To ensure brightness and safety, carry out periodical cleaning and inspection.
If you find a problem, discontinue the use of the product and have it repaired by a specialist.

Tokyo Branch

Never touch the lamp and its surroundings while the power is on or just after the power is turned off. The lamp and its
surroundings are very hot, so an accidental touch might cause a burn.

Fax

SEIWA ELECTRIC MFG.CO.,  LTD.

Phone

Phone

36 Shinike, Terada, Joyo, Kyoto Pref. 610-0192 Japan

+81 774 55 8181

For further information on the product, contact any of our offices listed below (if you like to make an inquiry, let us know the model name
indicated on the product nameplate).

A lighting fitting has a service life. A product which has been used for eight to ten years may have degraded internal parts
even if it looks normal. For safety and energy saving, we recommend you check and replace it. The LED module design life is
60,000 hours (different from the lighting fitting life) when used at an ambient temperature of 30°C, 10 hours per day, 3,000
hours per year. If used at a higher temperature or more hours per year, the life would be shortened. Have a specialist
inspect the product every three years. If used for an extended period without inspection, a smoke, fire, or electric shock
might result.

If you continue to use the product in an abnormal condition (smoke, odor, etc.), an explosion, a fire or electric shock might
result. If you detect an abnormality, immediately turn off the power switch. Confirm that the abnormal condition has been
eliminated and make a repair call.

Please note that the above addresses and phone numbers may be changed.

  CAUTION

2-19-6 Yanagibashi, Taito-ku, Tokyo 111-0052 Japan

+81 3 5833 8971

For a product marked with a frequency, don

t use the product at a frequency other than 50 or 60 Hz (local power supply

frequency). Use at a wrong frequency might cause a fire.

Fax

Do ’t use the produ t at a  oltage other tha  the rated  oltage i di ated o  the  a eplate.

Otherwise, breakage, fire or electric shock might result.

Any product not marked as a product for outdoor use should not be used outdoors or in a humid place or near a water
source. Its use in such a place might cause a fire or electric shock.

Installation of the product should be carried out by a qualified person.
Installation by an unqualified person is legally prohibited.

The product should be mounted on a surface robust enough to support its weight, properly according to the instruction
manual. Improper installation might cause the product to fall or result in an electric shock or injury.

+81 774 58 2034

+81 3 5833 8946  

Head Office

When leading the power cable into the product through a conduit or the like, waterproof the connection and joint
adequately to prevent water infiltration. Inadequate waterproofing might cause a fire or electric shock.

Don

t use the product in a strong corrosive gas atmosphere which contains hydrochloric acid or chlorine gases or the like.

Use in a corrosive gas atmosphere might cause the product to corrode and fall, resulting in an injury.

直L G13 照

6

   WARNING

- 2/2 -

Содержание LZAB-V2

Страница 1: ...ion pipe A and screw in the terminal box cover Confirm that the O ring is in the groove of the terminal box cover 4 Raise the fitting and fit it to the suspension hardware Hook the suspension hook onto the terminal box Explosion proof type LED Lighting Fittings LZAB V2 Performance IP rating Hazardous Area Usable in Zone 1 or Zone 2 hazardous areas where there are hydrogen gases Type of Protection ...

Страница 2: ...ach other Loosen the reflector fixing screw and open the lamp house gently until it is supported by the chain The lamp house can be opened down to 90 degrees by removing the chain snap from the chain retainer Lead the applicable cable into the fitting through the cable gland and connect the power cable The white and red wires are power wires and the black wire is a grounding wire Pass the lead wir...

Страница 3: ...structure which is vibration free and less susceptible to damage Otherwise it might fall or be damaged The fastening bolts on the control unit chamber housing the control unit have a tensile strength level of A20 70 Don t remove the fastening bolts Removal of the bolts might cause a fire electric shock or explosion The product should be installed at an angle within the range from 0 oriented downwa...

Страница 4: ...e sure to ground For electrical connections use crimp type terminals etc to secure the connections and conduct insulation treatment An inadequate connection or inadequate insulation might cause an imperfect contact leading to an explosion fire or electric shock Be sure to turn off the power In grounding work be sure to follow the technical standards for electrical equipment and explosion protected...

Страница 5: ...abnormality immediately turn off the power switch Confirm that the abnormal condition has been eliminated and make a repair call Please note that the above addresses and phone numbers may be changed CAUTION 2 19 6 Yanagibashi Taito ku Tokyo 111 0052 Japan 81 3 5833 8971 For a product marked with a frequency don t use the product at a frequency other than 50 or 60 Hz local power supply frequency Us...

Отзывы: