![Semtic TERCAX-110 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/semtic/tercax-110/tercax-110_installation-and-service-manual_1237571028.webp)
Luxury
Air
Source
Heat
Pump
‐
Monobloc
System
27
THE
UNIT
IS
ONLY
TO
BE
USED
IN
A
CLOSED
WATER
SYSTEM.
APPLICATION
IN
AN
OPEN
WATER
CIRCUIT
CAN
LEAD
TO
EXCESSIVE
CORROSION
OF
THE
WATER
PIPING.
NEVER
USE
ZN
‐
COATED
PARTS
IN
THE
WATER
CIRCUIT.
EXCESSIVE
CORROSION
OF
THESE
PARTS
MAY
OCCUR
AS
COPPER
PIPING
IS
USED
IN
THE
INTERNAL
WATER
CIRCUIT
OF
THE
UNIT.
WHEN
USING
A
3
‐
WAY
VALVE
OR
A
2
‐
WAY
VALVE
IN
THE
WATER
CIRCUIT.
THE
RECOMMENDED
MAXIMUM
CHANGEOVER
TIME
OF
THE
VALVE
SHOULD
BE
LESS
THAN
60
SECONDS.
Charging
water
1.
Connect
the
water
supply
to
a
drain
and
fill
valve.
2.
Make
sure
the
automatic
air
purge
valve
is
open
(at
least
2
turns).
3.
Fill
with
water
until
the
water
manometer
indicates
a
pressure
of
approximately
2.0
bar.
Remove
air
in
the
circuit
as
much
as
possible
using
the
air
‐
purge
valves.
Air
present
in
the
water
circuit
might
cause
malfunctioning
of
the
optional
backup
heater.
4.
For
units
with
an
optional
backup
heater:
Check
that
the
backup
heater
vessel
is
filled
with
water
by
opening
the
pressure
relief
valve.
Water
must
flow
out
of
the
valve.
NOTE
•
During
filling,
it
might
not
be
possible
to
remove
all
the
air
in
the
system.
Remaining
air
will
be
removed
through
the
automatic
air
purge
valves
during
first
operating
hours
of
the
system.
Additional
filling
with
water
afterwards
might
be
required.
•
The
water
pressure
indicated
on
the
water
manometer
will
vary
depending
on
the
water
‐
temperature
(higher
pressure
at
higher
water
temperature).
•
However,
at
all
times
water
pressure
should
remain
above
0.3
bar
to
avoid
air
entering
the
circuit.
•
The
unit
might
dispose
some
excessive
water
through
the
pressure
relief
valve.
•
Water
quality
must
be
according
to
EN
directive
98/83
EC.
Piping
insulation
The
complete
water
circuit,
inclusive
all
piping,
must
be
insulated
to
prevent
condensation
during
cooling
operation
and
reduction
of
the
cooling
and
heating
capacity.
If
the
temperature
is
higher
than
30°C
and
the
humidity
is
higher
than
RH
80%,
then
the
thickness
of
the
sealing
materials
should
be
at
least
20
mm
in
order
to
avoid
condensation
on
the
surface
of
the
sealing.
Содержание TERCAX-110
Страница 7: ...Luxury Air Source Heat Pump Monobloc System 6 Model AXAO 11HA...
Страница 8: ...Luxury Air Source Heat Pump Monobloc System 7 Model AXAO 14HA and AXAO 16HA 3...
Страница 12: ...Luxury Air Source Heat Pump Monobloc System 11 OVERVIEW OF THE UNIT External view AXAO 06HA and AXAO 08HA...
Страница 14: ...Luxury Air Source Heat Pump Monobloc System 13 External view AXAO 11HA...
Страница 16: ...Luxury Air Source Heat Pump Monobloc System 15 External view AXAO 14HA and AXAO 16HA 3...
Страница 20: ...Luxury Air Source Heat Pump Monobloc System 19 Model AXAO 11HA Refer to the attached wiring diagram in the unit...
Страница 21: ...Luxury Air Source Heat Pump Monobloc System 20 Model AXAO 14HA Refer to the attached wiring diagram in the unit...