SmartBox® 1 / SmartBox® 2 / SmartBox® 3
14 / 16
Part no. 28 100 57 d
Pos : 63 /Anleitungen A5/STAND ARDM ODULE/Übersc hriften/Technis che Daten @ 1 \
mod_1321450820797 _817.doc x @ 21003 @ @ 1
TECHNICAL DATA
Pos : 64 /Anleitungen A5/Elektronik/Smartbox/1+2+3/Tec hnisc he Daten @ 0
\
mod_1305122552387_817.doc x @ 12575 @ @ 1
Indicator:
Supply voltage:
230 V AC 50 Hz
Degree of
protection:
IP30 or IP65 acc. to
IEC 529
Power input:
max. 2 VA
Measuring input:
4
–
20 mA; U
o
= 20 V
Resolution:
10 Bit
Relay output:
optional (see accessories)
Switching voltage:
max. 250 V AC
Analog output:
0
–
5 V DC
Switching current:
max. 3,5 A
4
–
20 mA
Dimensions
W x H x D in [mm]:
120x120x49 (IP30) or
130x130x60 (IP65)
Housing:
Polystyrene (IP30) or
Polycarbonat (IP65)
Temperature range:
Ambience
-10
°
C to +50
°
C
Probe element (relative pressure probe for level detection) / Standardprobe
Operating voltage:
20 V DC
Degree of protection:
IP 68 acc. to IEC 529
Material:
V4A; POM;
FPM; HD-PE
Length of standardprobe
(without cable):
Diameter of probe:
90 mm
22 mm
Accuracy:
± 1 %
Standard version:
250 mbar
connection cable:
6 m
Installation position:
vertically suspended, or horizontally supine
Temperature range:
Ambience Operating media:
-10
°
C to +60
°
C