2. Control 

 

The Breaktank works completely automatically. Once in operation, the make-up can only be stopped 

by shutting down the supply tap if necessary, or by switching off the supply voltage. Of course, the 

float switch placed in the pool can also be "manually" influenced by placing it higher or lower relative 

to the water level. This will shift the switching point and will eventually change the level of the bath. 

The level control is equipped with a switch-on and switch-off delay so that the feed pump can never 

"shuttle". 

 

It is also important that the feed pump always runs with a back pressure of at least 1 bar. This is 

necessary to let the pump run in its Q / H curve and does not suffer any damage due to overload or 

cavitation. The pump pressure can be read on the mounted pressure gauge. 

 

2.1 Display and buttons 

 

The SEM Compact Breaktank is equipped with a digital display. The display shows all relevant 

information. 

 

 

 

Switch on the power supply: 

After switching on the mains voltage, the break tank will show the software version on the display for 

3 seconds. Changed settings will always be remembered after a power failure.  

 

 
 
 

 

Normal operation: 

 

The operating mode is shown on the display, followed by the speed of the pump in%. 

 

StBy = Standby, break tank is standby 

 
 

RUN= Pump of the break tank is in operation and replenishes the pool 

 
 

 

 

RESET

 

LOAD

StBy

 

RUN 

RUN         

M

+

-

M

+

M

u.B. 1.3 

STATUS

 

Содержание 2502925

Страница 1: ...fe clean swimming water SEM Waterbehandeling B V De Run 4420 5503 LR Veldhoven Netherlands Telefoon 31 0 40 257 03 40 sem semwaterbehandeling nl www semwaterbehandeling nl Handbook SEM Compact Breakta...

Страница 2: ......

Страница 3: ...Breaktank 6 2015 art nr 2502925 EN1717 EN13077...

Страница 4: ...ICE MENU 7 2 3 SETUP MENU 8 2 4 SCHEMATIC REPRESENTATION OF MENU STRUCTURE 10 3 INSTALLATION GUIDELINES 11 3 2 ELECTRICAL INSTALLATION 12 3 4 SETTING PARAMETERS 15 4 MAINTENANCE AND SERVICE 16 5 FAILU...

Страница 5: ...reaktank meets the following standards EN1717 Backflow siphoning and counter pressure are the greatest risks for the quality of drinking water The new European standard EN1717 is set up to prevent con...

Страница 6: ...ty depends on the connection size of the water pipe and the required head there may be differences between the capacities mentioned in this manual and the capacity in your situation Warranty limitatio...

Страница 7: ...andby Error Simple menu structure service and setup menu with LED display and 3 push buttons High Impact Polystyrene HIPS reservoir with a capacity of 15 liters Level measurement of the reservoir by m...

Страница 8: ...runs with a back pressure of at least 1 bar This is necessary to let the pump run in its Q H curve and does not suffer any damage due to overload or cavitation The pump pressure can be read on the mo...

Страница 9: ...n operation In the event of a fault this light will flash red green pump in operation red flashing fault the fault code on the display indicates the nature of the fault ERR1 water level in the break t...

Страница 10: ...evel The water level in the break tank is shown measured in millimeters from the bottom of the tank In this mode the setup menu is not automatically reset after 10 seconds so that the water level can...

Страница 11: ...15 Tc Switch off delay time of Level switch Input 2 The switch on the input must at least have the time parameter Tc open to close KLEP2 This parameter is only applicable if the optional solenoid valv...

Страница 12: ...ge Error 2 If the level in the tank falls below the set value set Error 2 will appear on the display Lc 0 30cm 5 C Correction factor level sensor With this factor the measured value of the level senso...

Страница 13: ...BREAKTANK HANDBOOK 06 2015 V4 0 10 2 4 Schematic representation of menu structure...

Страница 14: ...the water supply is 1 2 F The connection dimension on the discharge side of the break tank is 25 mm F Glue sleeve The rectangular overflow opening may not be closed The free outlet connection F can be...

Страница 15: ...switch If necessary the wall socket can be switched off by means of protection contacts of for example flowmeters and or thermal contacts of the swimming pool pumps etc Use signal cable of at least 2...

Страница 16: ...e level is still not 210mm 5mm please contact SEM Waterbehandeling B V After this check the break tank is ready for use If the level switch in the pool is interrogative float down contact closed then...

Страница 17: ...BREAKTANK HANDBOOK 06 2015 V4 0 14 Characteristics of the feed pump Compact break tank...

Страница 18: ...rameters The following parameters are set as standard on the PLC unit at the factory Ta 3 Tb 15 Tc 1 Td 10 Ha 14 Hb 17 Hc 22 La 13 Lb 8 Lc 5 All factory settings are suitable for normal use As wished...

Страница 19: ...run dry Make sure that the feed pump always works with a minimum back pressure of 1 bar This is to keep the pump running in its Q H curve and to prevent damage to seal and impeller The float switch is...

Страница 20: ...2 on display Suction pipe is blocked or leaking Check the suction pipe of the pump inlet blocked The discharge side of the pump is blocked by valve Release the pressure side or open the valve No readi...

Страница 21: ...ltage 24Vdc Settings and interference displays d m v LED display Control function 3 push buttons Connection extra selonoid valve s 24Vdc 8W 1 Elektrical connection Screw terminals max 1 5mm2 Dimension...

Страница 22: ...ical float has a capacity of about 800 l hour This also limits the maximum capacity of the Breaktank at 800 l h By replacing this float valve with a solenoid valve the filling capacity is increased to...

Страница 23: ...e pipe bend with M in the tank grommet 5 see photo below Use Teflon tape for this Now mount the solenoid valve 8 on the outside of the Breaktank 8 using the double nipple 7 on the tank duct 5 see phot...

Страница 24: ...lectrical installation to the professional Now connect the wiring of the solenoid valve to the terminals KLEP1 24V brown and OUT blue of the control box See also the connection diagram below The Break...

Страница 25: ...BREAKTANK HANDBOOK 06 2015 V4 0 22 Notes...

Отзывы: