Figure 6. Returning the drum to the vacuum fan system
Shutdown Procedure
1.
Feed the final drive and wait until the
FEED
button illuminates again before pressing the
STOP
button to
allow the drive to clear the Stage 1 chamber.
2.
Press the
STOP
button to initiate the timed shutdown. The timed shutdown is approximately five
minutes:
The Stage 1 chamber stops immediately.
The
STOP
button illuminates and the
START
button extinguishes.
Stage 2 and the vacuum fan system continue running.
3.
Wait an additional 30 seconds after the timed shutdown is completed, then press the
0
button on the
vacuum fan system control panel.
4.
When the timed shutdown is complete, push the
CONTROL POWER OFF
button on the left side of the
disintegrator to turn the unit off.
5.
Cleaning and Maintenance: Begin the daily cleaning and maintenance procedures for this unit, next
sections.