DMG 3200/3100/3000 – User Manual
Page 15 (306)
2.1.2 1RU Chassis DMG 3200
The 1RU chassis for the DMG 3200 holds of a total of 6 slot positions plus a slot for the
Switch/IP module. The Switch/IP module is inserted in the front of the chassis, while the
modules for the other 6 positions are inserted in the back of the chassis. All modules are hot-
swappable, including power supplies and the fan module in front.
The 1RU chassis is equipped with dual 400W AC or 500W DC power supplies
Figure 2.5 shows the front and rear view of the 1RU chassis including a mandatory switch
module, power supply connectors, and module slots.
DMG 3200
DATA A
DATA B
CONTROL
Slot #1
Slot #2
Slot #3
Slot #4
Slot #5
Slot #6
Figure 2.5 - 1RU chassis for DMG 3200 with dual power, switch module and available slots;
front and rear view.
This chassis can hold 2 power supply modules for redundancy purpose
2.1.2.1 Ventilation
This DMG 3200 has forced air flow from front to back allowing for multiple units to be stacked
above each other with no space in between. However, adequate space must be provided in
front of and behind the unit for effective ventilation.
The DMG 3200 has 6 fans in front. Fan speed is temperature controlled. If one fan fails,
remaining fans will increase speed to compensate. The whole Fan module, containing all 6
fans, can be hot swapped. If, during fan module replacement, the temperature on the inserted
modules exceeds a certain critical temperature, the unit will shut down, to prevent damage of
the inserted modules.
2.1.2.2 Replacing the power supply module
This 1RU chassis can be installed with one or two hot swappable power supply modules. The
modules can be exchanged from the rear of the unit. The chassis delivered with a single power
module can be updated by acquiring additional power module.
If power is lost in one of the Power supplies, the other can feed the entire chassis. It is
recommended to connect each input power at different circuits.
Содержание DMG 3000
Страница 36: ...DMG 3200 3100 3000 User Manual Page 36 306 Figure 4 7 IPv6 Address in Admin Page Figure 4 8 Manual IPv6 Address...
Страница 65: ...DMG 3200 3100 3000 User Manual Page 65 306 Figure 5 24 QAM Status View...
Страница 69: ...DMG 3200 3100 3000 User Manual Page 69 306 Figure 5 27 COFDM Status View...
Страница 74: ...DMG 3200 3100 3000 User Manual Page 74 306 Figure 5 29 Edit IP Port...
Страница 80: ...DMG 3200 3100 3000 User Manual Page 80 306 Figure 5 35 T2MI De Encapsulation for IP Input configuration...
Страница 119: ...DMG 3200 3100 3000 User Manual Page 119 306 Figure 6 28 Adding an EIS...
Страница 167: ...DMG 3200 3100 3000 User Manual Page 167 306 Figure 7 57 Packets dropped in Output View...
Страница 277: ...DMG 3200 3100 3000 User Manual Page 277 306 Figure 10 28 Encoder redundancy topology...
Страница 303: ...DMG 3200 3100 3000 User Manual Page 303 306 Figure 12 4 DIP switch ON DMG 3200...
Страница 306: ...Sencore Inc 3200 Sencore Drive Sioux Falls SD 57107 USA www sencore com Copyright 2014 Sencore Inc 1 605 978 4600...