Lamp House Replacement Type (Fig. 6: Example LKAB037032)

Attach the lamp house to the existing pipe.

Connect the electric wires in the existing junction box.

NB1:

NB2:

Attachment of Cable Gland (Fig. 7: Example ZCGS-22B)

NB1:

NB2:

Screw in the lock nut on the body until it touches the body flange. 

NB: Waterproof the threaded connection.

Fasten the cable retaining plate on the cable fixing member.

NB: Confirm that the cable does not move.

NB1:

NB2: The cable gland should be a product as specified by SEIWA.

The LED lamp is turned on by applying the rated voltage to the power cable of the product.

Inspection

1)

2) Prior to maintenance, be sure to turn off the power.

3) Carry out maintenance properly in accordance with the related law and regulations.

4) If a repair is needed, consult us.

1) In the period when the product is in use, never disassemble it.

2) For disposal of the product, follow the regulations and rules of your local government.

Before attaching the lamp house, check the existing piping (including
the pipe and junction box) for corrosion.

Pass the electric wires (white and red: power wires, black: grounding
wire) through the pipe (existing or supplied pipe) and the existing
junction box.

Tighten the locking screw on the body to prevent the cable
fixing member from loosening.

If the product is used in a place subject to water splashes,
waterproof the connection between the lamp house and the
existing pipe.

Attach the protective tube to the connecting member, then
screw the cover into the body securely.

Confirm that the cover is invisible from the O ring. If visible,
the waterproofness is not ensured.

How to Use

Maintenance

Disassembly and Disposal

Separate the cable gland into parts as shown in Fig. 7 and pass
the cable through the cable gland in the following order:
cover, connecting member, cable fixing member, washer,
rubber sleeve, washer, body, and lock nut.

The cable should be a round cable applicable to the rubber
sleeve. For information on cables applicable to the cable
gland, see the catalog.

Be sure to remove the locking screw on the cable gland
body before separating the cable gland into parts.

Tighten the lock nut toward the terminal box (or the device to
which the gland is to be attached).

In cleaning the fitting, gently wipe with water or mild detergent. Don

t use thinner, benzene or alkaline detergent. Such

chemicals might cause discoloration or deterioration in quality and strength, resulting in a damage.

Fasten the gland onto the entry of the terminal box (or the
device to which the gland is to be attached) until the body
stops.

Push the washer, rubber sleeve, and washer into the body and
pull out the cable to a sufficient length for cable connection.
Screw the cable fixing member into the body.

 Existing junction box 

Existing pipe 

Power cable 

Lamp house 

Fig.6 

Fig.7 

Lock nut 

2-Washers 

O ring 

Terminal box  

Locking screw  

Body 

Rubber sleeve 

Cable fixing member 

2-Cable fixing screws 

Cable retaining plate 

O ring 

Connecting member 

Cable gland (ZCGS)  

Cover 

Cable (round) 

-   -

Содержание LKAB07034

Страница 1: ...A 0 19 0 08A 25 5 26W 18 18 5W Stanchion Special direct mount Horizontal pole mount Lamp house replacemen The electrical characteristic data is given below the figure in angle brackets in the Installation Type column is a sign placed at the end of each model code to represent the type of installation Names of the Components and Installation Method Special direct mount Horizontal pole mount Lamp ho...

Страница 2: ...g The lamp house is installed within an angle range from 0 to 70 degrees in the left and right directions For angle adjustment loosen the two hexagon socket head bolts on the retainer After adjustment be sure to tighten the hexagon socket head bolts As shown in Fig 5 put the mounting band onto the support and insert the horizontal pole handrail Lift the lamp house and fix the lamp house mounting b...

Страница 3: ...xisting pipe Attach the protective tube to the connecting member then screw the cover into the body securely Confirm that the cover is invisible from the O ring If visible the waterproofness is not ensured How to Use Maintenance Disassembly and Disposal Separate the cable gland into parts as shown in Fig 7 and pass the cable through the cable gland in the following order cover connecting member ca...

Страница 4: ...ribed range from its downward oriented position 0 If the angle is out of the range an insulation failure or electric shock might result For use in an unfavorable location a very hot cold or humid place or a place in which there is strong wind or vibration a salt damage environment or a dusty or corrosive gas atmosphere a special countermeasure should be taken The ambient temperature should be with...

Страница 5: ...ble for the location Use of an unsuitable type apparatus might cause an explosion or fire The ambient temperature should be within the operating temperature range specified in the instruction manual If the product should be used at a temperature higher than specified an early lighting failure or malfunction might occur or an explosion or fire might result If a product must be oriented in a specifi...

Страница 6: ...lace it The LED module design life is 6 0000 hours different from the lighting fitting life when used at an ambient temperature of 30 C 10 hours per day 3 000 hours per year If used at a higher temperature or more hours per year the life would be shortened Have a specialist inspect the product every three years If used for an extended period without inspection a smoke fire or electric shock might ...

Отзывы: