Semtic TERCAX-110 Скачать руководство пользователя страница 11

 

Luxury

 

Air

 

Source

 

Heat

 

Pump

Monobloc

 

System

 

10

Do

 

not

 

continue

 

to

 

run

 

the

 

unit

 

when

 

there

 

is

 

something

 

wrong

 

or

 

there

 

is

 

a

 

strange

 

smell.

   

The

 

power

 

supply

 

needs

 

to

 

be

 

shut

 

‘off’

 

to

 

stop

 

the

 

unit;

 

otherwise

 

this

 

may

 

cause

 

an

 

electrical

 

shock

 

or

 

fire.

 

 

Be

 

cautious

 

when

 

unpacking

 

and

 

installing

 

the

 

product.

   

Sharp

 

edges

 

could

 

cause

 

injury.

 

Especially

 

watch

 

the

 

edges

 

and

 

the

 

fins

 

on

 

the

 

heat

 

exchanger

 

of

 

the

 

product.

 

 

Always

 

check

 

for

 

gas

 

(refrigerant)

 

leakage

 

after

 

installation

 

or

 

repair

 

of

 

product.

   

Low

 

refrigerant

 

levels

 

may

 

cause

 

failure

 

of

 

the

 

product.

 

 

Keep

 

level

 

even

 

when

 

installing

 

the

 

product.

   

This

 

to

 

avoid

 

vibration

 

or

 

water

 

leakage.

 

 

Do

 

not

 

put

 

your

 

fingers

 

or

 

others

 

into

 

the

 

fan,

 

or

 

evaporator.

   

The

 

ventilator

 

runs

 

at

 

high

 

speed,

 

this

 

could

 

cause

 

serious

 

injury.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание TERCAX-110

Страница 1: ...SEMTIC Luft V rme Pump Source Heat Pump Monobloc system Installation and Service Manual TERCAX 110 TERCAX 160...

Страница 2: ...4HA and AXAO 16HA 3 16 CONTROL PARTS 17 Control panel 17 Wiring diagram AXAO 06HA and AXAO 08HA 18 Wiring diagram AXAO 11HA 19 Wiring diagram AXAO 14HA 20 Wiring diagram AXAO 16HA 3 21 INSTALLATION OF...

Страница 3: ...G 33 General guidelines 33 General symptoms 33 Error codes 35 TECHNICAL SPECIFICATION 36 READ THIS MANUAL CAREFULLY BEFORE STARTING UP THE UNIT DO NOT THROW IT AWAY KEEP IT IN YOUR FILES FOR FUTURE RE...

Страница 4: ...range consists out of two main versions a heating cooling version and a heating only version Both versions can optionally be delivered with an integrated backup heater for additional heating capacity...

Страница 5: ...All in One air to water heat pump Monobloc system Before starting installation please make sure that all parts are found inside the product box The Unit Box Item Image Quantity AXAO 06HA and AXAO 08H...

Страница 6: ...5 Cycle diagram As the all in one monobloc unit is an air to water heat pump there are two different fluids cycling inside the system one is refrigerant and the other is water The whole cycle diagram...

Страница 7: ...Luxury Air Source Heat Pump Monobloc System 6 Model AXAO 11HA...

Страница 8: ...Luxury Air Source Heat Pump Monobloc System 7 Model AXAO 14HA and AXAO 16HA 3...

Страница 9: ...lled the unit could fall causing injury The minimum support weight of 20g mm of the installation place is required When installing the unit in a small room please take measures like sufficient ventila...

Страница 10: ...t water could not be poured to the product directly do not allow water to run into electric parts There is a risk of fire or an electric shock IF THE PRODUCT IS NOT USED FOR A LONG TIME WE STRONGLY RE...

Страница 11: ...stalling the product Sharp edges could cause injury Especially watch the edges and the fins on the heat exchanger of the product Always check for gas refrigerant leakage after installation or repair o...

Страница 12: ...Luxury Air Source Heat Pump Monobloc System 11 OVERVIEW OF THE UNIT External view AXAO 06HA and AXAO 08HA...

Страница 13: ...ate heat exchanger 21 Three way valve 6 Fan motor holder 22 H C OUT 7 Condenser 23 DHW OUT 8 Expansion vessel 10L 24 Electronic expansion valve 9 Separated plate 25 H C IN 10 Top plate 26 DHW IN 11 Pr...

Страница 14: ...Luxury Air Source Heat Pump Monobloc System 13 External view AXAO 11HA...

Страница 15: ...grill 2 23 Water flow switch 6 Fan motor 2 24 Three way valve 7 Fan 2 25 H C OUT 8 Fan motor holder 26 DHW OUT 9 Switch box 27 Electronic expansion valve 10 Condenser 28 H C IN 11 Plate heat exchange...

Страница 16: ...Luxury Air Source Heat Pump Monobloc System 15 External view AXAO 14HA and AXAO 16HA 3...

Страница 17: ...Water flow switch 6 Fan motor 2 24 Three way valve 7 Fan 2 25 H C OUT 8 Fan motor holder 26 DHW OUT 9 Plate heat exchanger 27 Accumulator 10 Expansion vessel 10L 28 Electronic expansion valve 11 Separ...

Страница 18: ...BUTTON 3 TIMER PROGRAMMING BUTTON 12 DOMESTIC HOT WATER TEMPERATURE ADJUST BUTTON 4 HOUR ADJUST BUTTON 13 SPACE HEATING COOLING BUTTON 5 DAY OF THE WEEK ADJUST BUTTON 14 DOMESTIC WATER HEATING BUTTON...

Страница 19: ...Luxury Air Source Heat Pump Monobloc System 18 WIRING DIRGRAM Model AXAO 06HA AXAO 08HA Refer to the attached wiring diagram in the unit...

Страница 20: ...Luxury Air Source Heat Pump Monobloc System 19 Model AXAO 11HA Refer to the attached wiring diagram in the unit...

Страница 21: ...Luxury Air Source Heat Pump Monobloc System 20 Model AXAO 14HA Refer to the attached wiring diagram in the unit...

Страница 22: ...Luxury Air Source Heat Pump Monobloc System 21 Model AXAO 16HA 3 Refer to the attached wiring diagram in the unit...

Страница 23: ...ighbors of the user 3 Avoid places near a bedroom and the like so that the operation noise will cause no trouble 4 There must be sufficient space for carrying the unit into and out of the site 5 There...

Страница 24: ...acing the wall Never install the outdoor unit at a site where the suction side may be exposed directly to wind To prevent exposure to wind install a baffle plate on the air discharge side of the outdo...

Страница 25: ...E USED IN A CLOSED WATER SYSTEM APPLICATION IN AN OPEN WATER CIRCUIT CAN LEAD TO EXCESSIVE CORROSION OF THE WATER PIPING Before continuing the installation of the unit check the following points The m...

Страница 26: ...g the pre pressure of the expansion vessel check if the water volume is lower than maximum allowed water volume use graph below 7 m Actions required pre pressure must be increased calculate according...

Страница 27: ...ORM THE UNIT PIPING BY USING EXCESSIVE FORCE WHEN CONNECTING THE PIPING DEFORMATION OF THE PIPING CAN CAUSE THE UNIT TO MALFUNCTION If air moisture or dust gets in the water circuit problems may occur...

Страница 28: ...at the backup heater vessel is filled with water by opening the pressure relief valve Water must flow out of the valve NOTE During filling it might not be possible to remove all the air in the system...

Страница 29: ...field wiring must be carried out in accordance with the wiring diagram supplied with the unit and the instructions given below Be sure to use a dedicated power supply Never use a power supply shared b...

Страница 30: ...No Priority 2 Self check Fast Check Normal Mode Remarks SW3 setting This setting decides the operation mode when there is a simultaneous demand for more space heating cooling and domestic water heati...

Страница 31: ...x on loose connections or damaged electrical components 5 Fixation Check that the unit is properly fixed to avoid abnormal noises and vibrations when starting up the unit 6 Damaged equipment Check the...

Страница 32: ...The default setting is high speed III If the water flow in the system is too high e g noise of running water in the installation the speed can be lowered I or II The available external static pressur...

Страница 33: ...ves first and then contact your local dealer 4 Pressure relief valve hose Check that the pressure relief valve hose is positioned appropriately to drain the water 5 Backup heater vessel insulation cov...

Страница 34: ...your local dealer installer If the pressure relief valve is not working correctly and needs to be replaced always reconnect the flexible hose attached to the pressure relief valve to avoid water drip...

Страница 35: ...ar water is cold 0 3 bar water is hot Check that the manometer is not broken Check that the expansion vessel is not broken Check that the setting of the pre pressure of the expansion vessel is correct...

Страница 36: ...errors can be found in the table below Code Failure cause E0 HE outlet sensor failure E1 Water tank temp sensor failure E2 HE inlet sensor failure E3 Water outlet sensor failure E4 Outdoor heat exchan...

Страница 37: ...1 50 230 1 50 230 1 50 230 1 50 380 3 50 Max leaving water temperature without using backup heater C 58 Soft start kit optional Yes Yes Yes Yes No Refrigerant circuit Refrigerant Type R410A Charge Kg...

Страница 38: ...h BG1 Permitted pressure MPa 0 6 Dimensions Net HxWxD mm 1062x1138x480 1062x1138x480 1270x1204x480 1477x1198x480 1477x1198x480 Dimensions Packing HxWxD mm 1190x1205x510 1190x1205x510 1390x1271x5101600...

Отзывы: