PoolDose | pH · ORP
0000138981
rev. 1.0 EN
11
11. ALARMS
Alarm
Display PoolDose pH
Display PoolDose ORP
Actions to do
Level
TANK Level LOW
-
- Restore Product tank
Measure out
of range
MEASURE TOO LOW
(<6 pH)
MEASURE TOO HIGH
(>8 pH)
MEASURE TOO LOW
(<600 mV)
MEASURE TOO HIGH
(>800 mV)
- Replace or check the
measure probe
- Restore pH / ORP measure
OFA Alarm
(time > OFA
time)
OFA
-
- Push
to reset
Flow Rate
FIlTRATION OFF
-
- Restore Flow Rate
Calibration
Function
Error_______4_pH
Error_______7_pH
calibrat_____ pH7
Error_______700_mV
- Restore Probe or Buffer
solution and repeat
calibration procedure
System Error
Parameters error
- Press
to restore Default
parameter
- Broken Unit
Modbus Error
wdg
- Press
to reset
- Restore communication
Default Parameters
PoolDose pH
PoolDose ORP
Language
EN
Time OFA
OFF
Flow Input
OFF
Set Point value
7.4 pH
700 mV
Calibration
7 pH / 4 pH (2-point)
475 mV
Dosing Method
Acid
Low
Alarm measure:
n
Item
Limits
1
Temp. Measure min
+10°C
2
Temp. Measure Max
+38°C
3
pH Measure min
6 pH
4
pH Measure Max
8 pH
5
ORP Measure min
+600 mV
6
ORP Measure Max
+800 mV
To restore the default parameters, follow the steps below:
•
Power off the PoolDose unit
•
Keep
and
pressed and power on the unit
•
The unit will flash
Init.default__no
•
Press
Init.default__Yes
•
Press
to restore the default parameters.