background image

Page | 17 

 

Ethernet Cabling 

The exact steps for connecting to your facility via an ethernet network depends on the network requirements of your 
facility. Contact your IT Department before connecting to your facility network to ensure that there are no conflicts. 

 

DashBoard uses the open SLP protocol to locate openGear frames on the network. 

For More Information on... 

 

configuring the Network Controller card, refer to its user guide. 

 

installing and using DashBoard, refer to the 

DashBoard User Manual

 

the specifications for the AG 4800X/XS, refer to the chapter “

Technical Specifications

”. 

 

Cabling the Ethernet Port on the AG 4800X/XS Frame 

The Ethernet port is a standard 10/100/1000 RJ45 Ethernet connector and is used to exchange information with an 
external monitoring, or control, system over an ethernet network. You must have the MFC-OG3-N installed in the 
AG  4800X/XS  to  take  advantage  of  the  Gigabit  ethernet  connectivity  available  for  cards  in  the  AG  4800X/XS 
frame. 

 

Required Pinouts 

The Ethernet port has its RJ45 connector wired as a Network Interface Card (NIC). 

Table 5.1 

provides the wiring 

information based on the type of Network Controller card installed in the AG 4800X/XS frame. 

 

Table 5.1  Ethernet Port Pinouts 

 

Pin Number 

MFC-8322-S 

(10/100 Ethernet) 

MFC-OG3-N 

(10/100/1000 Ethernet) 

Signal 

Signal 

Tx+ 

TD1+ 

Tx- 

TD1- 

Rx+ 

TD2+ 

TD3+ 

TD3- 

Rx- 

TD2- 

TD4+ 

TD4- 

* Shorted, 75ohm to Ground 

 

Connecting to a Network 

Use up to 328ft (100m) of CAT6 cable or better for Gigabit Ethernet network or use up to 328ft (100m) of CAT5 
cable or better for 10/100Mbit Ethernet networks. 

To connect the Ethernet port to a network 

 

Connect the 

ETHERNET 

(RJ-45) port to the same network as your DashBoard client computer or to a network 

that has a route to the network your DashBoard client computer is on. 

1.

 

Connect one free end of a straight through CAT5/5e/6 cable to a free port of the network hub. 

2.

 

Connect the other end of the same cable to the Ethernet port on the AG 4800X/XS rear panel. 

Содержание AG4800X/XS

Страница 1: ...July 2019 Form 8192A www sencore com 1 605 978 4600 Revision 1 0 AG 4800X XS High Density Modular Frame User Manual...

Страница 2: ...directly to those companies This document may also have links to third party web pages that are beyond the control of Sencore The presence of such links does not imply that Sencore endorses or recomme...

Страница 3: ...Page 3 Revision History Date Version Description Author 05 03 2019 1 0 Initial Release MA...

Страница 4: ...fying an AG 4800X XS Rear Module 13 Rear Module Types 13 Physical Installation 14 Before You Begin 14 Static Discharge 14 Ventilation and Cooling 14 Ventilation 14 Cooling Fan Module 14 Airflow Requir...

Страница 5: ...ame 24 Maintenance 27 Installing a Frame Power Supply 27 Fan Filter Maintenance 27 Cleaning the Frame Air Filter 27 Replacing the Frame Air Filter 28 Replacing the Cooling Fan Module 29 Replacing the...

Страница 6: ...g Fan Module Technical Specifications provides the specifications for the AG 4800X XS Service Information provides information on the warranty and repair policy for your AG 4800X XS Glossary provides...

Страница 7: ...et Mask and Gateway for your device Contacting Technical Support At Sencore we take pride in the quality of our products but if problems occur help is as close as the nearest telephone After sales ser...

Страница 8: ...wappable for 24 7 operation Power switch is accessible from front of the rack frame Power supplies are replaceable from the front of the frame without requiring rear frameaccess Separate power cords t...

Страница 9: ...in the AG 4800X XS frame REF 2 GFC 8322 REF 1 SLOT 1 SLOT 2 SLOT 3 12V 7 5V SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 CAN BUS SLOT 9 SLOT 10 SLOT 11 x20 SLOT 12 SLOT 13 SLOT 14 SLOT 15 SLOT 16 SLOT 17 SLOT...

Страница 10: ...iagnostic Panel organizes the messages starting with the most recent at the top of the list Refer to the user guide for your openGear card to learn more about the types of error conditions that your c...

Страница 11: ...ion GFC 8322 Overview for more information 3 Card Slots There are a total of 20 card slots in the AG 4800X XS chassis and are used to install openGear cards into the chassis Depending on the card mode...

Страница 12: ...over Ethernet PoE 4 REF Connectors Two sets of looping BNC inputs are provided to accept two independent reference signals supporting the following reference signal types Analog black Tri level sync a...

Страница 13: ...Each module occupies two slots in the frame and accommodates one card Ensure the openGear card is installed in the correct slot in the AG 4800X XS frame Up to 10 cards can be installed in a frame when...

Страница 14: ...synthetic fiber clothing is worn Always exercise proper grounding precautions when working on circuit boards and related equipment Ventilation and Cooling Your AG 4800X XS frame was specially engineer...

Страница 15: ...ambient temperature is monitored and controlled to not exceed 40 C 104 F at the frame front door airflow intake Ensure that adequate space exists in front and behind the frame and on both sides of th...

Страница 16: ...the grounding conductor in the equipment s supply cord To reduce the risk of electrical shock to operator and service personnel this ground conductor must be connected to an earthed ground Warning In...

Страница 17: ...f the Gigabit ethernet connectivity available for cards in the AG 4800X XS frame Required Pinouts The Ethernet port has its RJ45 connector wired as a Network Interface Card NIC Table 5 1 provides the...

Страница 18: ...Page 18 To Ethernet Network Figure 5 1 AG 4800X XS Frame Ethernet Cabling CAUTION RISK OF SHOCK DO NOT OPEN 100 240V 50 60Hz 450W OGX FR CAUTION RISK OF SHOCK DO NOT OPEN 100 240V 50 60Hz 600W...

Страница 19: ...Cs This provides for ease of installation and reduction in reference cabling requirements Connecting to a Reference Source If only one reference type is required for the AG 4800X XS frame connect it t...

Страница 20: ...bleshooting During normal operation the GFC 8322 must never be removed from the AG 4800X XS frame To ensure this the metal retaining latch located on the front of the GFC 8322 must be engaged pushed d...

Страница 21: ...ard client software refer to the DashBoard UserManual To launch DashBoard 1 Ensure that DashBoard is installed on a PC connected to the same network as your AG 4800X XSframe 2 Ensure that you are runn...

Страница 22: ...ame in the Tree View AG 4800X XS frames added to the Tree View are also displayed in the Advanced Tree View 6 Repeat the procedure for each AG 4800X XS frame that you wish to add to the Tree View Re n...

Страница 23: ...devices If communication with a frame is disconnected via the Disconnect option the status indicator is light gray until the frame is re connected If the status indicator is dark gray with the rest o...

Страница 24: ...disconnect from an auto discovered frame by toggling the Automatic Discovery optionoff Using DashBoard to Access openGear Cards in the AG 4800X XS Frame The AG 4800X XS frame displays in DashBoard as...

Страница 25: ...Page 25 3 Double click an openGear card node to displays its interface in DashBoard In the example below the AG4400 was selected...

Страница 26: ...enGear card has multiple interfaces a Expand the openGear card node b Double click a sub node to display that interface in the DashBoard window In the example below the Configuration interface for an...

Страница 27: ...e rear of the frame Fan Filter Maintenance Routine maintenance of the fan filter installed in the AG 4800X XS is highly recommended to ensure proper airflow through the chassis Cleaning the Frame Air...

Страница 28: ...r sales representative before replacing the frame air filter in your AG 4800X XS frame To remove the old air filter from the frame door 1 Using a Phillips screwdriver remove the four 3 16 screws screw...

Страница 29: ...ame 1 Gently pull the side door tabs towards the center of the door releasing the door from the frame The door extender arms retain the door to the chassis 2 Using both hands pull the door towards you...

Страница 30: ...o exceed 500W Card Slots Table 9 3 Technical Specifications Card Slots Item Specifications Number of Slots 20 Total Power Available 450W Maximum Card Power High density Split Rear Modulea 15W per card...

Страница 31: ...Max Power 7 5V Rail 0 2A 1 5W Total 3 9W maximum Reference Inputs Table 9 6 Technical Specifications Reference Inputs Item Specifications Number of Inputs 2 looping Level 1Vpp nominal Signal Analog vi...

Страница 32: ...t with a unit that is known to be working correctly is an efficient method for localizing problems to individual units Sencore One Year Warranty Sencore warrants this instrument against defects from a...

Страница 33: ...r Card the MFC OG3 N and any available options unless otherwise noted NTSC captions the CEA 608 D Line 21 Data Services captions openGear frame refers to the AG 4800X XS frames unless otherwise noted...

Страница 34: ...Sencore Inc 3200 Sencore Drive Sioux Falls SD 57107 USA www sencore com 1 605 978 4600 Copyright 2019 Sencore Inc...