background image

When reordering, please let us know:

Drawing or drawing No. for the delivered product

Manufacturing lot number on the nameplate

1.

2. Prior to maintenance or inspection, be sure to turn off the power. 
3. Confirm that the screws and bolts are fastened properly and tightly.
4. In the case of the stanchion type, be sure to provide a support at least 800 mm above the bottom of the pole.
5.

6.

7.

8. The supply voltage variation should be within  ±6% of the rating.
9. Close unused entries of the terminal box with plugs.

10.

11.

12. Prior to maintenance or inspection, be sure to turn off the power.

13. To prevent shortening of the service life, avoid turning on the fitting in direct sunlight.

14. To avoid noise or malfunctioning, don't use a radio, television or wireless infrared remote control near the fitting.

15.

16.

17.

18.

Do ’t ope  the produ t. Otherwise, a  e plosio , fire, or ele tri  sho k  ight result.

19. The cable gland must be a product specified by SEIWA.
20. The LED lamp and the power supply unit cannot be replaced.
21.

Do ’t look straight at the LED la p. It  a  da age  our e es.

Reordering

If the above information is unavailable, give us any material showing the appearance of the
product or details of the product specification (dimensions, mounting interval, lamp type, etc.).

The product must be installed so that the angle of the lamp house is within a prescribed range from its downward oriented position (0°).
If the angle is out of the range, an insulation failure or electric shock might result.

For use in an unfavorable location (a very hot, cold or humid place or a place in which there is strong wind or vibration, a salt damage
environment or a dusty or corrosive gas atmosphere), a special countermeasure should be taken.

The ambient temperature should be within the range of -20°Cto +40°C. The use of the product out of this range may shorten the service
life.

In grounding work, be sure to follow the technical standards for electrical equipment and explosion-protected equipment of your country.
Inadequate grounding might cause an explosion, fire or electric shock.

For white LED lamps, the luminescent color and brightness may vary with individual LEDs because of their nature. Also note that the rate
of attenuation with time varies with individual LED lamps.

The product must be mounted on a sturdy wall surface or structure which is vibration-free and less susceptible to damage. Otherwise, it
might fall or be damaged.

For outdoor use, waterproof the screwed portion of the conduit, the cable entry fittings and the joint with the stand pole to prevent
rainwater infiltration.

When installing the fitting, be sure to connect external wires inside a specified part of the fitting. Don't open any other part of the fitting
unless necessary.

The product must be used in a location where it can be used safely according to its explosion protection type (indicated on the body).

Fig.8 

Nameplate 

CAUTIONS 

-   -

Содержание LKAB07034

Страница 1: ...A 0 19 0 08A 25 5 26W 18 18 5W Stanchion Special direct mount Horizontal pole mount Lamp house replacemen The electrical characteristic data is given below the figure in angle brackets in the Installation Type column is a sign placed at the end of each model code to represent the type of installation Names of the Components and Installation Method Special direct mount Horizontal pole mount Lamp ho...

Страница 2: ...g The lamp house is installed within an angle range from 0 to 70 degrees in the left and right directions For angle adjustment loosen the two hexagon socket head bolts on the retainer After adjustment be sure to tighten the hexagon socket head bolts As shown in Fig 5 put the mounting band onto the support and insert the horizontal pole handrail Lift the lamp house and fix the lamp house mounting b...

Страница 3: ...xisting pipe Attach the protective tube to the connecting member then screw the cover into the body securely Confirm that the cover is invisible from the O ring If visible the waterproofness is not ensured How to Use Maintenance Disassembly and Disposal Separate the cable gland into parts as shown in Fig 7 and pass the cable through the cable gland in the following order cover connecting member ca...

Страница 4: ...ribed range from its downward oriented position 0 If the angle is out of the range an insulation failure or electric shock might result For use in an unfavorable location a very hot cold or humid place or a place in which there is strong wind or vibration a salt damage environment or a dusty or corrosive gas atmosphere a special countermeasure should be taken The ambient temperature should be with...

Страница 5: ...ble for the location Use of an unsuitable type apparatus might cause an explosion or fire The ambient temperature should be within the operating temperature range specified in the instruction manual If the product should be used at a temperature higher than specified an early lighting failure or malfunction might occur or an explosion or fire might result If a product must be oriented in a specifi...

Страница 6: ...lace it The LED module design life is 6 0000 hours different from the lighting fitting life when used at an ambient temperature of 30 C 10 hours per day 3 000 hours per year If used at a higher temperature or more hours per year the life would be shortened Have a specialist inspect the product every three years If used for an extended period without inspection a smoke fire or electric shock might ...

Отзывы: