B
R E A K T A N K
H
A ND B O O K
06/2015 V4.0
5
2. Control
The Breaktank works completely automatically. Once in operation, the make-up can only be stopped
by shutting down the supply tap if necessary, or by switching off the supply voltage. Of course, the
float switch placed in the pool can also be "manually" influenced by placing it higher or lower relative
to the water level. This will shift the switching point and will eventually change the level of the bath.
The level control is equipped with a switch-on and switch-off delay so that the feed pump can never
"shuttle".
It is also important that the feed pump always runs with a back pressure of at least 1 bar. This is
necessary to let the pump run in its Q / H curve and does not suffer any damage due to overload or
cavitation. The pump pressure can be read on the mounted pressure gauge.
2.1 Display and buttons
The SEM Compact Breaktank is equipped with a digital display. The display shows all relevant
information.
Switch on the power supply:
After switching on the mains voltage, the break tank will show the software version on the display for
3 seconds. Changed settings will always be remembered after a power failure.
Normal operation:
The operating mode is shown on the display, followed by the speed of the pump in%.
StBy = Standby, break tank is standby
RUN= Pump of the break tank is in operation and replenishes the pool
RESET
LOAD
StBy
RUN
RUN
M
+
-
M
+
M
u.B. 1.3
STATUS
Содержание 2502925
Страница 2: ......
Страница 3: ...Breaktank 6 2015 art nr 2502925 EN1717 EN13077...
Страница 13: ...BREAKTANK HANDBOOK 06 2015 V4 0 10 2 4 Schematic representation of menu structure...
Страница 17: ...BREAKTANK HANDBOOK 06 2015 V4 0 14 Characteristics of the feed pump Compact break tank...
Страница 25: ...BREAKTANK HANDBOOK 06 2015 V4 0 22 Notes...