troubleshooting
Problem/Symptom
Probable Cause
Corrective Action
Tool will not start or run slowly
No electrical power
Ensure tool is plugged in, check
power supply (fuse)
Trigger switch is defective
Replace or return to Senco autho-
rized service centre for repair
Motor is defective
Tool will not fully drive fastener
Bit is worn or incorrect bit installed Replace bit
Power capabilities of the tool have
been exceeded
Discontinue use for that applica-
tion
Tool is in reverse
Switch tool to forward
Depth of drive not set properly
See p. #8
Tool does not advance fastener
Screw length/nosepiece position is
improperly set
See p. #9
Return spring is weak or broken
Replace or return to authorized
service centre for repair
Defective collation material
Use Senco branded fasteners for
optimum performance
Defective slide body
Replace or return to authorized
service centre for repair
Screw strip is jammed in guide
track
Ensure strip slides freely in guide
track
Screws “kick out” or misdrive
during use
Screw length/nosepiece position is
improperly set
See p. #9
Incorrect bit installed
Ensure correct bit type and length
are installed
Defective or damaged feed system Return to Senco or Authorized
service centre for repair
Bit will not install
Bit not properly inserted into drive
shaft
See p. #8
Clutch teeth not aligned
Pulse trigger while holding back
release button
Not a Senco bit
Use only the appropriate Senco bit
Bit will not release
Not a Senco bit
Use only the appropriate Senco bit
Clutch teeth not aligned
Pulse trigger while holding back
release button
Bit slips off screw or screw is
driven at an angle
Tool slid forward during drive
Hold tool firmly while driving
Bit is worn or broken
Replace bit
Nosepiece is worn or damaged
Replace or return to Senco autho-
rized service centre for repair
11