0000137630 Rev. 2.0 8
Paragraph 5
These items menu are different depending on the
menu
settings:
•
Manual Mode
•
mA Mode
•
PPM Mode
•
1:N Mode
•
N:1 Mode
•
Batch Mode
Case
Manual Mode
:
Pump doses at selected flow rate. If OFF Time is set to 0sec, pump runs continuously.
Pump start dosing after a selectable Delay time.
Ex. Manual Dosing with trigger:
If no trigger is selected, pump start delay counting after power-on.
Programming
Operation
The pump operates in constant mode. The flow can only be
manually regulated by pressing the
keys at the
same time to increase the flow, or the
keys to
decrease it.
Makes it possible to set:
•
ON Time=
Time for which the pump runs.
•
OFF Time=
Time for which the pump is stopped.
•
DELAY Time=
time delay after which the pump
starts to run.
PROG
Configuration
Pump function
Manual Mode
Manual MODE
ON Time sec
Manual MODE
OFF Time sec
Manual MODE
DELAY Time sec
Delay
ON
OFF
Trigger
Dosing
Содержание KRONOS 50
Страница 2: ...0000137630 Rev 2 0 ...