background image

Pg. 5

1. Make sure that the towel radiator does not have

le

akag

e

or air lo

ck

.

2. The device shall not be positioned directly in front of an electric plug.
3. Prevent water jets from hitting the equipment.
4. Connect the temperature controller only to a suitable heating element.
5. Ensure that the mains voltage is the same as indicated in the technical specifications.
6. Make sure that the type of electric resistance is compatible with the model of towel radiator

being used (check the product specifications provided by the manufacturer). The usage of a
heating element with higher power:

- Does not increase the actual power of the towel radiator;
- Might shorten life of the heating element;
- Could damage the equipment.

7. Make sure that the power of the electric resistance does not exceed the maximum power

of the towel radiator (check the label on the heating element).

8. When installed in a room with bathtub or shower, respect the “Protection Zones” according to

IP44 insulation class (in UK according to IEE cabling directives). Furthermore, make sure to
respect all local safety directives.

9. The device has to be protected by a 30mA circuit breaker (RCD).

10. Power the device with the recommended voltage (see technical specifications).
11. If a device is directly connected to a fixed electric installation, install an isolating switch

compliant with local directives for power supply disconnection.

12. Place the "O-Ring" before the fastening area.
13. After ensuring that the "O-Ring" is correctly positioned, screw the electric resistance in the

relevant threaded hole of the towel radiator, properly secure it and insert the cover ring.

14. Extract the connecting cables from the device. The two Faston connectors and the Class I

ground connector.

15. Insert the 2 Faston into the relevant connectors of the heating element.
16. Connect the female Faston connector to Earth (only Class I).
17. Insert the lower part of the heating element into the ready connected thermostat.
18. Align the device to the towel radiator. Warning! Do not rotate the device more than 30

degrees on both directions.

19. Push the device against the base of the heating element to compress the “O-Ring”, properly

fix the related fastener so that the device remains well secured and does not rotate around
the heating element.

20. Connect the power supply cable.

DISPOSAL

This product may not be treated as ordinary household waste. It has to be disposed in proper waste
collection sites. In case of replacement it shall be returned to the distributor.
Such an end-of-life treatment of the product will preserve the environment and will reduce
consumption of natural resources.
This symbol applied to the present product indicates the obligation to bring it to a proper waste
collection site, in order to let it be disposed according to 2002/96 / CE (RAEE - WEEE) directives.

• Disconnect power supply before installation.
• Only qualified personnel can connect the electronic device to the heating element.
• Make sure that the power of the electric resistance does not exceed the maximum power allowed

by the electronic control device.

“Thesis Easy”

Electronic Control for Towel Heaters

Comfort technology division

Selmo

Selmo

Electronic

Via Pacinotti, 24 - 35030 Rubano

www.selmo.it

(PD) Italy- Tel 049.8976761, Fax 049.8976085 -

Selmo

Electronic

Via Pacinotti, 24 - 35030 Rubano

www.selmo.it

EN

Rev. 01 -  Oct. 2018

Содержание Thesis Easy

Страница 1: ...usted in order not to exceed 3 C At the end of the 2 7 hours period the device returns to previous operational mode Stand by mode THESIS EASY is a special device that controls the power output of the...

Страница 2: ...2h Timer Connector of the heating element 6 3x0 8mm Faston Neutral Class I Phase Ground Temperature sensor 10KOhm a 25 C Type NTC Compliant standards EN55014 1 EN55014 2 EN61000 3 2 EN61000 3 3 EN6033...

Страница 3: ...e of damage of the power supply cable shut down the device and do not tamper with it The damaged power supply cables can be replaced exclusively by the manufacturer or by an authorized service center...

Страница 4: ...r supply before proceeding with installation The installation has to be performed only by authorized personnel Threa d Fastening area Insulation Connector 2 Faston 6 3x0 8mm Backlit On Stand by button...

Страница 5: ...diator properly secure it and insert the cover ring 14 Extract the connecting cables from the device The two Faston connectors and the Class I ground connector 15 Insert the 2 Faston into the relevant...

Страница 6: ...cting part to the heating element is kept hidden by this special layout so that the device ts perfectly to the towel radiator Blue red backlit button The backlight indicates the status of the system T...

Страница 7: ...fter that 7 i O t returns into mode and after 22 hours the Boost mode is started again for 2 hours This sequence will repeat endlessly Timer 24h mode T24h command starts 2h Boost automatically every d...

Страница 8: ...d Boost mode active The heating element remains active for 2h For safety reasons the maximum temperature is of 3 C 7 Control Led Blinking green Boost mode active Timer 24 The heating element remains a...