Stanchion Type (Fig. 2: Example LKAB070351)
NB:
NB:
■
Special Direct Mount Type (Fig. 3: Example LKAB070311)
Connect the electric wires in the terminal box.
NB:
■
Horizontal Pole Mount Type (Figs. 4 and 5: Example LKAB070314)
Connect the electric wires in the terminal box.
Adjust the angle of the lamp house using the mounting bracket.
NB:
Fit the top flange attached to the lamp house into the stand
pole (in the arrow direction).
Tighten the retaining screw and two locking screws supplied
with the top flange and confirm that the lamp house does not
turn.
Pass the electric wires (white and black: power wires, green:
grounding wire) through the flexible fitting and attach the
flexible fitting to the retainer (lamp house).
Pass the electric wires (white and black: power wires, green:
grounding wire) through the stand pole.
Don't remove the waterproof rubber pieces from the
retaining screw and locking screws.
Attach the short nipple and terminal box, referring to the
short nipple installation manual.
For installation of the
terminal box, see Fig. 1.
Completely fix the stand pole with the support (not supplied)
and prescribed terminal box mounting screws.
Bring the electric wires to the terminal box and connect the
wires in the terminal box.
The lamp house should be installed within an angle range
from 0° (down) to 15°.
Fix the mounting bracket on a horizontal mounting surface
securely with M6 bolts or equivalent bolts.
Pass the electric wires through the terminal box and attach
the terminal box to the flexible fitting.
Adjust the angle of the lamp house using the mounting
bracket.
The product is mounted on a ceiling. The lamp house is
installed within an angle range from 0 to 70 degrees in the
left and right directions. For angle adjustment, loosen the
two hexagon socket head bolts on the retainer. After
adjustment, be sure to tighten the hexagon socket head
bolts.
As shown in Fig. 5, put the mounting band onto the support
and insert the horizontal pole (handrail).
Lift the lamp house and fix the lamp house mounting bracket
to the support securely with the two hexagon bolts and two
hexagon nuts on the mounting bracket.
Pass the electric wires (white and black: power wires, green:
grounding wire) through the flexible fitting and attach the
flexible fitting to the retainer (lamp house).
Pass the electric wires through the terminal box and attach
the terminal box to the flexible fitting.
The lamp house is installed within an angle range from 0 to
70 degrees in the left and right directions. For angle
adjustment, loosen the two hexagon socket head bolts on
the retainer. After adjustment, be sure to tighten the
hexagon socket head bolts.
Keeping the support horizontal, fix the mounting band and the
support securely with the pole between them using the two
hexagon bolts and two hexagon nuts on the mounting band.
Stand pole
Support
(not supplied)
Adapter
(thread G3/4)
Short nipple
(w/ 2 O rings)
2-Locking screws
(w/ rubber piece)
Top flange
Retaining screw
(w/ rubber piece)
Lamp house
Terminal box
8
0
0
mm
o
r
mo
re
Fig. 2
Fig.3
2-
φ holes
(for M8 bolts)
Mounting bracket
Retainer
Lamp
house
Terminal box
Flexible fitting
Mounting angle
(up to 70
°
left/right)
2-Hexagon socket head
bolts
Pole (handrail)
Mounting band
(not supplied)
Support
Retainer
Lamp
house
Flexible fitting
Terminal box
2-Hexagon bolts
2-Hexagon bolts
2-Hexagon nuts
Mounting bracket
2-Hexagon nuts
Fig.4
Fig.5
Pole (handrail)
(not supplied)
Support
Mounting band
- -