Cleaning the outer case
■
To clean the outer case, use a soft wiping cloth dipped in a solution of lukewarm water and neutral detergent. Then wipe the surface dry.
■
When cleaning it, do not spray the portable air conditioner with water or any other liquid, do not pour water on it or submerge it in water or in any other liquid.
■
Do not use abrasive cleaning products, solvents, petrol, etc. for cleaning.
Storing the portable air conditioner
■
In order to dry it and to prevent the formation of moulds, leave the portable air conditioner running in a warm room in the fan mode for approximately 12 hours.
■
Disconnect the flexible hose
B1
and store it in a safe place out of the reach of children.
■
Drain all the condensate from the condensate tank – see chapter “
Condensate drain outlet
”.
■
Clean the air filters and reinstall them. Wipe the outer case of the portable air conditioner. Remove the batteries from the remote control.
■
Store the air conditioner in a cool, dry and dark location.
Condensate drain outlet
■
If the water level inside the condensate tank reaches a predetermined level, the portable air conditioner will show “Ft” (full condensate tank) on the display
C6
. In order to drain
the condensate from the air conditioner, proceed as follows:
1. Disconnect the power plug from the power socket.
2. Carefully re-locate the portable air conditioner to a location where the water may be drained.
3. Underneath the drain outlet
A10
, place a container into which the condensate will flow. Carefully remove the plug of the drain outlet
A10
. Connect the drain hose
B6
and
allow the condensate to flow out.
4. Once the condensate tank is empty (condensate has stopped flowing), disconnect the drain hose
B6
and put the plug back into the drain outlet
A10
.
5. Insert the power plug into a power socket and turn on the portable air conditioner.
■
If you need to ensure the condensate to be continuously drained from the portable air conditioner, it is possible to connect the drain hose
B6
to a waste water drain. Proceed as follows:
1. Disconnect the power plug from the power socket.
2. Remove the plug of the top drain outlet
A8
. Connect the drain hose
B6
. If the length of the drain hose
B6
is insufficient, then it is necessary to purchase a longer hose of the
same type. Never extend the length of the drain hose
B6
using extensions.
3. Connect the end of the drain hose
B6
to the waste water drain.
4. Insert the power plug into a power socket and turn on the portable air conditioner.
Note:
The drain hose
B6
should be installed at the same height or lower than the top drain outlet
A8
. Otherwise, the condensate will not be properly drained from the
condensate tank.
Putting into operation again
■
Check that the power cord and plug are not damaged and that the air filters are clean. Insert a new set of batteries into the remote control. Proceed according to the instructions
in section “Inserting and replacing batteries”. Install the portable air conditioner according to the instructions contained in the preceding part of this user’s manual “Installation”.
TROUBLESHOOTING
Error messages
Shown on the display Meaning
Solution
Low temperature
The portable air conditioner has a system that prevents freezing at very low temperatures.
The air conditioner will start again once the internal system is defrosted.
Defect of the heat sensor
Contact an authorised service centre.
Full condensate tank
Empty the condensate tank. Proceed according to the instructions in section "
Condensate drain outlet
" described
previously in this user's manual.
Note:
In the event that one of the aforementioned faults occurs, turn off the portable air conditioner and check for the cause of the fault. Turn it on again, and if the fault
reoccurs, turn it off, disconnect the power cord from the power socket and contact the manufacturer, an authorised service centre or a person with relevant qualifications
and have the unit repaired.
Troubleshooting
■
Before contacting an authorised service centre, please check the appliance according to the following instructions:
Problem
Possible cause
Remedy
The portable air conditioner did not turn on.
There is no current in the power socket.
Engage the circuit breaker or, alternatively, try a different power socket.
The power plug is not inserted in a power socket. Connect the power plug to the power socket.
The internal safety fuse is disengaged.
Wait 30 minutes, and if the problem persists, please contact an authorised
service centre.
The portable air conditioner runs only for
a short time.
The flexible air exhaust hose
B1
is not connected
or it is blocked.
Turn off the air conditioner, disconnect the hose, check that it is not
blocked and reconnect the hose.
Air inlets
A7
and
A9
are blocked.
Remove the obstacles preventing air supply to the inlets.
The portable air conditioner is on, but is not
cooling.
The windows and doors of the room are open.
Make sure that all doors and windows are closed.
There are heat sources inside the room.
If possible remove these heat sources.
The flexible air exhaust hose
B1
is not connected. Attach the flexible hose
B1
.
The room area is too large.
Perform a double-check of the cooled area.
An unpleasant odour is sensed while it is
running.
The air filters are clogged with dirt and dust or
animal fur.
Turn off the air conditioner and clean the filters according to the provided
instructions.
The portable air conditioner turns off approx.
3 minutes after it is turned on again.
Then compressor's safety fuse is protecting the
air conditioner against damage if turned on
sooner than after 3 minutes.
Wait several minutes and then turn the air conditioner on again.
An error message appeared on the display
C1
.
Proceed according to the instructions in section "
Error messages
".