91
-
Barcode unit / H (horizontal feeding)
Reading direction Horizontal feeding (bar direction is perpendicular to sheet feeding direction)
Codes JAN/EAN/UPC (module 0.33 mm,0.8 times~ 2 times)
NW-7
ITF (Interleaved Two of Five)
CODE-39
CODE-93
CODE-128
EAN-128
Reading area Sheet feeding direction : It depends on sheet size setting.
Refer to Barcode readable area in page 75.
Paper width direction : 20~224mm from sheet edge(timing mark side).
Number of digits to be read Maximum 48 digits
Number of labels to be read Maximum 10 (total number of digits to be read is 200 or less)
Label interval 40mm or more
Barcode printing specifications
• Height 10mm or more
* It requires a starting margin of 12mm or more, and an ending margin of 4
characters or more for a barcode.
• PCS: 0.7 or more
• Bar width (narrow bar) 0.2-2mm
* Bar:space ratio = 1:0.85-1.15
* Recommended N:W ratio = 1:2.5
* There should not be any bleeding, chipping, blank areas, etc.
• Skew: ±3 degree or less from the standard paper feeding edge.
•
Sticking label:
※
1
Reading side Read the top surface of a sheet as it is fed
Directions to adjust reading positions
Paper width direction: manually adjust the head position
Sheet feeding direction:
“Specifying reading start position mode”
Use command to specify reading starting position from
the front edge of a sheet (measurement: mm) and
reading area for a barcode.
“Whole area reading mode”
Entire area of a sheet can be read.
(Barcodes in all areas of the sheet-feeding direction
can be read.)
“SR9000 compatible mode”
Specify barcode reading starting position using timing mark
※
1 entire thickness of label sticking section is 0.25mm or less
Label must not be floated and come off.
Barcode unit / V • barcode unit / H
■
Barcode unit specifications