SmartBox® 1 / SmartBox® 2 / SmartBox® 3
8 / 16
Part no. 28 100 57 d
Pos : 47 /Anleitungen A5/Elektronik/Smartbox/1+2+3/Eingabefunktion 4- 8 @ 0
\
mod_1305114973863_817.doc x @ 12440 @ @ 1
4.Tank
volume
Adjust the tank volume with [+] [-] (100%). The default
setting is 0 L. The value must be set.
Please see a volume table for the highest value,
if available.
For a 100 m³
cyl. buried tank, this may for example
be the value 100,600 litres.
___________L
5.Tank
height
Enter inner tank height in millimetres:
e. g.: 249,0 cm (max. value = 999,9 cm)
(height without dome)
Please see a volume table for the highest value,
if available.
For a 100 m³
cyl. buried tank, this may for example
be the value 288,0 cm.
_________mm
Steps 6 + 7 are only required for SmartBox
®
2 and SmartBox
®
3
6.Relay 1
or
SmartBox 2
6.Acoustic
alarm
(Buzzer)
SmartBox 3
Switch function of relay 1 or buzzer:
Deactive
The relay does not switch in relation to
the content
Active
The relay switches in relation to the
content
ON
Forces the relay to energise (fix ON)
OFF
Forces the relay to de-energise (fix OFF)
Example of switch point setting for Active (with
hysteresis):
Enter switching points as % values from 01-99 (and/or
enter as °C value from
-99 to +99 only for probe
with
temperature measurement
)
deactive
activate with + / - to
active
press Enter to confirm
On 10%
ON: set with + / -
Enter
Off 12%
OFF: set with + / -
Enter
On +0°C
ON: set with + / -
Enter
Off +0°C
OFF: set with + / -
Enter
Deactivate
the relay or buzzer via
deactive
or input
of
0%
or
0°C
(for
On
and
Off
).
ON _______%
OFF _______%
ON _______
°
C
OFF ______
°
C
7.Relay 2
SmartBox
2+3
See
6. Relay 1
for the data for Relay 2
ON _______%
OFF_______%
ON _______
°
C
OFF ______
°
C
8.Exit
Press Enter to return to display mode
After performing entry steps 1-7, the programming process is completed. After confirmation of
step “8.Exit“, the device automatically returns to
default display mode; the current tank content
is shown in the display.
Special functions are available under entry steps 9 to 24 (see page 10).
After the end of setup, do not forget to replace the housing cover!