Supply voltage

230VAC - 50Hz

Maximal power

2000W - 230VAC

20%

100%

÷

Operational temperature

Selectable power range

-10°C ÷ +40°C

IP degree

IP44

Insulation class

Class I, Class II

Certification mark

CE

Environment

WEEE, RoHS

Size

113x73x39mm (plastic case)

Product

Electronic control for electric towel radiators

Control type

Electronic control

Type of applications

Towel radiators

Temperature setting

Analog through rotating knob

Signaling Led /
operational modes

-Red/Blue backlit button "On/Stand-by”.
-Amber/green/red Led.
-Operational modes: Comfort, Stand-by, Boost 2h, Timer.

Connector of the heating element

6,3x0.8mm Faston

:

Neutral,

,

(Class I)

Phase Ground

Temperature sensor

10KOhm a 25°C, Type NTC

Compliant standards

EN55014-1, EN55014-2, EN61000-3-2, EN61000-3-3,
EN60335-1, EN60335-2-30, EN60335-2-43, EN50336.

Warranty

2 years

Plastic box / knobs / buttons

ABS-V0 Silver, ABS-V0 White RAL9003

Power cable

H05VVF <HAR> L=900mm; 3x1mmq - Class I; 2x1mmq - Class II;

Available electric plugs

IT-UK-Shucko-CH (Cable length =1200mm)

White

White cable RAL 9003

Available colors

Chrome

Gray cable RAL 7001

“Thesis Easy”

Electronic Control for Towel Heaters

Comfort technology division

Selmo

Selmo

Electronic

Via Pacinotti, 24 - 35030 Rubano

www.selmo.it

(PD) Italy- Tel 049.8976761, Fax 049.8976085 -

Selmo

Electronic

Via Pacinotti, 24 - 35030 Rubano

www.selmo.it

EN

Rev. 01 -  Oct. 2018

Содержание Thesis Easy

Страница 1: ...usted in order not to exceed 3 C At the end of the 2 7 hours period the device returns to previous operational mode Stand by mode THESIS EASY is a special device that controls the power output of the...

Страница 2: ...2h Timer Connector of the heating element 6 3x0 8mm Faston Neutral Class I Phase Ground Temperature sensor 10KOhm a 25 C Type NTC Compliant standards EN55014 1 EN55014 2 EN61000 3 2 EN61000 3 3 EN6033...

Страница 3: ...e of damage of the power supply cable shut down the device and do not tamper with it The damaged power supply cables can be replaced exclusively by the manufacturer or by an authorized service center...

Страница 4: ...r supply before proceeding with installation The installation has to be performed only by authorized personnel Threa d Fastening area Insulation Connector 2 Faston 6 3x0 8mm Backlit On Stand by button...

Страница 5: ...diator properly secure it and insert the cover ring 14 Extract the connecting cables from the device The two Faston connectors and the Class I ground connector 15 Insert the 2 Faston into the relevant...

Страница 6: ...cting part to the heating element is kept hidden by this special layout so that the device ts perfectly to the towel radiator Blue red backlit button The backlight indicates the status of the system T...

Страница 7: ...fter that 7 i O t returns into mode and after 22 hours the Boost mode is started again for 2 hours This sequence will repeat endlessly Timer 24h mode T24h command starts 2h Boost automatically every d...

Страница 8: ...d Boost mode active The heating element remains active for 2h For safety reasons the maximum temperature is of 3 C 7 Control Led Blinking green Boost mode active Timer 24 The heating element remains a...

Отзывы: