SEL-351R Falcon Data Sheet

Schweitzer Engineering Laboratories, Inc.

10

Figure 12

SEL-351R Falcon Lift-To-Open Enclosure 

With Door Open (wiring not shown)

Recloser Control Connections

Available in Lift-To-Open (Figure 16) and Swing-Open
(Figure 17) enclosure options.

The control cable from the recloser attaches at the
bottom of the SEL-351R Falcon enclosure to a standard
receptacle. The wiring from this receptacle continues
into the control itself, with the currents and control
landing on the side-panel terminals.

The 120 or 230 Vac power parallels voltage channel 

V1

,

as shown in the retrofit of a traditional installation in
Figure 13. If you order the SEL-351R Falcon with
additional voltage channels 

V2

V3

, and 

VS

, connect true

three-phase voltage and synchronism-check voltage to
the side-panel terminals.

An internal battery monitor/charger provides battery
charging/discharging. Through this battery
monitor/charger the SEL-351R Falcon can monitor
battery voltage. The SEL-351R Falcon puts itself to sleep
if voltage falls to a user-set threshold (or if a user-set
timer times out) after an extended outage.

The SEL-351R Falcon can also be powered with
125 Vdc or 250 Vdc.

Figure 13

Connections Inside the SEL-351R Falcon Enclosure

Control Cable

Receptacle

Batteries

NEMA Type 3R
(IP32) Enclosure

Relay
Module

Terminals

Mount 
SEL-2401 
and/or 
SEL-3022

Mount 
user-supplied 
accessory 
panel

SEL-2401 or
SEL-3622 or
SEL-2925

SEL-351R Falcon Recloser Control (not including front panel)

As many as  

7 Output 

Contacts/1 Alarm

I1, I2, I3, IN

Recloser Status

Trip and Close

SCADA
or
Other
Control

Control

Cable

120 Vac or

230 Vac Power

24 Vdc

Lead-Acid

Battery

EIA-232

EIA-232

EIA-485

As many as

6 Optoisolated

Inputs

V2

V3

VS (synchronism check)

V1 (also monitors frequency)

12 Vdc power

to SEL-2401 or 

SEL-3622 (if installed)

Power In

12 Vdc Out

Ordering
Option

Ordering

Option

Close Power

(if recloser

is equipped)

36 Vdc

Power Supply

12 Vdc

Power Supply

Battery 

Monitor/

Charger

Control

Power Supply

24 or 36 Vdc Out

+

Содержание SEL-351R Falcon

Страница 1: ...BITS communi cations speeds protection and improves security Customize controls by using enhanced SELOGIC control equations for improved system operation Configurable front panel control labels simpl...

Страница 2: ...ose interval The reset times are set separately for reset timing for an auto reclose and reset timing for a manual remote close from lockout Traditionally the reset time for a manual remote close from...

Страница 3: ...y inverse class C extremely inverse long time inverse short time inverse Programmable curves user designed Four 4 programmable curves Optional 3 Phase Voltage connect to voltage channels V1 V2 and V3...

Страница 4: ...er wear monitor measures unfiltered ac current at the time of trip and the number of close to open operations as a means of monitoring this wear Every time the recloser trips the recloser control reco...

Страница 5: ...27 IRIG B SERIAL PORT 1 1 2 3 4 5 N C 7 8 SERIAL PORT 2 SERIAL PORT 3 OUT102 OUT101 OUT104 OUT103 OUT107 N C N C IN101 ALARM IN103 IN102 N C N C IN104 _ RECLOSER CONTROL I1 Z01 I2 Z02 I3 Z03 IN Z04 12...

Страница 6: ...ttings Create Application Designs that include the most commonly used relay features and settings for your system see Figure 6 and watch commissioning times drop drastically Figure 6 Example Applicati...

Страница 7: ...ress for 3 sec AUX 1 AUX 2 WAKE UP CLOSED RECLOSER OPEN RECLOSER TRIP CLOSE C B A LOCKOUT CYCLE CURVE FAST TAG HOT LINE PROBLEM BATTERY SUPPLY AC CURRENT HIGH 81 G SEF RESET A01 A04 A03 A02 A07 A06 A0...

Страница 8: ...CLE CURVE FAST TAG HOT LINE PROBLEM BATTERY SUPPLY AC CURRENT HIGH 81 G SEF RESET A01 A04 A03 A02 A07 A06 A05 A08 A11 A10 A09 A14 A13 A12 A23 A16 A15 A17 A18 A22 A20 A19 A21 A26 A25 A24 A28 A27 IRIG B...

Страница 9: ...digital quantities having a logical value of either 0 or 1 The terms assert or asserted refer to a Relay Word bit that has a value of 1 or is changing from 0 to 1 The terms deassert or deasserted refe...

Страница 10: ...ry monitor charger the SEL 351R Falcon can monitor battery voltage The SEL 351R Falcon puts itself to sleep if voltage falls to a user set threshold or if a user set timer times out after an extended...

Страница 11: ...n change most functions by programming to meet system requirements see Table 4 Use the optional configurable labels to customize the targets and control pushbuttons to best meet operational needs r Se...

Страница 12: ...le CYCLE The control is actively in the trip reclose cycle mode LOCKOUT All reclose attempts were unsuccessful A B C a A B or C phase involved in fault G Ground involved in fault SEF Sensitive earth f...

Страница 13: ...ol via serial communications These values shall be available for use in control logic Secure Communications The recloser control shall include an optional accessory for converting an EIA 232 serial po...

Страница 14: ...tored Close Circuit Points Monitored Trip Circuit Points B D C A E F IRIG B 1 2 3 4 5 N C 7 8 FRONT PANEL OPERATOR CONTROLS 28 Vdc 24 Vdc 24 Vdc or 36 Vdc 12 Vdc FRONT PANEL TARGET LEDS AC SUPPLY CONT...

Страница 15: ...Schweitzer Engineering Laboratories Inc SEL 351R Falcon Data Sheet 15 Relay Mounting Figure 16 SEL 351R Falcon Lift To Open Enclosure Dimensions and Mounting...

Страница 16: ...SEL 351R Falcon Data Sheet Schweitzer Engineering Laboratories Inc 16 Figure 17 SEL 351R Falcon Swing Open Enclosure Dimensions and Mounting...

Страница 17: ...ages Frequency and Rotation System Frequency 50 or 60 Hz Phase Rotation ABC or ACB Frequency Tracking Range 40 1 65 Hz Note Voltage connected to V1 required for frequency tracking Communications Ports...

Страница 18: ...ow pass analog filtering Net filtering analog plus digital rejects dc and all harmonics greater than the fundamental Protection and Control Processing Four times per power system cycle Battery Monitor...

Страница 19: ...20 C and at nominal system frequency unless noted otherwise Voltages VA VB VC VS 3V0 V1 V2 0 2 67 300 0 V wye connected Currents IA IB IC 1 A nominal 3 mA 0 1 0 1 20 A Temperature Coefficient 0 0002...

Страница 20: ...laws in its products including without lim itation software firmware and documentation The information in this document is provided for informational use only and is subject to change without notice...

Отзывы: