20
SHUTDOWN - ANTI-FREEZE FUNCTION
To switch off the timer thermostat press ‘
’.
The display will show the word ‘OFF’ and the ‘
’ symbol.
If the timer thermostat was set in the heating mode, the antifreeze
function will be enabled and the
‘ ‘
symbol will appear on the
display; in such a case the room temperature will be controlled
according to the programmed antifreeze temperature set point.
MANUAL OPERATION
Pressing the
‘ ‘
button will cause the
‘ ‘
symbol to appear
on the display and the timer thermostat will control the room
temperature according to the current comfort mode setting selected
by means of knob
‘ ‘
, 24 hours a day, irrespective of the position
of the dipswitches.
To revert to operation according to the set daily program, press
‘ ‘
again.
TEMPERATURE / TIME DISPLAY
By repeatedly pressing the key ‘
‘ the display cycles on showing
the current time, the room temperature measured by the internal
sensor, explained with the icon ‘
‘, and the room temperature
measured by the remote sensor (if wired) explained with the icon
‘
‘.
The values of temperature displayed are shown adjusted with the
set Offset value.
In case the parameter ‘
rEG
‘ is set on ‘
EHt
‘ but the remote
sensor is not wired or is broken the display will show the words
‘
SEnS OPEN
‘ or ‘
SEnS SHrt
‘ with the icon ‘
‘ turned on.
When an electro-thermal actuator is wired to the output, this
parameter must be set with the actuator’s travel time, otherwise
‘on’ pulses of a lower time respect to the travel time would generate
unuseful output actions.
The parameter can be set in the range 3 .. 15 minutes.
The device leaves the factory with parameter set on 3 minutes.
‘
dFLt
’ SET DEFAULT DATA
With this parameterit ispossible to resetuser parametersin order
tobring back all theparameters to thefactory defaults.
Proceed as follows:
1.
Select the parameter ’
dFLt
’ and press ’
OK
’; the device
automatically sets the default data and the display will show
‘
-dF-
‘.
2.
To quit the user parameter settings press the ‘
OK
’ button or wait
10 seconds without pressing any key.
3.
To reset the normal operation press the ‘
’ button.
WARNING!
Restoring the Default Data will reset all settings made by the
user, such as Time Program, Heating/Cooling, Set-Points and
all other programmable data.
ITALIANO
DEUTSCH
FRANÇAIS
ESPAÑOL
PORTUGUÊS
ENGLISH