background image

 

10/2019

- 11 -

 Copyright © 2019, Fast ČR, a.s.

 ■

During the heating mode, water will condense from the air in the air conditioner and accumulate in the internal condensate tank. When the condensate tank is full, the display 

C6

 will show 

 (full condensate tank) and it will be necessary to remove the water from the condensate tank. Proceed according to the instructions in section “

Condensate 

drain outlet

” later in this user’s manual. Once the condensate tank is empty, the air conditioner will start running again.

Note: 

In the event that the air conditioner is located in a very cold room, to prevent potentially freezing, the air conditioner will start automatically heating the internal system. 

It may stop running temporarily. The display 

C6

 will show 

. Likewise, you may register an increased noise level. This is normal.

3. Fan  mode

 ■

Repeatedly press button 

MODE D3

 until the arrow on the display 

D1

 stops at symbol 

.

 ■

Use button 

FAN D9

 to set the fan speed. Repeatedly press button 

FAN D9 

to switch the speed in the following order: High (high speed) – Medium (medium speed) – Low (low 

speed). Each time the button is pressed, the arrow at the speed bar on the display 

D1

 will switch.

Note: 

In the fan mode, it is not possible to set the temperature, therefore no temperature information will be shown on the display 

D1

.

4. Dehumidification  mode

 ■

Repeatedly press button 

MODE D3

 until the arrow on the display 

D1

 stops at symbol  . “dH” is shown on the display 

D1

.

 ■

It is not possible to change the fan speed in the dehumidification mode.

5. Automatic  mode

 ■

If you select an automatic mode, the portable air conditioner will automatically select an operating mode based on the temperature in the room.

 ■

Repeatedly press button 

MODE D3

 until the arrow on the display 

D1

 stops at symbol 

.

 ■

Use button 

FAN D9

 to set the fan speed. Repeatedly press button 

FAN D9

 to switch the speed in the following order: High (high speed) – Medium (medium speed) – Low (low 

speed) – Auto (automatic speed). Each time the button is pressed, the arrow at the speed bar on the display 

D1

 will switch.

 ■

For models SAC MT9020C and SAC MT1220C (without the heating function) – the portable air conditioner will start in the fan mode, when the temperature in the room is less 

than 23 °C, and in the cooling mode when the temperature in the room is higher than 23 °C.

 ■

For models SAC MT1224CH and SAC MT1225CH (with the heating function) – the portable air conditioner will start in the heating mode, when the temperature in the room 

is less than 20 °C, in the fan mode if the temperature in the room is between 20 and 23 °C, and in the cooling mode when the temperature in the room is higher than 23 °C.

Functions of the portable air conditioner

1. Sleep  function

 ■

The sleep function is used to reduce overnight power consumption, when a constant temperature is not necessary.

 ■

Selecting an operating mode – heating or cooling – see previous part of the user’s manual.

 ■

Press button 

D5

, symbol 

 will appear on the display 

D1

. The portable air conditioner will run in the last selected mode. 

 ■

If the cooling mode was selected, the temperature will increase by 2 °C over a period of two hours. This new temperature will be maintained for a period of 6 hours and then the 

portable air conditioner will turn itself off.

 ■

If the heating mode was selected, the temperature will decrease by 3 °C over a period of three hours. This new temperature will be maintained for a period of 5 hours and then 

the portable air conditioner will turn itself off.

 ■

The sleep function can be cancelled at any time by pressing button 

D5

D3

 or 

D9

.

 ■

The sleep function cannot be set in the fan and dehumidification modes.

2. Automatic start and shut-off function

Automatic start

 ■

The automatic start function makes it possible to set a time after which the portable air conditioner will start automatically.

 ■

Start the portable air conditioner by pressing button 

D1

. Using button 

D3

, select the operating mode in which you wish to turn on the portable air conditioner. Use buttons 

/

 

D7

 and 

D8

 to set the desired temperature and use button 

D9

 to select a fan speed as required. Turn off the portable air conditioner using button 

D1

.

 ■

Press button 

D4

 twice, the time and symbol 

 will appear on the display 

D1

. Use buttons 

/

 

D7

 and 

D8

 to set a time after which the portable air conditioner will 

automatically start. The automatic start time can be set in the range between 30 minutes and 24 hours (set in 30 minute intervals until 10 hours, and one hour intervals until 24 hours).

 ■

Press button 

D4

 once to confirm the setting. The set time will appear on the display 

D1

 and symbol 

 will remain lit.

 ■

Once the set time elapses, the portable air conditioner will start automatically. If button 

D4

 or 

D2

 are pressed after the automatic start is set, then this setting will automatically 

be cancelled.

Automatic shut-off

 ■

The automatic shut-off function makes it possible to set a time after which the portable air conditioner will shut off automatically.

 ■

While the portable air conditioner is turned on, press button 

D4

 once. The time and symbol 

 will be shown on the display 

D1

.

 ■

Use buttons 

/

 

D7

 and 

D8

 to set a time after which the portable air conditioner will automatically turn off. The automatic shut-off time can be set in the range between 

30 minutes and 24 hours (set in 30 minute intervals until 10 hours, and one hour intervals until 24 hours).

 ■

Press button 

D4

 once to confirm the setting. The set time will appear on the display 

D1

 and symbol 

 will remain lit.

 ■

Once the set time elapses, the portable air conditioner will shut off automatically. If button 

D4

 or 

D2

 are pressed after the automatic shut-off is set, then this setting will 

automatically be cancelled.

3. Flap angle setting function

 ■

Button 

D7

 can be used to select either left or right air flow. Press button 

D7

 once, an arrow and symbol 

 will appear on the display 

D1

. Pressing button 

D7

 will cause the arrow 

to disappear and the function to be cancelled.

Changing temperature units

 ■

While the air conditioner is in stand-by mode, press button 

D10

 to toggle the temperature units from °C to °F and vice versa.

MAINTENANCE AND CLEANING

 ■

Before cleaning the portable air conditioner, turn it off and wait a few minutes, and then pull the power cord out of the power socket.

Cleaning the air filters

 ■

When the portable air conditioner is used regularly, it is necessary to clean the filters located behind the protective grille of the top and bottom air inlets 

A7

 and 

A9

 at least once 

every 14 days to prevent the fan from being clogged by dust.

 ■

Carefully remove the protective grille and take out the filters. To remove the dust, use a vacuum cleaner. In the event of greater soiling, wash the filters by hand in a solution of 

lukewarm water (max. 40 °C) and neutral detergent. Then thoroughly rinse under running water and allow to dry naturally. Do not dry it in a clothes dryer or in direct sunlight. 

Once the filters are dry, you can install them back in their place.

Note: 

Do not use the portable air conditioner without the air filters properly installed and do not use it with wet or damp air filters.

 ■

The water collection (condensation) tank must be drained immediately when the code “Ft” appears on the display 

C1

 and also before this appliance is stored in order to prevent 

the formation of moulds.

 ■

In households with pets, it is necessary to wipe the grille regularly to prevent it from becoming clogged by animal fur.

Содержание SAC MT1220C

Страница 1: ...10 2019 1 Copyright 2019 Fast R a s EN Portable Air Conditioner Translation of the original manual SAC MT9020C SAC MT9021C SAC MT1220C SAC MT1224CH SAC MT1225CH...

Страница 2: ...must not play with the appliance If the power cord is damaged it must be replaced by an authorised service centre or by another similarly qualified person this will prevent the creation of a dangerou...

Страница 3: ...r to connecting the appliance to a power socket make sure that the appliance is correctly assembled according to the instructions in this user s manual Do not touch the appliance with wet or damp hand...

Страница 4: ...fire To prevent the risk of fire or injury by electrical shock do not use this appliance with a timer or any another similar device that could spontaneously start this appliance The appliance must be...

Страница 5: ...90 Carefully study any warnings For defrosting and cleaning do not use any other tools than those recommended by the manufacturer This appliance must be located in an environment that has no continuou...

Страница 6: ...ertifies this person s competence to work with refrigerants in accordance with the specific assessment of the association for this sector Maintenance tasks must be performed solely on the basis of the...

Страница 7: ...10 2019 7 Copyright 2019 Fast R a s 1 2 3 A 8 9 7 4 5 6 10 1 B 2 3 4 5...

Страница 8: ...10 2019 8 Copyright 2019 Fast R a s 2 C 8 1 3 4 5 6 7 9 10 11 12 13 1 D 4 2 7 5 6 3 8 9 10 s E...

Страница 9: ...ource located in the room Do not locate the portable air conditioner in a room with high humidity e g laundry Note Do not use the portable air conditioner to cool a room where computer servers etc are...

Страница 10: ...rs set in 30 minute intervals until 10 hours and one hour intervals until 24 hours After a few seconds the time is saved to the memory of the air conditioner and the automatic start indicator appears...

Страница 11: ...d dehumidification modes 2 Automatic start and shut off function Automatic start The automatic start function makes it possible to set a time after which the portable air conditioner will start automa...

Страница 12: ...air filters are clean Insert a new set of batteries into the remote control Proceed according to the instructions in section Inserting and replacing batteries Install the portable air conditioner acco...

Страница 13: ...r w d h 440 369 720 mm Weight 31 kg net Operating temperature cooling 18 32 C Operating temperature heating 10 25 C Recommended room area 30 41 m2 The declared noise emission level of the appliance is...