMG 3200 3100 3000 User Manual Page 80 306 Figure 5 35 T2MI De Encapsulation for IP Input configuration...
Страница 119: ...DMG 3200 3100 3000 User Manual Page 119 306 Figure 6 28 Adding an EIS...
Страница 167: ...DMG 3200 3100 3000 User Manual Page 167 306 Figure 7 57 Packets dropped in Output View...
Страница 277: ...DMG 3200 3100 3000 User Manual Page 277 306 Figure 10 28 Encoder redundancy topology...
Страница 303: ...DMG 3200 3100 3000 User Manual Page 303 306 Figure 12 4 DIP switch ON DMG 3200...
Страница 306: ...Sencore Inc 3200 Sencore Drive Sioux Falls SD 57107 USA www sencore com Copyright 2014 Sencore Inc 1 605 978 4600...