PoolDose | pH · ORP
0000138981
rev. 1.0 EN
4
5. SETUP INSTRUCTIONS POOLDOSE SYSTEM
Program Setup
–
Press
for 5 seconds
At the entry of each menu item, the parameter can be directly modified using the arrow keys (
and
).
Confirmation of the current setting and switching to the next item is done by pressing the
button.
The menu has a circular structure: once you arrive at last item, the confirmation of the parameter set by
pressing
, determines the return to the first menu item.
1
Language
– It is possible to select between 5 available languages:
EN
, FR, IT, DE, ES
2
Setpoint
–
7.4pH
(5-9pH) /
700mV
(300-900mV)
3
Type
_
dosing
–
Acid
(Acid/Alka) /
Low
(Low/High)
4
Time
_
on
= 30seconds (range from 1 to 360 seconds)
5
Time
_
off
= 60seconds (range from 1 to 360 seconds)
6
Advanced
menu
4.1
Select Measure
– (pH/ORP)
4.2
Circulation
pump
– (Enabled/disabled)
4.3
Temp
.
compensation
– (Auto/Manual 25°C,
range 15…45°C
)
4.4
Temp
.
probe
Calibration
– Reference (PT100 sensor) or Disabled
4.5
OFA
_
OFF
– (0-60min.)
4.6
Input
Flowrate
§
Pulse/ liter 1:1
§
Unit measure m³, l.
4.7
Calibration
§
Two points
§
Single point
§
Referece
4.8
Peristaltic
dosing
type
§
On/Off
§
Timed
§
Prop
§
Off
4.9
Aux
Relay
(Off/On)
1) Button to increase the value
2) Button to decrease the value
3) Button Menu/Esc
4) Button Cal/OK
5) Button to set the setpoint
6) Digital display
* Timed dosing only
1 2 3 4 5
6
Содержание PoolDose ORP