background image

Available spare parts

119

Pos.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

Code

01.04.262

03.07.043

01.05.220

49.04.057

01.06.100

10.13.020

15.22.104

08.22.001

11.26.006

14.10.161

15.14.233

05.11.259

14.05.076

15.14.240

09.11.009

09.01.008

14.60.060

07.10.014

21.06.004

12.03.020

Description

Plastic front panel

Upper cover

Plastic back panel 

Supply cable

Plastic bottom 

Fixed socket 

Front panel FP104 

Cable clamp 

Varistor

Diode bridge

Input board

Auxiliary transformer

Diode

Secondary rectifier board

Switch knob

Switch

Logic+power board kit 

Fan

Belt 

Capacitor

TAB. 01

GENESIS 240 SPARE PARTS

Note:  With power electronic components order code 

16.03.102 ( thermal paste) too

7) AVAILABLE SPARE PARTS

G 240 : 

(see TAB. 01) 

:

NOTES :

Code 15.14.233 (no.11) comprises:

-  board 15.14.233 and the diode bridge 14.10.161 (no.10)

supplied loose.

The diode bridges can also be supplied separately.

Code 14.60.060 (no.17) comprises:

-  board 15.14.254 complete with power IGBT and radiator.

Neither board 15.14.254 nor the power IGBTs can be supplied

separately.

Содержание Genesis 240 TLH

Страница 1: ...REPAIRS MANUAL E N G L I S H Genesis 240 Genesis 240 TLH...

Страница 2: ...AND REPAIR INSTRUMENTS AND TOOLS 121 10 DIAGNOSIS PROCEDURE 122 LEVEL 1 LEVEL 2 11 PARTS DISMANTLING AND RE INSTALLATION PROCEDURE 152 12 OPERATING TESTS AND SETTINGS 159 13 TELEPHONE ASSISTANCE REQUE...

Страница 3: ...more sophisticated instruments tools are used By taking into account the training level of its technicians and its available instruments each service centre can decide whether to use the first or sec...

Страница 4: ...g rectifier circuit with overtemperature detection device e snubber circuit h output filter i levelling inductance with overtemperature detection device j current transducer Hall effect probe k fan l...

Страница 5: ...ormer q H F discharge generation r gas solenoid valve s cooling unit power supply circuits Some of these parts are independent while others are housed inside the following electronic cards G 240 TLH F...

Страница 6: ...e input voltage is applied to the board 15 14 233 containing the line overvoltage suppressor cir cuit b consisting of three varistor see note and the radio interference suppressor circuit b see note c...

Страница 7: ...ency emissions within limits specified by standards and to ensure G 240 s immunity against the same type of problems caused by any electronic devices connected to the same power supply source The filt...

Страница 8: ...um radiator by means of a profiled plastic bar but electrically insulated from the radiator by a strip of insulating tape with low thermal resistance The IGBT switch on control circuit is located on b...

Страница 9: ...Description of machine operation 91 n m k a o q r l c b i p j d s e f g h e FIG 6...

Страница 10: ...on air flow by a radiator temperatu re detection device this device sends a signal to the control logic which then locks the inverter and signals the fault to the front panel The diodes are connected...

Страница 11: ...Description of machine operation 93 n m k a o q r l c b i p j d s e f g h e FIG 8...

Страница 12: ...es the machine s output current to provide the following functions G 240 in MMA increase of current when welding is started hotstart the following relation applies supplied current requested current 8...

Страница 13: ...ns within the permitted limits re set occurs automatically after a few seconds in the case of the G 240 to re set the G 240 TLH press any button on the front panel All the machine electronic circuits...

Страница 14: ...ow position open circuit voltage is available on the machine terminals when it is powe red and further the hot start arc force and overheating protection functions are all enabled When the selector sw...

Страница 15: ...tart Arc Force I max external I min external I2 in Bilevel mu sec sec A A sec Hz sec sec A sec A A A min 0 0 2 0 0 6 6 0 02 20 0 02 0 0 6 0 0 0 0 6 6 6 max 25 0 200 10 0 240 240 2 00 500 2 00 10 0 240...

Страница 16: ...slope down At the end of slope down the current is maintained equal to the final current If 4th stroke Torch button released the inverter switches off and the solenoid valve is kept open for a variab...

Страница 17: ...H F discharge generation q see fig 13 The H F discharge generation circuit board 15 14 192 and the H F transformer create a series of high voltage pulses a few thousand volts to spark the TIG H F wel...

Страница 18: ...hes relay and triac via which the 230 Vac power supply voltages from the auxiliary transformer l are supplied to the pump and fan of the cooling unit WU15 during TIG operation The power supplies are r...

Страница 19: ...IG 15 5 8 auxiliary transformer l see fig 15 16 17 Provides the power supplies at the electronic board inputs It also provides the 230 Vac power supply voltages for the fans power source and cooling u...

Страница 20: ...102 Description of machine operation n m k a o q r l c b i p j d s e f g h e FIG 16 F1 F2 FIG 17...

Страница 21: ...k a o q r l c b i p j d s e f g h e FIG 18 NOTE connection of the three thermal protection probes already mentioned and the protection from the cooling unit pressure switch to the current locking circ...

Страница 22: ...LAY OUTS OF CARDS...

Страница 23: ...Lay outs of cards 105 Card 15 14 233 Fig 20...

Страница 24: ...106 Lay outs of cards Card 15 14 236 side A Fig 21...

Страница 25: ...Lay outs of cards 107 Card 15 14 236 side B Fig 22...

Страница 26: ...108 Lay outs of cards Card 15 14 236 side C Fig 23...

Страница 27: ...Lay outs of cards 109 Card 15 14 254 side A Fig 24...

Страница 28: ...110 Lay outs of cards Card 15 14 254 side B Fig 25...

Страница 29: ...Lay outs of cards 111 Card 15 14 254 side C Fig 26...

Страница 30: ...112 Lay outs of cards Card 15 14 254 side D Fig 27...

Страница 31: ...Lay outs of cards 113 Card 15 14 192 Fig 28...

Страница 32: ...114 Lay outs of cards Card 15 14 239 Fig 29...

Страница 33: ...Lay outs of cards 115 Card 15 14 240 Fig 30...

Страница 34: ...see fig n 31 The G 240 has two leds on the front panel with diagnostic functions FIG 31 Position L1 L2 Colour GREEN YELLOW Status under normal conditions ON OFF Meaning Machine powe red and master sw...

Страница 35: ...ations 117 G 240 TLH FP106 see fig 32 In addition to the two leds previously described there is also a third led with the following meaning FIG 32 Position L3 Colour RED Status under normal conditions...

Страница 36: ...led on the front panel is also off then see previous section L2 if it is off and the green led on the front panel is on then there is a fault in the adjustment circuits power supply circuits board 15...

Страница 37: ...clamp Varistor Diode bridge Input board Auxiliary transformer Diode Secondary rectifier board Switch knob Switch Logic power board kit Fan Belt Capacitor TAB 01 GENESIS 240 SPARE PARTS Note With power...

Страница 38: ...e too Pos 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Description Plastic front panel Upper cover Plastic back panel Plastic bottom Fixed socket Centralised TIG socket FP106 Plug...

Страница 39: ...board 15 14 192 Moving parts IMPORTANT Keep your hands well away from the fan when the machine is connected to the power supply Make sure that the power plug is removed and that the fan is idle befor...

Страница 40: ...station off the shelf unwelding tracce may be used instead 10 DIAGNOSIS PROCEDURE 10 1 General information The diagnosis procedure is according to this logic starting off from a known situation you a...

Страница 41: ...his batch the procedure does not apply they must be sent to SELCO for repair The board code is given on the board itself in the area indi cated in figure 34 IMPORTANT The electronic boards can undergo...

Страница 42: ...124 Diagnosis procedure Card 15 14 254 soldering side FIG 35A Card 15 14 254 soldering side FIG 35B...

Страница 43: ...h the master switch closed taking the measurement between the machine input phases and cables no 22 and no 23 In this case however if a negative result is obtained it can depend not only on the diode...

Страница 44: ...ary With the master switch open reconnect CN1 of board 15 14 233 Close the master switch and check operation of the fan presence of air flow from back to front of machine yes go on no check connection...

Страница 45: ...ate of the tracks of the 15 14 233 After removing board 15 14 192 take the following measurements values 400 V line voltage Board Connector Cables Value 15 14 233 CN3 52 50 400 Vac yes go on no after...

Страница 46: ...15 14 236 CN4 4 CN4 3 34 Vdc with torch button released CN4 4 CN4 3 0 with torch button pressed yes go on no check the torch button check continuity between CN4 4 and pin 3 Mechafin and CN4 3 and pin...

Страница 47: ...Select MMA operating mode from the front panel and apply the load 3 8 or weld selecting TIG DC LIFT 2 strokes operating mode Set 120 A via the potentiometer on the front panel Checks With the shunt on...

Страница 48: ...54 D S from IG1 to IG6 OPEN S D from IG1 to IG6 approx 0 4V With a multimeter set to Ohm check between the points of figure G S from IG3 to IG6 10 kOhm G S of IG1 and IG2 22 Ohm yes go on no replace p...

Страница 49: ...nsformer cable from each of the two output rectifier diodes Checks With a multimeter set to diode testing check between the diode terminals d e circuit open 2V e d 0 2 V yes go on no replace the diode...

Страница 50: ...TP10 TP3 5 Vdc TP13 TP3 10 Vdc yes replace board 15 14 239 or check flat cable connected to it no after disconnecting the machine from the mains power supply replace fuse F1 in 15 14 254 or in part 1...

Страница 51: ...use F1 in 15 14 254 or in part 14 60 060 Perform the same check after reconnecting connector CN3 of board 15 14 254 yes go on no after disconnecting the machine from the mains replace the front panel...

Страница 52: ...sure between the terminals CN2 2 CN2 3 0V yes go on no check continuity of connection between T1 T3 and pressure switch if WU15 present according to attached diagram on board 15 14 254 using a tester...

Страница 53: ...nd perform lift start by placing the electrode in contact with the piece and lifting the torch Checks With oscilloscope set to TRIGGER ROLL Time scale 100 ms Amplitude scale 2 V Measure on board 15 14...

Страница 54: ...ecks With oscilloscope set to TRIGGER ROLL Time scale 200 ms Amplitude scale 2 V Measure on board 15 14 254 TP14 TP3 oscillogram no 10 shows the moments before and after sparking of the arc With oscil...

Страница 55: ...on no check correct insertion of connector CN4 on board 15 14 254 with a tester set to Vdc measure between the points indicated on board 15 14 254 CN3 2 TP3 5V approx yes replace front panel FP 106 n...

Страница 56: ...yes go on no replace the front panel FP106 level 1 and 2 Stage 5 6 and 7 Do not perform these tests they apply only to G 240 Stage 8 Select the external reference from the front panel Insert the remot...

Страница 57: ...0 Vac of line yes go on no check correct insertion of the connector With multimeter set to Vdc check between the points of board 15 14 192 i ii 900 100 Vdc yes go on no replace board 15 14 192 Stage 2...

Страница 58: ...140 Diagnosis procedure J9 connector frontal side FIG 36 Card 15 14 192 FIG 37...

Страница 59: ...Diagnosis procedure 141 FIG 38 Card 15 14 233 FIG 39...

Страница 60: ...142 Diagnosis procedure Card 15 14 254 version 1 soldering side FIG 40A...

Страница 61: ...Diagnosis procedure 143 Card 15 14 254 version 2 soldering side FIG 40B soldering side view...

Страница 62: ...144 Diagnosis procedure Card 15 14 236 FP106 FIG 41...

Страница 63: ...Diagnosis procedure 145 FIG 43 H F 15 14 192 wring diagrama FIG 42...

Страница 64: ...146 Oscillograms Oscillogram 1 Oscillogram 2...

Страница 65: ...Oscillograms 147 Oscillogram 3 Oscillogram 4...

Страница 66: ...148 Oscillograms Oscillogram 5 Oscillogram 6...

Страница 67: ...Oscillograms 149 Oscillogram 7 Oscillogram 8...

Страница 68: ...150 Oscillograms Oscillogram 9 Oscillogram 10...

Страница 69: ...Oscillograms 151 Oscillogram 11...

Страница 70: ...he earth terminal on the intermediate support Unscrew the two cable grip fixing screws to release the power supply cable To refit carry out these jobs in reverse order 11 6 Cable grip Remove the power...

Страница 71: ...o not require any particular precautions 11 14 Diode bridges on board 15 14 233 The bridges can be disassembled with part 15 14 233 already removed Shear one terminal at a time inserting a pair of cut...

Страница 72: ...e solenoid valve suppor ting bracket Disconnect cables no 26 no 27 and the yellow green cable Disconnect the gas pipe To refit carry out these jobs in reverse order IMPORTANT When mounting the front n...

Страница 73: ...Parts dismantling and re installation procedure 155 FIG 44...

Страница 74: ...156 Parts dismantling and re installation procedure FIG 45...

Страница 75: ...Parts dismantling and re installation procedure 157 FIG 46 FIG 47...

Страница 76: ...158 Parts dismantling and re installation procedure FIG 48...

Страница 77: ...tments of the value can be effected with potentiometer P1 on Card 15 14 239 on the front panel 12 2 Measurement and setting of maximum current Set to 240A with the potentiometer on the front panel and...

Страница 78: ...240A via the potentiometer on the front panel and check that this is the value read by the multimeter Any value adjustments can be made via the potentiometer P2 on board 15 14 254 12 3 Measuring and c...

Страница 79: ...Operating tests and settings 161 Card 15 14 239 FIG 49...

Страница 80: ...162 Operating tests and settings Card 15 14 254 FIG 50...

Страница 81: ...Operating tests and settings 163 FP106 FIG 51...

Страница 82: ...Tecnica A T SELCO Selco technical service department Information may be given by telephone or fax calling the following numbers Tel 39 0 499413111 Fax 39 0 499413311 of via the E mail to service dept...