RYM02M0000SE 034674 220520
11
- ITALIANO -
A
T
EX
-
D
O
C
U
M
EN
T
O
C
O
R
R
EL
A
T
O
-
C
O
PI
A
C
O
N
F
O
R
M
E
A
L
L
’O
R
IG
IN
A
L
E
-
Q
U
A
L
U
N
Q
U
E M
O
D
IF
IC
A
A
L
PR
ESEN
T
E
D
O
C
U
M
EN
T
O
R
IC
H
IED
E L
’A
U
T
O
R
IZ
Z
A
Z
IO
N
E D
EL
R
ESP
O
N
S
A
B
IL
E
A
Z
IEN
D
A
L
E PER
L
A
D
O
C
U
M
EN
T
A
Z
IO
N
E
A
T
EX (
R
T
).
A
T
E
X
-
L
IN
K
ED
D
O
C
U
M
EN
T
-
C
O
PY C
O
M
PL
IA
N
T
W
IT
H
O
R
IG
IN
A
L
-
A
N
Y C
H
A
N
G
E T
O
T
H
IS D
O
C
U
M
EN
T
R
EQ
U
IR
ES PR
IO
R
A
PPR
O
V
A
L
F
R
O
M
T
H
E R
ESPO
N
SI
B
L
E
F
O
R
A
T
E
X
D
O
C
U
M
EN
T
A
T
IO
N
(
R
T
).
EVENTO
RELE’
PREALARM
RELE’
ALARM 1
RELE’
ALARM 2
RELE’
AUX 1
RELE’
AUX 2
LED
LED
LED
LED
BUZZER
Fault centralina
AC
AC
Fault
trasmettitore
AC
AC
Over Range
AC
AC
Allarme 2
AC
AC
Allarme 1
AC
AC
Preallarme
AC
AC
Riscaldamento
dei trasmettitori
Nessun allarme
Open Loop
AC
AC
Fine vita sensore
AC
AC
Test uscite
Nella tabella vengono riportati gli eventi che possono determinare l’attivazione dei relè di uscita e delle segnalazioni ottico-acustiche.
LEGENDA
:
ATTENZIONE
- In presenza di più eventi contemporaneamente, visivamente verranno mostrate le indicazioni in base alla priorità degli eventi
stessi; ad esempio se contemporaneamente si verifica un evento di Preallarme e di Allarme 1, la centralina mostrerà l’evento
di Allarme 1.
L’ordine delle priorità è descritto nel paragrafo “Priorità eventi anomali”.
- Il led
sarà sempre acceso solo nel caso in cui la centralina venga alimentata dalla tensione di rete.
- Il led sarà acceso ad indicare che la logica della centralina è in funzione. In caso contrario, indica una alimentazione
insufficiente.
Relè spento - Led spento - buzzer spento
Relè attivato
-
Led acceso
(con luce fissa) -
buzzer acceso
con suono continuo.
AC
Relè attivato in modo condizionato
; il relè può essere attivato solo se è stata impostata correttamente l’uscita ausiliaria
(vedere menu SYST - ‘Mode Aux1’ e ‘Mode Aux2’).
Led lampeggiante
-
buzzer acceso in modo intermittente
.
──────────────────────────────────────────────────────────────────────────────────────────────────────
[u] CONDIZIONI DI ATTIVAZIONE DEI RELE’ DI USCITA, DEI LED E DEL BUZZER
──────────────────────────────────────────────────────────────────────────────────────────────────────
- Password:
0000
- Allarmi memorizzati: Nessuno
- Zone activation:
Zone 1 active
= Y
Zone 2 active
= Y
Zone 3 active
= N
Zone 4 active
= N
Zone 5 active
= N
Zone 6 active
= N
Zone 7 active
= N
Zone 8 active
= N
- Zone gas type:
Zone 1 type
= CH4 (Metano)
Zone 2 type
= CH4 (Metano)
Zone 3 type
= CH4 (Metano)
Zone 4 type
= CH4 (Metano)
Zone 5 type
= CH4 (Metano)
Zone 6 type
= CH4 (Metano)
Zone 7 type
= CH4 (Metano)
Zone 8 type
= CH4 (Metano)
- Zone full scale:
Zone 1 fs
= 50% (L.E.L.)
Zone 2 fs
= 50% (L.E.L.)
Zone 3 fs
= 50% (L.E.L.)
Zone 4 fs
= 50% (L.E.L.)
Zone 5 fs
= 50% (L.E.L.)
Zone 6 fs
= 50% (L.E.L.)
Zone 7 fs
= 50% (L.E.L.)
Zone 8 fs
= 50% (L.E.L.)
- Zone prealarm:
Zone 1 pre
= 10% (L.E.L.) / 16 ppm
Zone 2 pre
= 10% (L.E.L.) / 16 ppm
Zone 3 pre
= 10% (L.E.L.) / 16 ppm
Zone 4 pre
= 10% (L.E.L.) / 16 ppm
Zone 5 pre
= 10% (L.E.L.) / 16 ppm
Zone 6 pre
= 10% (L.E.L.) / 16 ppm
Zone 7 pre
= 10% (L.E.L.) / 16 ppm
Zone 8 pre
= 10% (L.E.L.) / 16 ppm
- Zone alarm 1:
Zone 1 al1
= 20% (L.E.L.) / 80 ppm
Zone 2 al1
= 20% (L.E.L.) / 80 ppm
Zone 3 al1
= 20% (L.E.L.) / 80 ppm
Zone 4 al1
= 20% (L.E.L.) / 80 ppm
Zone 5 al1
= 20% (L.E.L.) / 80 ppm
Zone 6 al1
= 20% (L.E.L.) / 80 ppm
Zone 7 al1
= 20% (L.E.L.) / 80 ppm
Zone 8 al1
= 20% (L.E.L.) / 80 ppm
- Zone alarm 2:
Zone 1 al2
= 30% (L.E.L.) / 150 ppm
Zone 2 al2
= 30% (L.E.L.) / 150 ppm
Zone 3 al2
= 30% (L.E.L.) / 150 ppm
Zone 4 al2
= 30% (L.E.L.) / 150 ppm
Zone 5 al2
= 30% (L.E.L.) / 150 ppm
Zone 6 al2
= 30% (L.E.L.) / 150 ppm
Zone 7 al2
= 30% (L.E.L.) / 150 ppm
Zone 8 al2
= 30% (L.E.L.) / 150 ppm
- Mode aux 1:
Aux 1 pre
= N
Aux 1 al1
= Y
Aux 1 al2
= Y
Aux 1 flt
= Y
Aux 1 opn
= N
Aux 1 ovr
= N
- Mode aux 2:
Aux 2 pre
= N
Aux 2 al1
= N
Aux 2 al2
= N
Aux 2 flt
= Y
Aux 2 opn
= N
Aux 2 ovr
= N
- Relay latch:
Latch aux1
= Y
Latch aux2
= Y
Latch pral
= N
Latch alr1
= Y
Latch alr2
= Y
- Relay start:
Start aux1
= N
Start aux2
= N
- Relay logic:
Logic aux1
= R
Logic aux2
= R
Logic pral
= N
Logic alr1
= N
Logic alr2
= N
- Change Time/Date: dd/mm/yy hh:mm = Da Impostare
Summer Time
= Auto
- Buzzer setup:
Buzzer enable
= Y
──────────────────────────────────────────────────────────────────────────────────────────────────────
[v] IMPOSTAZIONI DI FABBRICA
──────────────────────────────────────────────────────────────────────────────────────────────────────